IQFDA31
Operation Using the RollCall Control Panel
Issue 1 Rev 1
Page 13
© 2016 SAM
5.2 Input
The Input screen enables the inputs and outputs to be configured, and can be used to
determine how the module behaves in the event of an input error.
5.2.1 Input 1 and 2
•
SD/DVB-ASI (270 Mb):
When selected, the unit will re-clock SD/DVB-ASI (270 Mb)
signals.
•
HD (1.5 Gb):
When selected, the unit will re-clock HD (1.5 Gb) signals.
•
3G (3 Gb):
When selected, the unit will re-clock 3G (3 Gb) signals.
•
Others:
When selected, signals that are not of any of the above rates will be
re-clocked.
•
Reclock Bypass:
When selected, the unit will not re-clock the input signal. If a
supported rate is detected, the Unit Status will display the detected rate, otherwise, ***
will be displayed.
•
Input Select:
Use the radio buttons to select the input.
5.2.2 Outputs
Use the radio buttons to specify the input for each of the outputs.
Select
Mute On Inp Err
to apply a mute to the output if any rate other than those specified as
valid in the Input 1 and Input 2 sections is detected.
Select
Mute
to manually apply a mute to the output.