6
How it Works
Warm water enters the tank and the Col-
lector pump recirculates water down the
trough and if equipped, through the op-
tional gusher heads.
As dishes are scrapped in the recirculated
water in the trough or passed through the
water plume of the gusher heads, they are
scrapped and pre-rinsed at the same time
while soluble food waste washes through
the holes in the scrap basket and into the
tank reservoir.
Insoluble and fibrous food waste is re-
tained in the scrap basket for disposal.
Troubleshooting
WARNING! DISCONNECT THE POWER TO THE SYSTEM BEFORE SERVICING.
IMPORTANT!
Do NOT use corrosive chemicals for scrapping or cleaning purposes!
PROBLEM
POSSIBLE CAUSE
SOLUTION
Tank will not fill up.
Only cold or hot water is
going into tank.
Pump motor not
running.
Water leaks from pump.
Water flow down trough
is very slow or Collector
is not pumping water.
Drain open.
Valves are closed.
Hot or cold valve closed.
Blender is out of adjustment.
Water connections reversed.
Overload tripped.
Contactor not energized.
Pump seal/o-ring broken.
Clamps loose.
Clogged pump.
Clogged pump intake screen.
Pump motor running backwards.
Recirculation valve turned down.
Install overflow pipe.
Open valves.
Open valves.
Adjust setting of blender.
Correct water connections.
Wait for overload to reset and check for cause of
reset to trip, i.e. debris in pump.
Check contactor connections.
Replace seal/o-ring.
Tighten clamps
Open pump and remove debris.
Clean screen.
Reverse rotation of pump.
Adjust valve.
This troubleshooting guide is to provide basic checks to facilitate problem isolation and repair.