7.
Errors and remedies
If faults should occur, check them using the following table:
Fault
Cause
Remedy
The pilot light does not
light.
On-site gas tap is closed
Open the on-site gas tap.
Pilot burner dirty
Clean pilot burner.
The pilot light goes out af
ter the gas control is re
leased.
The gas control was not
pressed in for a long enough
period.
Press gas control for approx.
5 - 10 seconds so that the
thermocouple is sufficiently
heated and the gas supply is
not interrupted.
Thermocouple contaminated
Clean the thermocouple.
Thermal element defective.
Contact customer service.
If the fault cannot be rectified:
.
Press the gas control and turn to "Off" (Symbol●).
.
Close the customer gas tap.
.
Do not open the housing.
.
Contact customer service.