SAM4S NR-500 Series Manual
Service Mode Programming • 105
Restore Program from the SD Card
CAUTION: Memory allocation must be set the same as the saved program. Be
sure to print out the memory allocation so that it can be re-entered before restoring
the program.
1.
Set the store name to match the name of the store folder you wish to restore.
2.
Insert the SD card in the register’s SD slot.
3.
Move to the
SERVICE MODE
.
4.
From the Service Mode menu , select “
7.PROGRAM BACKUP
”.
5.
From the PROGRAM BACKUP menu select “
1.SD
”.
6.
From the SD menu select “
2.PGM RESTORE
”.
7.
The register will display confirmation of the successful restoration with the
message “SUCCESS !”. If the save is unsuccessful, the register will print an error
message.
Saving Reports to an SD Card
The SD card can also be used to save reports. Reports saved are the current X1 readings.
SD Report Notes
1.
When backing up and restoring data, the store name must be programmed on
page
160
of “Store Name” in the “SYSTEM” of "
Options Programming
".
The default store name is “STORE001”.
2.
The NR-500 Series will write the program files to folder. For example:
NR-500/STORENAME/SALEBACK/CSVBACK/DATE/TIME or
NR-500/STORENAME/SALEBACK/REPBACK/DATE/TIME or
The date folder depends on date format option. See "
SYSTEM
" of "
Options
Programming
" in the "
Program Mode Programming
" chapter to set DATE
FORMAT.
DATE FORMAT
DATE FOLDER NAME
YYMMDD 20140403
DDMMYY 03042014
MMDDYY 04032014
3.
Each individual report is named with the time of the report. For example
“CLK02332” represents a Clerk report taken at 23:32 (in a 24-hour time
format.) In this manner, multiple reports backed up at different times in the
same day will collect in the same “date” folder.