5.4) P4.x: RS232 mode setting
x=0: No RS232 function. It will not transmit or receive any data
although the scale is with RS232 hardware. RS232 function can be only
activated when scale is in normal weighing mode.
x=1:Press PRINT/HOLD key, the scale will output the current stable
displayed weight reading and weight unit, and not receive any data
from other equipment. The output format is as below:
<LF>< reading, minus, decimal point, weight unit><CR><EXT>
x=2: Press PRINT/HOLD key, the scale will output the data of stable
current gross, tare, net weight reading and weight unit. The format
is
as
follows:
<LF><Gross: reading, minus, decimal point, unit><CR><EXT>
<LF> <Tare: reading, decimal point, unit><CR><EXT>
<LF> <Net: reading, minus, decimal point, unit><CR><EXT>
The number of position used: weight reading ---7;
Minus
---1;
Decimal
point
---1;
Weight unit ---2 or 4;
x=3: Continuously output of the current displayed reading and unit, and it
does not receive any data. The output format is same as x=1.
x=4: Continuously output of the current gross weight, tare weight and net
weight reading data including unit, and not accept any data. The
output format is same as x=2.
X=5: When the scale is stable, it will output the current displayed weight
reading automatically one time including unit, and not accept data.
The output format is same as x=1.
X=6: When the scale is stable, it will output the current gross weight, tare
weight and net weight data including unit automatically one time, and not
accept data. The output format is same as x=2.
X=7: Bio-RS232 data output compatible to the NCI-SP1 format.
5.5) P5.x: Baud rate of RS232 communication
x=0:
1200bps
x=1:
2400bps
x=2:
4800bps
12
x=3:
9600bps
x=4:
19200bps
5.6) P6.x: RS232 communication data format
x=0: 8N0 8 digits, no odd or even , 1 start bit, 1stop bit
x=1: 7O1 7 digits, 1 odd, 1 start bit, 1stop bit
x=2: 7E1 7 digits, 1 even, 1 start bit, 1stop bit
5.7) P7.xy: calibration resolution
Table2:
xy
calibration resolution
xy
calibration resolution
00 500 16 7500
01 600 17 8000
02 750 18
10000
03 800 19
12000
04 1000 20 15000
05 1200 21 20000
06 1500 22 25000
07 2000 23 30000
08 2400 24 35000
09 2500 25 40000
10 3000 26 50000
11 3500 27 60000
12 4000 28 70000
13 5000 29 75000
14 6000 30 80000
15 7000 31
100000
5.8) P8.x: calibration division
x=0:
1
x=1:
2
x=2:
5
5.9) P9.x: decimal point in calibration mode
13