4.
Start the mower and in particular hydraulic drive, smoothly changing rpm.
5.
Use bolts
S
2,
to adjust by locking bolts
S
1
each time – perform these until there are no more
bulges on the belt.
NOTE:
Precision is recommended, so belts and their edges worked symmetrically on
rollers. Well-adjusted belt cannot be bulged in places where v-belt is guided
inside the roller channel.
7.
LUBRICATION
7.1.
Cutterbar
Cutterbar is filled with oil through plug closed hole
A
(
Fig. 46
). Adequate oil level with
horizontal position of the cutterbar is 5÷7 mm from the cutterbar's bottom. In order to drain oil from
the cutterbar dismount the cutterbar enclosure by releasing bolts (
B
). The best time to drain the oil
is immediately after the operation, if still warm. Amount of oil to be filled is provided in
table
9
.
Fig. 46.
Points of oil inspection and replacement in cutterbar
Tab. 9.
Amount of oil to be filled in cutterbar
Mower type
Oil volume
[L]
Oil type
Replacement frequency
KDC – 2,60 m
5,0
80W90
After first 50 h of operation and
then after next 500 h (or at least
once a year)
KDC - 3,00 m
6,0
KDC – 3,40 m
6,5
KDC – 3,90 m
7,0
KDC – 4,30 m
2 x 4,5
7.2.
Intersecting axis gears
Prior to operation (e.g. some more demanding a task) firstly examine oil level and if need be
refill it once air vent is taken out
A
in upper section of the gear (
Fig. 47
). Oil level is inspected by
opening check plug
B
on the side of the gear. If oil level is too low, refill oil until it is visible in the
check opening. Oil level in gear: approx. 1 litre. Plug
C
is used to drain oil.
Tab. 10.
Amount of oil to be filled in gear
Mower type
Oil volume
[L]
Oil type
Replacement frequency
All types
approx. 1
SAE 80W/90, API GL-4
After first 50 h of operation and
then after next 500 h (or at least
once a year)
NOTE:
The above provisions should be strictly kept. If discs found on the cutterbar
are able to move freely, then high temperature of axis gear should not be a
point of concern, as in result of a long-term operation it may reach 60-80°C.