IQFDA31

Operation Using the RollCall Control Panel

Issue 1 Rev 1

Page 12

© 2016 SAM

5

Operation Using the RollCall Control Panel

5.1 Information Window

The Information Window is displayed in the upper-right corner of each screen and displays 
basic information about the input and output status of the module.

5.1.1 Unit Status

The Unit Status pane provides basic information about the status of the video inputs, video 
outputs, product settings, and status.

5.1.2 SFP Status

Note:

The IQFDA31 will dynamically configure itself depending on rear and SFP options. The 
RollCall control panel will change to reflect the current product configuration.

The screens shown in this section are for guidance and reference only, and may be slightly 
different to those on your module.

Name

Description

IN1:
IN2:

Displays the status of Input 1 and Input 2, the detected 
rate, and whether the signal is locked or in bypass mode. If 
no valid input is detected, asterisks (**) are displayed.

OUT:

The first line represents the outputs (1–4). The second line 
is character aligned with the first and indicates the input 
routed to that output. If no valid input signal is detected for 
the output, an E is displayed.

Name

Description

Type:

Shows the type of SFP installed. This is supplemented 
with a simple report for each SFP.

Status:

Shows the operational status of the SFP.

Connector:

Shows the physical connector type, for example, Fiber LC.

Содержание IQFDA31

Страница 1: ...www s a m com User Manual IQFDA31 Dual Channel 3G HD SD SDI Re clocking Distribution Amplifier with Fiber I O ...

Страница 2: ... authorized agents Reproduction or disassembly of embedded computer programs or algorithms prohibited No part of this publication can be transmitted or reproduced in any form or by any means electronic or mechanical including photocopy recording or any information storage and retrieval system without permission being granted in writing by the publishers or their authorized agents SAM operates a po...

Страница 3: ... 5 1 2 SFP Status 12 5 2 Input 13 5 2 1 Input 1 and 2 13 5 2 2 Outputs 13 5 3 SFP 14 5 3 1 SFP Transmit 14 5 3 2 SFP Receive 14 5 4 Memory 1 16 15 5 4 1 Recall Memory 15 5 4 2 Save Memory 15 5 4 3 Last Recalled Memory 15 5 4 4 Save Memory Name 16 5 5 Logging 17 5 5 1 Logging Misc 17 5 5 2 Logging Inputs 17 5 5 3 Logging SFP 18 5 5 4 Log Field Descriptions 19 5 6 RollTrack 21 5 6 1 Disable All 21 5...

Страница 4: ... routing of inputs and outputs allows the module to operate as a single or dual channel mixing fiber and copper I O Input signal loss detection enables switching from a main feed to a back up feed automatically providing emergency changeover functionality Its 80m 3G 170m HD and 300m SD input equalization performance and non re clocking distribution of wide band signals make it ideal for all distri...

Страница 5: ...DVB ASI SMPTE 297 2006 1310 nm 1550 nm and CWDM output wavelengths available RollCall monitoring allows all signal paths to be managed 1 4 Order Codes The following product order codes are covered by this manual The following SFP modules are available for this product 1 5 Rear Panel View Note Modules with A order codes for example IQFDA3100 1A3 can only be fitted into A style enclosures Modules wi...

Страница 6: ... P Enclosure order codes IQH3A E 0 IQH3A E P IQH3A 0 0 IQH3A 0 P Enclosure order code IQH1A S P Important Although IQ modules are interchangeable between enclosures their rear panels are enclosure specific An IQH3B enclosure accepts modules with either A or B order codes An IQH3A or IQH1A enclosure accepts modules with A order codes only See page 5 Note The IQH3B enclosure provides two internal an...

Страница 7: ...E 297 2006 SMPTE 424M HD level A B SMPTE 292M HD SMPTE 259M C SD Signal Outputs SDI Outputs Up to 12 group selectable Connector Format BNC 75 Ohm panel jack on standard SAM connector panel Conforms to video standards SMPTE 297 2006 SMPTE 424M HD level A B SMPTE 292M HD SMPTE 259M C SD Fiber Signal Output SDI Outputs Up to 2 selectable per channel Optical 3 Gbit s HD SDI 1 485 Gbit s HD SDI 270 Mbi...

Страница 8: ... 1 2 Present Input 1 2 Error Input 1 2 Loss Optical Logging Tx Laser Bias High Warning Tx Power Low Warning Tx Power High Warning Laser Wavelength Input 1 2 Rx Power High Warning Input 1 2 Rx Power Low Warning Input 1 2 Rx Power Measurement RollTrack Index Up to 16 RollTrack destinations RollTrack Controls On Off Index Source Address Command Status Sending Roll Track Sources Unused Input Present 1...

Страница 9: ...tput Power 0 to 5 dBm 2 dBm typical Rise and Fall Time 135 ps 3 Gbit s 270 ps 1 5 Gbit s 1 5 ns 270 Mbit s Extinction Ratio 7 5 1 typical Optical Return Loss 27 dB Link Distance Up to 30 Km 3 Gbit s Up to 21 Km 1 5 Gbit s Up to 10 Km 270 Mbit s Optical Rx Input Wavelength Range 1260 nm min 1620 nm max Input Sensitivity 21 dBm Optical Power Input Range 0 dBm 20 dBm Link Distance Up to 30 Km 3 Gbit ...

Страница 10: ...ut connections provided by the IQFDA31 3 1 SDI Input 3 2 SDI Outputs 3 3 SFP Serial digital input is made to the unit via two BNC connectors which terminate in 75 Ohms Serial digital outputs from the unit are made via four BNC connectors which terminate in 75 Ohms An SFP cage provides a range of connectivity options ...

Страница 11: ...clocked That is in re clock bypass mode ERR Red Illuminated Unknown or no input on input channel 1 RATE Green Illuminated The rate on input channel 1 Both LEDs illuminated 3 Gbit s Left LED illuminated 1 5 Gbit s Right LED illuminated 270 Mbit s Both LEDs off Rate unknown SFP Green Illuminated Input SFP Rx A selected CHANNEL B OK Green Illuminated Input channel 2 is locked to the input signal WARN...

Страница 12: ...to reflect the current product configuration The screens shown in this section are for guidance and reference only and may be slightly different to those on your module Name Description IN1 IN2 Displays the status of Input 1 and Input 2 the detected rate and whether the signal is locked or in bypass mode If no valid input is detected asterisks are displayed OUT The first line represents the output...

Страница 13: ...it will re clock 3G 3 Gb signals Others When selected signals that are not of any of the above rates will be re clocked Reclock Bypass When selected the unit will not re clock the input signal If a supported rate is detected the Unit Status will display the detected rate otherwise will be displayed Input Select Use the radio buttons to select the input 5 2 2 Outputs Use the radio buttons to specif...

Страница 14: ...FAIL HI Tx Power Displays the signal level of the transmitted output signal in dBm Tx Wavelength Displays the wavelength of the transmitted output signal either 1310 nm or 1550 nm Laser Bias Displays the bias level in mA Laser Bias State Displays the bias state options include OK WARN HI WARN LO FAIL LO and FAIL HI 5 3 2 SFP Receive For an SFP receiver channel the SFP reports the status of the SFP...

Страница 15: ... 5 4 2 Save Memory This column lists the 16 pre set memory names that are available for use To save settings In the Save Memory column select a memory location and then click Save The current settings are saved and the memory appears in the Recall Memory column To clear a memory location In the Save Memory column select a memory location and then click Clear The current settings stored for that me...

Страница 16: ...Memory Name This option enables the pre set memory names to be changed to something more memorable or meaningful if required To change a memory name In the Save Memory Name field type the new memory name and then click the S button To return the memory to its default preset value click P button ...

Страница 17: ... columns Log Enable Select the check boxes that correspond to the parameters for which log information should be collected Log Field Displays the name of the logging field Log Value Displays the current log value 5 5 1 Logging Misc The Logging Misc screen displays the current log information about the unit s basic parameters 5 5 2 Logging Inputs The Logging Inputs screen is used to select which fi...

Страница 18: ...IQFDA31 Operation Using the RollCall Control Panel Issue 1 Rev 1 Page 18 2016 SAM 5 5 3 Logging SFP The Logging SFP screen is used to select which fields should be enabled for each of the SFP inputs ...

Страница 19: ..._MEMORY The last recalled memory POWER USAGE The power rating for the module Note this is not a live power reading INPUT_N_IDENT The identifier of the serial data input INPUT_N_NAME The name of the serial data input INPUT_N_TYPE This displays the type of input as specified by the unit s configuration Valid values are HD SD SDI INPUT_N_STATE Displays the current input state Valid values are OK WARN...

Страница 20: ...OUTPUT_N_LASER_BIAS The bias level in mA OUTPUT_N_LASER_BIAS_STATE Displays the laser bias status Valid values are OK WARN HI WARN LO FAIL LO FAIL HI Log Field Description Note N should be replaced with the respective SFP output identifier for example 1 for an SFP and B for an output ...

Страница 21: ...ion of data to be selected Dragging the slider selects the RollTrack source displayed below the slider Clicking the P button selects the default preset value When no source is selected Unused is displayed Unused No RollTracks sent Input N OK Valid serial data input received Input N None No serial data input received Input N Bitrate 270 Received bitrate is 270 Mbit s Input Bitrate 1 5 Received bitr...

Страница 22: ...to save the selection Clicking the P button returns to the default preset command The RollTrack command consists of two sets of numbers for example 84 156 The first number 84 is the actual RollTrack command The second number 156 is the value sent with the RollTrack command 5 6 6 RollTrack Sending A message is displayed here when the unit is actively sending a RollTrack command Possible RollTrack S...

Страница 23: ...he Printed Circuit Board revision number Rear Type The rear panel type Licensed Options The installed licensed options 5 7 1 Default Settings The Default Settings button enables module settings to be reset to their factory defaults leaving user memories intact 5 7 2 Factory Defaults The Factory Defaults button enables the module settings to be reset to their factory defaults 5 7 3 Restart The Rest...

Страница 24: ... to be rebooted simulating a power down power up cycle 5 8 2 Configure Type In the event of the module not recognizing the SFP the Configure Type controls will become available for manual selection Note The SFP Setup screen is only displayed when the module is fitted with a rear that supports SFPs even if no SFP is fitted Note When changing an SFP the module needs to be restarted in order for the ...