62
SALICRU
MESSAGE ON-SCREEN CLASSIFICA-
TION
DESCRIPTION
UPS Stop by Temp High.
UPS STOP
UPS stop heat sink overtemperature.
UPS Stop No Rec Input V
No rectifier input voltage (neither AC nor DC).
UPS Stop Rec Dst IGBT R
IGBT rectifier maximum desaturation phase R.
UPS Stop Rec Dst IGBT S
IGBT rectifier maximum desaturation phase S.
UPS Stop Rec Dst IGBT T
IGBT rectifier maximum desaturation phase T.
UPS Stop by DC Bus high
UPS Stop high DC bus.
UPS Stop End Backup Time
UPS Stop end of autonomy.
UPS Stop Rec Ph Rotation
UPS Stop rectifier input phase rotation.
UPS Stop Rec C.Sharing
UPS incorrect rectifier current sharing among power blocks.
UPS Stop Ext Shut-Down
UPS Stop due to external shutdown signal.
UPS Stop Parall. Com Flt
UPS Stop parallel communication fault.
UPS Stop Rectifier OVL
UPS Stop due to rectifier overload.
UPS Stop Main SPS Flt
UPS Stop Main Supply Fault.
UPS Block C.Sharing
UPS blocked due to exceed stop retries incorrect rectifier current sharing among
power blocks.
Rec Stop Desat IGBT R
RECTIFIER STOP
Rectifier stop IGBT desaturation phase R.
Rec Stop Desat IGBT S
Rectifier stop IGBT desaturation phase S.
Rec Stop Desat IGBT T
Rectifier stop IGBT desaturation phase T.
Rec Stop AC fail Start
Rectifier stop AC input fault at start-up.
Rec Stop Bat fail Start
Rectifier stop DC battery fault at start-up.
Rec Stop S.Strt T.Out
Rectifier stop due to soft start waiting time.
Rec Stop S.Strt in-rush
Rectifier stop due to input overcurrent during soft start.
Rec Stop by Sync fail
Rectifier stop due to input synchronisation fault.
Chg Stop by Desaturation
CHARGER
STOP
Charger stop due to desaturations.
Chg Stop by Time-out
Charger stop due to waiting time.
Chg Stop No Battery
Charger stop due to lack of detection of batteries.
Inv Stop by Overload
INVERTER
STOP
Inverter stop due to overload.
Inv Stop Desat IGBT R
Maximum inverter IGBT desaturations phase R.
Inv Stop Desat IGBT S
Maximum inverter IGBT desaturations phase S.
Inv Stop Desat IGBT T
Maximum inverter IGBT desaturations phase T.
Inv Stop Maintenance Byp
Inverter stop maintenance bypass.
Inv Stop by Byp Rotation
Inverter stop due to bypass input phase rotation.
Inv Stop C.Sharing
Inverter stop due to incorrect inverter or output current sharing among power blocks.
Inv Stop Out OFF Short
Inverter stop and bypass deactivated due to a short circuit at the output.
Inv Stop by V ramp error
Inverter stop due to voltage ramp fault.
Inv Stop Byp Tx Par Sys
Inverter stop and switch to bypass via the parallel system.
Inv Stop by Time-Out
Inverter stop, command waiting time exceeded.
Inv Stop Volt R margins
Inverter stop phase R due to voltage ranges.
Inv Stop Volt S margins
Inverter stop phase S due to voltage ranges.
Inv Stop Volt T margins
Inverter stop phase T due to voltage ranges.
Inv Stop DC Bus voltage
Inverter stop due to DC link out of margins.