WARNINGS 

Safe installation 
Safety

 

 

 

 

THE EQUIPMENT CONTAINS NO USER SERVICEABLE COMPONENTS. 

Installation and maintenance of the equipment must only be carried out by trained and authorised 
personnel. 

 

Electrical installation 

The mains lead must be connected to a supply outlet with a protective earth contact. The electrical supply 
at the socket outlet must provide over current protection of an appropriate rating. 
For your protection all mains (110V or 230V) equipment used out of doors or in wet or damp conditions 
should be supplied from a correctly fused source and protected by an approved ground fault protection 
device (RCD, GFCI etc.) 
IF IN DOUBT SEEK ADVICE FROM A QUALIFIED ELECTRICIAN. 

 

Routine maintenance 

To avoid the possibility of electric shock or damage to the machine, always switch off the machine and 
isolate from the power supply before carrying out any routine maintenance. 
To avoid the risk of the machine falling, where applicable, ensure that it is placed securely on a flat and 
level surface. 

 
 
 
Safe use 
Caution – Cleaning the indicator/weigh head 

Harsh abrasives, solvents, scouring cleaners and alkaline cleaning solutions, such as washing soda, 
should not be used especially on the display windows. Under no circumstances should you attempt to 
wipe the inside of the machine. 
The outside of standard products may be wiped down with a clean cloth, moistened with water containing 
a small amount of washing up liquid. 
The outside of products waterproofed to IP65, IP66 and IP67 may be washed down with water containing 
a small amount of proprietary detergent. 

 

Training 

Do not attempt to carry out any procedure on a machine unless you have received the appropriate 
training or read the Instruction Manual. 

 
 

EMC compliance 

 

The following may be applicable to your machine. 

 WARNING: 

This is a class A product. In a domestic environment this product may cause radio interference in which 
case the user may be required to take adequate measures. 

 

 

 
 
 
 
 
 
 

 

 

Содержание S-100

Страница 1: ...Model S 100 Floor Scale Operation Manual Manual xxxxxx Issue xx...

Страница 2: ...DOUBT SEEK ADVICE FROM A QUALIFIED ELECTRICIAN Routine maintenance To avoid the possibility of electric shock or damage to the machine always switch off the machine and isolate from the power supply...

Страница 3: ...nu 14 Service Configuration Settings 15 Technical Specifications 16 Error Messages 16 Declarations of Compliance 17 Contact Information Technical Support 17 Product Identification Table Part Number Ca...

Страница 4: ...oadcell socket Power Adapter Socket Power Supply Connecting the Indicator to the Platform 6VDC 500mA 230V 50Hz Wire the cable attached to the base as shown if necessary 4 2 3 1 1 RED 2 RED 3 RED 4 RED...

Страница 5: ...Indicator and Platform Assembly Rem ove packagin g pa ds x2 x2 1 2 3 x4 4 5...

Страница 6: ...0 Weight is zero On Off Zero On Off Zero kg lb Unit of measure Flashing LED means that the weight reading is not stable Units kg lb Unit of measurement NET Tare is activated Hold Print Hold Print CH B...

Страница 7: ...tion Turning On and Zeroing the Scale On Off Zero ZERO 0 Turning off the scale On Off Zero Selecting Unit of Measure Units kg lb Using the Tare 1 2 3 NET 4 NET Removing the Tare On Off Zero 0 ZERO kg...

Страница 8: ...old function with manual release This function needs to be setup in Parameter P3 1 shown on page 10 1 Hold Print Hold 2 3 Removing Hold Hold Print Hold Print Function For communications to a printer o...

Страница 9: ...ecting parameter Tare Changing data within the parameter Units Saving data Tare Exiting setup On Off Zero ZERO 0 Gross 45 00kg Tare 1 35kg Net 43 65kg Hold Print kg Moves flashing digit Units Change f...

Страница 10: ...ctable hold window from 3 to 50 divisions Will hold display reading once stable within a selectable weight range to release the hold button must be represses P3 0 P3 1 P3 2 P3 3 to 50 P4 x RS232 Seria...

Страница 11: ...tare LF H1H2H3 CR ETX U CR Changes the units LF u1u2 CR LF H1H2H3 CR ETX L CR Activates the hold function LF H1H2H3 CR ETX X CR Switches off the scale Indicator switches off Unrecognised command LF CR...

Страница 12: ...minus decimal point unit CR EXT LF Tare reading decimal point unit CR EXT LF Net reading minus decimal point unit CR EXT RS232 serial interface wiring DE 9 Female Scale DE 9 Male Host Pin Name Direct...

Страница 13: ...bration weight 0 KG 1 LB Factory Calibration Settings shown in bold Primary Capacity Displayed Resolution Units Selectable Capacity P7 P8 P9 P10 150 lb x 0 02 lb 7500 75 kg x 0 01kg 16 1 2 1 150 x 0 0...

Страница 14: ...g lb 5 Single point calibration enter the same weight in again and move to number 7 For 2 point calibration enter in the second calibration weight between 25 100 full capacity Tare 6 7 Tare 8 9 Tare Z...

Страница 15: ...5 50 6 100 7 no limitation P13 00 15 3 Zero button range Full scale 00 1 06 20 12 5 01 2 07 no limit 13 10 02 3 08 1 14 20 03 4 09 2 25 no limit 04 5 10 3 05 10 11 4 P14 0 1 2 0 Signal within power on...

Страница 16: ...ill be turned off in two minutes automatically AC Adapter 10 5 12VDC 600mA with central positive 5 7 VDC 9 VDC Error Messages Error Message Definition Required Solution Troubleshooting 0 Weight above...

Страница 17: ...ications Le pr sent appareil num rique n met pas de bruits radio lectriques d passant les limites applicables aux appareils num riques de la Classe A prescrites dans le R glement sur le brouillage rad...

Отзывы: