Service Configuration Settings 

The scale is configured from the factory to match the specified settings for each unit, as defined by the product 
specifications and sales brochure.  Modification of the setting can be accomplished by altering user configuration 
settings P11-P19. 

Caution:

 Configuration of the settings of your scale should be accomplished by a trained 

service technician to ensure proper operation and accuracy.  Configuration is not covered under warranty.  

 
Setup Controls 

 
 
 
 
 

 
 
 
 

 

 
 
Config 

Menu 

Avail. 

Settings 

Default Definition 

Detailed 

Setting 

P11 0,1,2 

Units key 
configuration 

0 = KG only ; 1 = LB only ; 2 = units key active KG 
and LB   

P12 

0-7 

Power On zero 
range (full 
scale) 

0 = +/- 1% ; 1 = +/- 2% ;  2 = +/- 5% ; 3 = +/- 10% ; 4 = 
+/- 20% ; 5 = +/- 50% ; 6 = +/- 100% ; 7 = no limitation 

P13 

00 - 15 

Zero button 
range (Full 
scale) 

(00) = +/- 1%      (06) = +/- 20%        (12) = + 5% 
(01 )= +/- 2%      (07) = +/-no limit     (13) = + 10% 
(02 )= +/- 3%      (08 )= + 1%             (14) = + 20% 
(03 )= +/- 4%      (09) = + 2%             (25) = + no limit 
(04) =+/- 5%       (10 )=  + 3%        
(05 )= +/- 10%    (11) =  + 4%        
 

P14 

0, 1, 2 

Signal within 
power on zero 
point range 

0 = current weight ; 1 = calibration zero ; 2 = power off 
zero point 

P15 

0, 1, 2 

Signal not 
within power on 
zero point 

0 = current weight ; 1 = calibration zero ; 2 = power off 
zero point ; 3 = continuously display “0

- - - - -

“ 

P16 0-8 

 

Zero tracking 

0 = 0d AZT off ; 1 = +/- 0.25d, 2 = +/- 0.5d ; 3 = +/- 1d; 
4= +/- 1.5d ;5= +/- 2d ;6 = +/- 3d; 7= +/- 4d; 8 = +/- 5d  

P17 

0-3 

Data Filter  

0 = very weak; 1 = weak; 2 = standard; 3 = strong  

P18 

0 - 9 

Weight stability 

0 = +/- 0.5d ; 1= +/- 1d;  2= +/- 1.5d ; 3= +/- 2d; 4= +/- 
3d ;5= +/- 4d ;6 = +/- 5d; 7= +/- 6d; 8 = +/- 7d; 9 = +/-
8d 

P19 0-9 

1  Overload 

range 

Full scale 

0 = 0% ; 1 = +9d ;  2 = 101% ; 3 = 102% ; 4 = 405% ; 
5 = 110% ; 6 = 120% ; 7 = 150%; 8 =  200%; 9 = no 
limitation 

Hold

Print

 

kg

 

     

Moves flashing digit

 

Units

 

 

  

 

 

Change flashed digits

Tare

       

       

kg

 

 
Saves data and move down 
to next Parameter setting 
 .

 

On/Off

Zero

 

 
 
 
 

Exits setup mode

Содержание S-100

Страница 1: ...Model S 100 Floor Scale Operation Manual Manual xxxxxx Issue xx...

Страница 2: ...DOUBT SEEK ADVICE FROM A QUALIFIED ELECTRICIAN Routine maintenance To avoid the possibility of electric shock or damage to the machine always switch off the machine and isolate from the power supply...

Страница 3: ...nu 14 Service Configuration Settings 15 Technical Specifications 16 Error Messages 16 Declarations of Compliance 17 Contact Information Technical Support 17 Product Identification Table Part Number Ca...

Страница 4: ...oadcell socket Power Adapter Socket Power Supply Connecting the Indicator to the Platform 6VDC 500mA 230V 50Hz Wire the cable attached to the base as shown if necessary 4 2 3 1 1 RED 2 RED 3 RED 4 RED...

Страница 5: ...Indicator and Platform Assembly Rem ove packagin g pa ds x2 x2 1 2 3 x4 4 5...

Страница 6: ...0 Weight is zero On Off Zero On Off Zero kg lb Unit of measure Flashing LED means that the weight reading is not stable Units kg lb Unit of measurement NET Tare is activated Hold Print Hold Print CH B...

Страница 7: ...tion Turning On and Zeroing the Scale On Off Zero ZERO 0 Turning off the scale On Off Zero Selecting Unit of Measure Units kg lb Using the Tare 1 2 3 NET 4 NET Removing the Tare On Off Zero 0 ZERO kg...

Страница 8: ...old function with manual release This function needs to be setup in Parameter P3 1 shown on page 10 1 Hold Print Hold 2 3 Removing Hold Hold Print Hold Print Function For communications to a printer o...

Страница 9: ...ecting parameter Tare Changing data within the parameter Units Saving data Tare Exiting setup On Off Zero ZERO 0 Gross 45 00kg Tare 1 35kg Net 43 65kg Hold Print kg Moves flashing digit Units Change f...

Страница 10: ...ctable hold window from 3 to 50 divisions Will hold display reading once stable within a selectable weight range to release the hold button must be represses P3 0 P3 1 P3 2 P3 3 to 50 P4 x RS232 Seria...

Страница 11: ...tare LF H1H2H3 CR ETX U CR Changes the units LF u1u2 CR LF H1H2H3 CR ETX L CR Activates the hold function LF H1H2H3 CR ETX X CR Switches off the scale Indicator switches off Unrecognised command LF CR...

Страница 12: ...minus decimal point unit CR EXT LF Tare reading decimal point unit CR EXT LF Net reading minus decimal point unit CR EXT RS232 serial interface wiring DE 9 Female Scale DE 9 Male Host Pin Name Direct...

Страница 13: ...bration weight 0 KG 1 LB Factory Calibration Settings shown in bold Primary Capacity Displayed Resolution Units Selectable Capacity P7 P8 P9 P10 150 lb x 0 02 lb 7500 75 kg x 0 01kg 16 1 2 1 150 x 0 0...

Страница 14: ...g lb 5 Single point calibration enter the same weight in again and move to number 7 For 2 point calibration enter in the second calibration weight between 25 100 full capacity Tare 6 7 Tare 8 9 Tare Z...

Страница 15: ...5 50 6 100 7 no limitation P13 00 15 3 Zero button range Full scale 00 1 06 20 12 5 01 2 07 no limit 13 10 02 3 08 1 14 20 03 4 09 2 25 no limit 04 5 10 3 05 10 11 4 P14 0 1 2 0 Signal within power on...

Страница 16: ...ill be turned off in two minutes automatically AC Adapter 10 5 12VDC 600mA with central positive 5 7 VDC 9 VDC Error Messages Error Message Definition Required Solution Troubleshooting 0 Weight above...

Страница 17: ...ications Le pr sent appareil num rique n met pas de bruits radio lectriques d passant les limites applicables aux appareils num riques de la Classe A prescrites dans le R glement sur le brouillage rad...

Отзывы: