![Salter Brecknell LPS-150 Скачать руководство пользователя страница 13](http://html1.mh-extra.com/html/salter-brecknell/lps-150/lps-150_operation-manual_802870013.webp)
④
<LF><p>w1w2w3w4w5w6<dp>w7u1u2<CR><LF>H1H2H3<CR><ETX>
---Scale is stable, and the current weight unit is kg or lb. With or without decimal
point and the position is as per the P9 setting and current unit.
⑤
<LF><p>w1w2w3w4w5lb<sp>w6w7<o><z><CR>H1H2H3<CR><ETX>
Or <LF><p>w1w2w3w4lb<sp> w5w6<dp>w7oz<CR>H1H2H3<CR><ETX>
----The current unit is lb: oz.
(2) Command:
S<CR>
(53h 0dh)
Response: <LF> H1H2H3<CR><ETX>
(3) Command:
Z<CR>
(5ah 0dh)
Response: Zero function is activated and it returns to current scale status. just
like pressing ZERO/ON/OFF button:
<LF> H1H2H3<CR><ETX>
If ZERO function cannot be activated, it will return to current scale status.
(4) Command:
T<CR>
(54h 0dh)
Response: TARE function is activated, and then returns scale status. just like
pressing TARE button:
<LF> H1H2H3<CR><ETX>
If TARE function cannot be activated, it will return to current scale status.
(5) Command:
U<CR>
(55h 0dh)
Response: Changes units of measure and return scale status with new units,
just like pressing UNIT button. The new measure unit should be allowed to
use as per P11 setting.
<LF>u1u2<CR><LF> H1H2H3<CR><ETX>
If the weight unit is lb:oz, U1U2= lb oz
(6) Command:
L<CR>
(4ch 0dh)
Response: If Hold function can be activated, it will enable/disable hold (lock)
function, like the
HOLD
key is pressed, and returns scale status.
<LF> H1H2H3 <CR><ETX>
(7) Command:
X<CR>
(58h 0dh)
Response: power off the scale, just like press down the
ON/OFF
key to turn
off the scale.
20
(8) Command:
all others
Response: Unrecognized command
<LF>? <CR><ETX>
2.5) Output status bit meaning:
Table5: The status bits definition:
Bit
Byte 1 (H
1
)
Byte 2 (H
2
)
Byte 3 (H
3
)
0=stable
0= not under capacity
0
1= not stable
1= under capacity
0= not at zero point 0= not over capacity
1
1= at zero point
1= over capacity
01=normal work mode
10= hold work mode
00=not define
11= not define
0= gross weight
2
always 0
always 0
1= net weight
0= eeprom OK
3
1= eeprom error
always 0
always 0
4
always 1
always 1
always 1
5
always 1
always 1
always 1
6
always 0
always 1
always 0
7
parity Parity parity
Ⅶ
.
Relationship of capacity and the setting of P7, P8 and P9:
Table6: (Capacity unit is kg or lb)
Division set by P8 and P9(P8=0)
Resoluti
on set by
P7
0.0001
0.001
0.01
0.1
1
10
500
0.0500
0.500
5.00
50.0
500
5000
600
0.0600
0.600
6.00
60.0
600
6000
750
0.0750
0.750
7.50
75.0
750
7500
800
0.0800
0.800
8.00
80.0
800
8000
1000
0.1000
1.000
10.00
100.0
1000
10000
21