Salter Brecknell S-100 Скачать руководство пользователя страница 3

Contents 
 
WARNINGS ............................................................................................................................................................ 2

 

Product Identification Table ................................................................................................................................. 3

 

ASSEMBLY ............................................................................................................................................................ 4

 

Product Contents................................................................................................................................................ 4

 

Setting the Indicator Up for Use.......................................................................................................................... 4

 

Wire the cable attached to the base as shown (if necessary) ............................................................................. 4

 

Indicator and Platform Assembly ........................................................................................................................ 5

 

Display and Keypad............................................................................................................................................ 6

 

Manual symbols.................................................................................................................................................. 6

 

Scale Operation..................................................................................................................................................... 7

 

Turning On and Zeroing the Scale...................................................................................................................... 7

 

Selecting Unit of Measure................................................................................................................................... 7

 

Using the Tare .................................................................................................................................................... 7

 

Hold function with automatic zero on next weigh. ............................................................................................... 8

 

Hold function with manual release. ..................................................................................................................... 8

 

Removing Hold ................................................................................................................................................... 8

 

Print Function ..................................................................................................................................................... 8

 

USER CONFIGURATION SETTINGS .................................................................................................................... 9

 

Setup Controls.................................................................................................................................................... 9

 

Entering setup .................................................................................................................................................... 9

 

User Configuration Settings

.................................................................................................................................. 10

 

RS-232 data commands for SBI protocol .............................................................................................................. 11

 

Other RS-232 Output Strings............................................................................................................................ 12

 

RS232 serial interface wiring ............................................................................................................................ 12

 

Scale calibration ................................................................................................................................................. 13

 

Calibration Configuration Settings –.................................................................................................................. 13

 

Factory Calibration Settings shown in bold ....................................................................................................... 13

 

Calibration Menu

............................................................................................................................................. 14

 

Service Configuration Settings.......................................................................................................................... 15

 

Technical Specifications .................................................................................................................................... 16

 

 Error Messages .................................................................................................................................................. 16

 

Declarations of Compliance ............................................................................................................................... 17

 

Contact Information & Technical Support ......................................................................................................... 17

 

 

 

Product Identification Table 

Part Number 

Capacity 

Region 

Power Supply (s) 

816965001620 
 

75 kg x 0.01kg / 150lb x 0.02lb 

North America 

US Version, UL 

816965001637 
 

150 kg x 0.02kg / 300lb x 0.05lb 

North America 

US Version, UL 

816965001644 
 

300 kg x 0.05kg / 600lb x 0.1lb. 

North America 

US Version, UL 

816965002160 
 

75 kg x 0.01kg / 150lb x 0.02lb. 

UK/EU 

3 pin UK & 3 pin EU 
,CE approved 

816965002177 
 

150 kg x 0.02kg / 300lb x 0.05lb. 

UK/EU 

3 pin UK & 3 pin EU 
,CE approved 

816965002184 
 

300 kg x 0.05kg / 600lb x 0.1lb. 

UK/EU 

3 pin UK & 3 pin EU 
,CE approved 

816965002719 
 

75 kg x 0.01kg / 150lb x 0.02lb. 

AUS/SA 

3-pin Australia C-Tick 
approved, 3 pin South 
Africa 

816965002726 
 

150 kg x 0.02kg / 300lb x 0.05lb. 

AUS/SA 

3-pin Australia C-Tick 
approved, 3 pin South 
Africa 

816965002733 
 

300 kg x 0.05kg / 600lb x 0.1lb. 

AUS/SA 

3-pin Australia C-Tick 
approved, 3 pin South 
Africa 

Содержание S-100

Страница 1: ...Model S 100 Floor Scale Operation Manual Manual xxxxxx Issue xx...

Страница 2: ...DOUBT SEEK ADVICE FROM A QUALIFIED ELECTRICIAN Routine maintenance To avoid the possibility of electric shock or damage to the machine always switch off the machine and isolate from the power supply...

Страница 3: ...nu 14 Service Configuration Settings 15 Technical Specifications 16 Error Messages 16 Declarations of Compliance 17 Contact Information Technical Support 17 Product Identification Table Part Number Ca...

Страница 4: ...oadcell socket Power Adapter Socket Power Supply Connecting the Indicator to the Platform 6VDC 500mA 230V 50Hz Wire the cable attached to the base as shown if necessary 4 2 3 1 1 RED 2 RED 3 RED 4 RED...

Страница 5: ...Indicator and Platform Assembly Rem ove packagin g pa ds x2 x2 1 2 3 x4 4 5...

Страница 6: ...0 Weight is zero On Off Zero On Off Zero kg lb Unit of measure Flashing LED means that the weight reading is not stable Units kg lb Unit of measurement NET Tare is activated Hold Print Hold Print CH B...

Страница 7: ...tion Turning On and Zeroing the Scale On Off Zero ZERO 0 Turning off the scale On Off Zero Selecting Unit of Measure Units kg lb Using the Tare 1 2 3 NET 4 NET Removing the Tare On Off Zero 0 ZERO kg...

Страница 8: ...old function with manual release This function needs to be setup in Parameter P3 1 shown on page 10 1 Hold Print Hold 2 3 Removing Hold Hold Print Hold Print Function For communications to a printer o...

Страница 9: ...ecting parameter Tare Changing data within the parameter Units Saving data Tare Exiting setup On Off Zero ZERO 0 Gross 45 00kg Tare 1 35kg Net 43 65kg Hold Print kg Moves flashing digit Units Change f...

Страница 10: ...ctable hold window from 3 to 50 divisions Will hold display reading once stable within a selectable weight range to release the hold button must be represses P3 0 P3 1 P3 2 P3 3 to 50 P4 x RS232 Seria...

Страница 11: ...tare LF H1H2H3 CR ETX U CR Changes the units LF u1u2 CR LF H1H2H3 CR ETX L CR Activates the hold function LF H1H2H3 CR ETX X CR Switches off the scale Indicator switches off Unrecognised command LF CR...

Страница 12: ...minus decimal point unit CR EXT LF Tare reading decimal point unit CR EXT LF Net reading minus decimal point unit CR EXT RS232 serial interface wiring DE 9 Female Scale DE 9 Male Host Pin Name Direct...

Страница 13: ...bration weight 0 KG 1 LB Factory Calibration Settings shown in bold Primary Capacity Displayed Resolution Units Selectable Capacity P7 P8 P9 P10 150 lb x 0 02 lb 7500 75 kg x 0 01kg 16 1 2 1 150 x 0 0...

Страница 14: ...g lb 5 Single point calibration enter the same weight in again and move to number 7 For 2 point calibration enter in the second calibration weight between 25 100 full capacity Tare 6 7 Tare 8 9 Tare Z...

Страница 15: ...5 50 6 100 7 no limitation P13 00 15 3 Zero button range Full scale 00 1 06 20 12 5 01 2 07 no limit 13 10 02 3 08 1 14 20 03 4 09 2 25 no limit 04 5 10 3 05 10 11 4 P14 0 1 2 0 Signal within power on...

Страница 16: ...ill be turned off in two minutes automatically AC Adapter 10 5 12VDC 600mA with central positive 5 7 VDC 9 VDC Error Messages Error Message Definition Required Solution Troubleshooting 0 Weight above...