5.5.4 Log Field Descriptions
Log Field
Description
SN=
The module’s unique serial number.
OS_VERSION=
The operating system version.
BUILD_NUMBER=
The software build number.
HARDWARE_VERSION
The hardware build version.
UPTIME=
Shows the time since the last restart (format
ddd:hh:mm:ss).
LICENSED_OPTIONS=
The licensed features installed in the module.
ROL_STATES=
The status of any RollTracks that have been enabled.
REAR_ID=
The rear panel type.
REAR_STATUS=
The status of the rear panel.
SLOT_WIDTH=
The number of slots used by rear and module.1 or 2.
SLOT_START=
The first slot number the rear occupies. Use in
conjunction with SLOT_WIDTH to determine the slots
that the unit occupies.
LAST_RECALLED_MEMORY=
The last recalled memory.
POWER USAGE=
The power rating for the module. Note: this is not a live
power reading.
INPUT_
N
_IDENT=
The identifier of the serial data input.
INPUT_
N
_NAME=
The name of the serial data input.
INPUT_
N
_TYPE=
This displays the type of input as specified by the unit’s
configuration. Valid values are HD /SD SDI.
INPUT_
N
_STATE=
Displays the current input state. Valid values are:
•
OK
•
WARN:Mismatch
•
FAIL:Lost
•
FAIL:Error
Note: WARN:Mismatch indicates that the input and
output standards are not the same.
INPUT_
N
_SDIRATE=
The current bit rate for the serial data input.
SFP_
N
_TYPE=
The transmitter type.
SFP_
N
_STATUS=
The status of the SFPs as reported by the SFPs.
SFP_
N
_CONNECTOR=
The physical connector type, for example, Fiber LC.
OUTPUT_
N
_TX_POWER_STATE=
Displays the TX power status. Valid values are:
•
OK
•
WARN:HI
•
WARN:LO
•
FAIL:LO
•
FAIL:HI
OUTPUT_
N
_TX_POWER=
The power level of the TX input, in dBm.
OUTPUT_
N
_WAVELENGTH=
The wavelength of the transmitted output signal.