background image

AKL04P Zone Pump Wiring Center

 

Installation and Wiring Guide

AUX

XX

ZONE1 E/S

TRANSFORMER

L

N

GROUND

L

N

PUMP2

L

N

PUMP3

L

N

PUMP4

L

N

PUMP5

L

N

PUMP6

L

N

PRIMARY

PUMP

L

N

120 VAC 
OUTPUT

24V - T-STAT 1

24V -T-STAT 2

24V -T-STAT 3

24V -T-STAT 4

MASTER

PRIORITY ON

EXERCISE ON

PRIMARY STATUS DURING PRIORITY ON

PURGE ON

SLAVE

OFF

OFF

OFF

OFF

POWER

PRIMARY

ZONE 1
ZONE 2
ZONE 3

ZONE 4

Group 1 thermostats

G1 (1-2)

Group 2 thermostats

G2 (3-4)

120   VAC

For PDF Installation guide go to www.salus

inc

.com

These instructions apply to the SALUS model stated above.

Warning

This product must be 

fi

tted by a competent person, and installation must 

comply with the  guidance, standards and regulations applicable to the 

country or state where the product is installed. Failure to comply with the 

requirements of the relevant guidance, standards and regulations could 

lead to injury, death or prosecution. 

Warning

Always  isolate  the  AC  main  supply  before  installing  or  working  on  any 

components that require 120 V AC 60Hz supply.

The  ground  terminals  on  the  AKL04P  are  for  ground  connections  only. 

These terminals provide no earth protection.

120VAC TO  PUMP Cables will 
be supplied by the installer.

Maintaining a policy of continued product development SALUS Controls plc reserves the right to change 

speci

fi

cation, design and materials of products listed on this installation guide without prior notice.

Issue Date: Feb 2017   

www.salus

inc

.com  

     

Technical Helpline 1-

855

-

557

-

2587

H

N

H

N

R

W

C

H

N

R

W

C

H

N

R

W

C

H

N

R

W

C

H

1-2

3-4

C1

C2

NSB 1-2/3-4

COMMS

A

R

G1

G2

H

N

H

N

H

N

BOILER

L

Line voltage 120VAC

Neutral  
Ground 
Night Set Back

Switch live output (0-24VAC)            

Fuse 

5 Amp Slow blow

AUX 

Auxiliar, Dry contact

XX 

Dry contact  

Zone1 E/S 

Dry contact 

C1 

           Communication Connections

C2

Communication Connections

Electrical connections

FUSE  5A 

SL

OW  BL
OW

FUSE  5A 

SL

OW  BL
OW

FUSE  5A 

SL

OW  BL
OW

FUSE  5A 

SL

OW  BL
OW

FUSE  5A 

SL

OW  BL
OW

POWER IN

GROUND

PRIORITY

PUMP1

H/R

 

Hot 24VAC

   /W 

                Switch live output (0-24VAC)

N/C 

Return  24VAC
Night Set Back 

Electrical  connections  for 

24VAC thermostats

Zone1 E/S 

PRIORITY

ZC

N