background image

6

3.  Quality assurance and 

standards.

3.1.  Statement by the management.

Our goal is customer satisfaction, therefore this Management 
has decided to establish a Quality and Environment Policy, 
through the implementation of a Quality and Environmental Man-
agement System that will enable us to comply with the require-
ments demanded in the 

ISO 9001

 and 

ISO 14001

 and also by 

our Customers and Stakeholders.
Likewise, the management of the company is committed to the 
development and improvement of the Quality and Environmental 
Management System, through:

• 

Communication to the entire company of the importance of 

satisfying both the customer's requirements as well as legal 

and regulatory requirements.

• 

The dissemination of the Quality and Environment Policy and 

the setting of the Quality and Environment objectives.

• 

Conducting reviews by the Management.

• 

Providing the necessary resources.

3.2.  Standards.

The 

DC Power-L 12-pulse DC-75-LP12 110V EE671774-1

 is 

designed, manufactured and sold in accordance with Quality 
Management Systems standard 

EN ISO 9001

 and is certified 

by the company SGS. The 

 marking indicates conformity with 

EC Directives through the application of the following standards:

•  IEC/EN 61204-7.

 - Low-voltage power supplies, d.c. output.

Part 7: Safety requirements.

 

ˆ

Reference standard:

IEC/EN 60950-1.

 - Information technology equipment. 

Safety. Part 1: General requirements.

•  IEC/EN 61204-3.

 - Low-voltage power supply devices, d.c. 

output. 
Part 3: Electromagnetic compatibility. 

The manufacturer is not liable in the event of modification 
or intervention on the device by the user.

This is a Class A device. In residential, commercial or light 
industry environments, it may cause radio interference. 

This device is not intended to be installed in a residential, com-
mercial or light industry environment. In the event of connection 
to the public electricity supply, the user may be required to take 
all appropriate measures to reduce interference.

The product’s CE declaration of conformity is available to 
the customer upon express request to our head office.

3.3.  Environment.

This product has been designed to respect the environment and 
manufactured in accordance with 

ISO 14001

.

Recycling of the device at the end of its useful life:

Our company undertakes to use the services of authorised and 
regulatory companies to treat the set of products recovered at 
the end of their useful life (contact your distributor).

Packaging:

To recycle the packaging, please comply with any legal require-
ments in force.

Batteries

:

Batteries pose a serious danger to health and the environment. 
The disposal of them shall be carried out in accordance with the 
laws in force.

USER MANUAL

Содержание DC POWER-L Series

Страница 1: ...P DOWN LIGHT DIMMERS ILUEST POWER SOURCES STATIC INVERTERS PHOTOVOLTAIC INVERTERS LINE VOLTAGE STABILISERS MANUAL EE671774 1 DC POWER SUPPLY DEVICE THYRISTOR CONTROLLED CHARGER RECTIFIER 12 PULSE DC P...

Страница 2: ...2 USER MANUAL...

Страница 3: ...eception and unpacking 6 2 Packing list and contents 6 3 Storage 7 Installation 7 1 Look after your safety 7 2 Considerations to take into account 7 3 Earth connection terminal or strip 7 4 Connection...

Страница 4: ...fied per sonnel Although no effort has been spared to ensure that the information in this user manual is complete and accurate we accept no liability for any errors or omissions that may exist The ima...

Страница 5: ...e device is installed and operating it is recom mended to keep the documentation pendrive in a safe and easy to access location for future reference If a system differs from that shown in the figures...

Страница 6: ...plies d c output Part 7 Safety requirements Reference standard IEC EN 60950 1 Information technology equipment Safety Part 1 General requirements IEC EN 61204 3 Low voltage power supply devices d c ou...

Страница 7: ...o earth the protection will always be single pole so as not to disconnect the pole from earth The entry of connection cables is through the base of the cab inet Optionally and on request cable entry c...

Страница 8: ...ker Q2 Battery circuit breaker Q3 Input terminals R S T Battery terminals Output terminals Cable input gland Earth Terminal Alarm interface X32 see Table 2 Interface Aux Contacts X34 refer to Table 3...

Страница 9: ...ck format with a 623 x 803 mm base The dimensions of the rectifier and battery cabinets are the same and the only external difference is the control panel on the device The device can operate with PbC...

Страница 10: ...ltage 110 Rated output voltage with positive to earth 110 Rated output voltage with negative to earth L Device series standard version only single phase devices with 5 ripple and no Schuko socket LP D...

Страница 11: ...n the event of input mains failure or output overloads 5 2 2 AC input For greater versatility the system can be either single phase or three phase Regardless of the topology of the mains protection el...

Страница 12: ...erride con trol the control is transferred to another current PID when one of the current limits is exceeded batteries or rectifier A selective control enables automatic switching between the two curr...

Страница 13: ...event of input wave voltage and frequency variations The output current of each charger is equal to the current de manded by 100 of the loads plus the maximum charging cur rent of the battery accordi...

Страница 14: ...tions Each automatic deactivation automatically recalculates the next periodic trip Table 5 Activation and deactivation of fast charging Exceptional charging Automatic Manual Periodic Activation No Vi...

Страница 15: ...if re quested in the order cardboard box expanded polystyrene EPS corners polyethylene cover and polyester strapping All of these materials are recyclable so any disposal must be carried out in accord...

Страница 16: ...6 3 Storage The device should be stored in a dry ventilated room and pro tected from rain dust and water or chemical splashes It is advisable to keep devices and batteries in their original pack agin...

Страница 17: ...up operations The surface on which the system is to be installed must be properly prepared to support its weight and level to prevent the metal structure from having to withstand unnecessary and harmf...

Страница 18: ...e accumulator bank with the resultant risk It should never be forgotten that the DC Power L with batteries is a generator of electrical power regardless of whether the batteries are installed in the s...

Страница 19: ...phase or three phase AC power supply network All of the protections or disconnectors of the system must be in the Off position and in particular that of the the batteries of the device Q3 and its cou...

Страница 20: ...bles red for positive and black for negative and the polarity indicated on the labelling of the device Connect the load or loads to the earth terminal or strip It is recommended to distribute the outp...

Страница 21: ...tically or manually Exceptional charging Exceptional charging is forced manually at the will of the operator via the control panel 8 1 Startup procedure Set battery circuit breaker Q3 to On In systems...

Страница 22: ...main screen of the system which appears when the device starts up It is also the screen that appears when is pressed to exit any of the other menus or sub menus of the control panel with LCD The first...

Страница 23: ...Screen 2 1 This is the gateway to the device s switching menu Screen 2 2 Manual and forced activation of fast charging 9 3 4 User Parameters menu To access this menu from the home screen press the fo...

Страница 24: ...MP C MIN T COMP C QUICK CHARGING MAX T min PERIODIC CHARGING INTERVAL Days BATT FLOAT CHARGE TIME h LOW BATTERY VOLTAGE x x x x V OUTPUT VOLTAGE LOW V INSULATION ALARM Kohm INSULATION MEASUREMENT S N...

Страница 25: ...auxiliary contact closed Urgent 5 Current leakage alarm Isol res approx 5 K Isol res approx 5 K Not urgent 5 Electrolyte level low alarm Electrolyte low level Electrolyte normal level Not urgent 1 Ch...

Страница 26: ...C input failure Phase rotation error RELE 2 EMERGENCY fault Output overvoltage Output undervoltage High battery voltage Low battery voltage Battery fuse blown Rectifier fuse blown Input switch open Ou...

Страница 27: ...lower than the nominal setting of the device Screen 6 6 Use this screen to set the rectifier s overload alarm threshold Screen 6 7 Use this screen to activate or deactivate the rectifier output isola...

Страница 28: ...itors The service life of the capacitors in the DC bus and those used for input and output filtering depends on use and environmental conditions Preventative replacement by authorised technical person...

Страница 29: ...Batteries in system cabinet Fuses Batteries in external cabinet Fuses General output switch Disconnector Soft start Yes COMMUNICATION AND ALARMS Slot Yes one pre connected as standard SNMP Remote mai...

Страница 30: ...y depending on their temperature they can function as insulators or conductors It is a one way device because it only transmits the current in a single direction It is generally used to control electr...

Страница 31: ...31 SALICRU...

Страница 32: ...R EGYPT PHILIPPINES NETHERLANDS INDONESIA IRELAND JORDAN KUWAIT MALAYSIA PERU POLAND CZECH REPUBLIC RUSSIA SWEDEN SWITZERLAND THAILAND TUNISIA UAE URUGUAY VENEZUELA VIETNAM REST OF THE WORLD Product r...

Отзывы: