background image

Declarations of Compliance 

 
United States 

This equipment has been tested and found to comply with the limits for a class A digital device, pursuant to Part 
15 of the FCC Rules.  These limits are designed to provide reasonable protection against harmful interference 
when the equipment is operated in a commercial environment.  This equipment generates, uses, and can radiate 
radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause 
harmful interference to radio communications.  Operation of this equipment in a residential area is likely to cause 
harmful interference in which case the user will be required to correct the interference at his own expense. 
 

Canada 

This digital apparatus does not exceed the Class A limits for the radio noise emissions from digital apparatus set 
out in the Radio Interference Regulations of the Canadian Department of Communications. 
 
Le présent appareil numérique n’émet pas de bruits radioélectriques dépassant les limites applicables aux 
appareils numériques de la Classe A prescrites dans le Règlement sur le brouillage radioélectrique edicté par le 
ministère des Communications du Canada. 

 
 
 

 
 

Manufacturer Salter 

Brecknell 

Type S100 

Corresponds to the requirements of the following EC directives:- 

Electro Magnetic Compatibility Directive: 
Low Voltage Directive: 

EMC 89/336/EEC 

LVD  73/23/EEC 

The application harmonised standards are: 

EN60950                              

EN50081-1                            
EN50082-1 

 
 
A copy of the original signed declaration for this instrument is available from the UK address below. 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Contact Information & Technical Support  

 
 

 

 

 
 
 
 

UK and Europe

Salter Brecknell Weighing

P.O. Box 9533, Smethwick,

West Midlands,    B66 2TE.

United Kingdom.

Tel:  +44 (0) 870 444 6132
Fax: +44 (0) 870 010 2241

email:[email protected]

www.salterbrecknell.co.uk

USA

Salter Brecknell Weighing Products USA

1000 Armstrong Drive

Fairmont

MN 56031

Toll Free: 800-637-0529

Phone: 507-238-8702

Fax: 507-238-8271

email:[email protected]

www.salterbrecknell.com

 

 

Declaration of Conformity 

Содержание SBI-100

Страница 1: ...Model SBI 100 Operation Manual Manual xxxxxx Issue xx...

Страница 2: ...DOUBT SEEK ADVICE FROM A QUALIFIED ELECTRICIAN Routine maintenance To avoid the possibility of electric shock or damage to the machine always switch off the machine and isolate from the power supply...

Страница 3: ...pecifications 15 Error Messages 15 Declarations of Compliance 16 Contact Information Technical Support 16 Product Identification Table Part Number Capacity Region Power Supply s 816965001620 75 kg x 0...

Страница 4: ...t Power Adapter Socket Power Supply Connecting the Indicator to the Platform 6VDC 500mA 230V 50Hz Wire the cable attached to the base as shown if necessary 4 2 3 1 1 RED 2 RED 3 RED 4 RED 1 Red Excita...

Страница 5: ...0 Weight is zero On Off Zero On Off Zero kg lb Unit of measure Flashing LED means that the weight reading is not stable Units kg lb Unit of measurement NET Tare is activated Hold Print Hold Print CH B...

Страница 6: ...tion Turning On and Zeroing the Scale On Off Zero ZERO 0 Turning off the scale On Off Zero Selecting Unit of Measure Units kg lb kg lb Using the Tare 1 2 Tare NET 3 NET 4 NET Removing the Tare On Off...

Страница 7: ...old function with manual release This function needs to be setup in Parameter P3 1 shown on page 10 1 Hold Print Hold 2 3 Removing Hold Hold Print Hold Print Function For communications to a printer o...

Страница 8: ...s Hold Print Entering setup On Off Zero Units Selecting parameter Tare Changing data within the parameter Units Saving data Tare Exiting setup On Off Zero ZERO 0 kg Moves flashing digit Units Change f...

Страница 9: ...ctable hold window from 3 to 50 divisions Will hold display reading once stable within a selectable weight range to release the hold button must be represses P3 0 P3 1 P3 2 P3 3 to 50 P4 x RS232 Seria...

Страница 10: ...tare LF H1H2H3 CR ETX U CR Changes the units LF u1u2 CR LF H1H2H3 CR ETX L CR Activates the hold function LF H1H2H3 CR ETX X CR Switches off the scale Indicator switches off Unrecognised command LF CR...

Страница 11: ...mple Gross xxxxx0 18lb Tare xxxxxx0 18lb Net xxxxxxx0 18lb Format LF Gross reading minus decimal point unit CR EXT LF Tare reading decimal point unit CR EXT LF Net reading minus decimal point unit CR...

Страница 12: ...olution 00 500 08 2400 15 7000 01 600 09 2500 16 7500 02 750 10 3000 17 8000 03 800 11 3500 18 10 000 04 1000 12 4000 19 12 000 05 1200 13 5000 20 15 000 06 1500 14 6000 21 31 N A 07 2000 P8 0 1 2 See...

Страница 13: ...0 kg lb 5 Single point calibration enter the same weight in again and move to number 7 For 2 point calibration enter in the second calibration weight between 25 100 full capacity Tare 6 7 Tare 8 9 Tar...

Страница 14: ...and LB P12 0 7 7 Power On zero range full scale 0 1 1 2 2 5 3 10 4 20 5 50 6 100 7 no limitation P13 00 15 3 Zero button range Full scale 00 1 06 20 12 5 01 2 07 no limit 13 10 02 3 08 1 14 20 03 4 09...

Страница 15: ...ill be turned off in two minutes automatically AC Adapter 10 5 12VDC 600mA with central positive 5 7 VDC 9 VDC Error Messages Error Message Definition Required Solution Troubleshooting 0 Weight above...

Страница 16: ...ications Le pr sent appareil num rique n met pas de bruits radio lectriques d passant les limites applicables aux appareils num riques de la Classe A prescrites dans le R glement sur le brouillage rad...