background image

| EN

VSA 3.0_VSA EKO v2019.04

SYMBOLS AND MARKING

Product name

Nominal voltage frequency

Max.current

Max.power consumption

Protection class

/

000 0 VAC

00.00 A

0.00 kW

IP 00

/ 0

/Hz

Made in Šiauliai, Lithuania

SKU000000

LN: LN000000      2019.01.01

1

4

5

2

6

3

Figure 1.1 - Technical label

1 - Logo; 2 - Product code (SKU); 3 - Product name; 4 - Technical data; 5 - Production place; 6 - Lot number and production date.

Techninis

lipdukas

XXX GAMINIO  PA VADINIMA S

Nominal voltage frequency

Max.current

Max.power consumption

Protection class

Weight

/

xxx/xx VAC/Hz

x.xx A

x.xx kW

IP xx

xx kg

Made in Šiauliai, Lithuani a

FAN000040

BN:xxxxxx

2019/01/01

Techninis

lipdukas

Product name

Nominal voltage frequency

Max.current

Max.power consumption

Protection class

/

000 0 VAC

00.00 A

0.00 kW

IP 00

/ 0

/Hz

Made in Šiauliai, Lithuania

SKU000000

LN: LN000000      2019.01.01

Product name

Nominal voltage frequency

Max.current

Max.power consumption

Protection class

/

000 0 VAC

00.00 A

0.00 kW

IP 00

/ 0

/Hz

Made in Šiauliai, Lithuania

SKU000000

LN: LN000000      2019.01.01

Product name

Nominal voltage frequency

Max.current

Max.power consumption

Protection class

/

000 0 VAC

00.00 A

0.00 kW

IP 00

/ 0

/Hz

Made in Šiauliai, Lithuania

SKU000000

LN: LN000000      2019.01.01

Product name

Nominal voltage frequency

Max.current

Max.power consumption

Protection class

/

000 0 VAC

00.00 A

0.00 kW

IP 00

/ 0

/Hz

Made in Šiauliai, Lithuania

SKU000000

LN: LN000000      2019.01.01

Product name

Nominal voltage frequency

Max.current

Max.power consumption

Protection class

/

000 0 VAC

00.00 A

0.00 kW

IP 00

/ 0

/Hz

Made in Šiauliai, Lithuania

SKU000000

LN: LN000000      2019.01.01

Figure 1.2 - VSA 3.0/VSA EKO technical lable place

Figure 1.3 - Indication for air flow direction.

GENERAL INFORMATION

Prior to the installation of the device it is necessary to read all the material presented in this document.

The device installation can be performed only by trained and qualified staff, familiar with this type of equipment installation, verification, maintenance 

and required tools for installation works.

If the provided material is unclear or there are any doubts concerning safe installation and use, please contact the manufacturer or his representative.

The device can only work under following conditions.

It is strictly prohibited to use the device not for its purpose or not under provided working conditions without receiving a written permit from the 

manufacturer or its representative.

In the event of failure, it must be reported to the manufacturer or its representative with the description of  the failure and provide data on product label.

In the event of a failure, it is prohibited to repair, disassemble the device without a written consent from the manufacturer or its representative.

The device can be disassembled, repaired or modified only after receiving a written consent from the manufacturer or its representative.

Before using the products manufactured or supplied by the company, the clients must ensure the products are compatible with the selected en

-

vironment.

TRANSPORTATION AND STORAGE

All devices are packed in the factory to withstand normal transportation conditions.

When unpacking the device, check if it has not been damaged during the transportation. It is prohibited to install damaged equipment!!!

The package is only a protection measure!

When unloading and storing the equipment, use proper lifting equipment to prevent damage and injuries. Do not lift the equipment on power ca

-

bles, connection boxes, air collecting or disposal flanges. Avoid shacking and punching overloads. Until the installation, store the devices in a dry 

place where relative humidity does not exceed 70% (at 20°C), the average ambient temperature – between 5°C and +30°C. Storage place has to 

be protected from dirt and water.

The devices have to be stored and transported only in a horizontal position so that the inlet flange would be at the bottom.

Storing for more than one year is not recommended. When storing longer than one year, it is necessary to verify if the bearings are rotating easily 

before the installation (rotate the impeller by hand)

PURPOSE OF THE DEVICE

The device is used in ventilation and air conditioning systems to pull only clean air from the room (free from metal corroding chemicals; aggressive 

substances for zinc, plastic, rubber; hard, sticky and fibrous particles).

DESCRIPTION

Fan rotation speed is controlled by changing voltage.

Maintenance undemanding bearings.

Automatic thermo contact engine protection. 

Содержание VSA 3.0 Series

Страница 1: ...VSA 3 0 VSA EKO EN MOUNTING AND INSTALLATION INSTRUCTION...

Страница 2: ...he manufacturer or his representative The device can only work under following conditions It is strictly prohibited to use the device not for its purpose or not under provided working conditions witho...

Страница 3: ...e use would be ensured The device can be connected to pull the air directly from the ventilated room fig 01 or from the air duct system fig 02 It is necessary to ensure protection from contacting work...

Страница 4: ...s and are connected to the electricity This may pose a risk to the human health and life That is why safety require ments have to be followed while installing If you have any doubts on the safety of t...

Страница 5: ...N line voltage 230V C C capacitor TK jumper YE GN BN PE N L BU N RD L YE GN yellow green RD red BN braun SP2 L 0k Protective earth PE L1 N line voltage 230V C C capacitor YE GN BN PE N L BU N RD L YE...

Страница 6: ...er but the device does not start do the following Wait 10 20 min until the engine cools down If the electrical current was not disconnected and after 10 20 min the engine starts itself this means that...

Страница 7: ...tection class IP 44 IP 44 IP 44 IP 44 IP 44 IP 44 wiring diagram 2 1 2 1 1 1 VSA EKO 190 220 225 250 phase voltage 50 Hz VAC 1 230 1 230 1 230 1 230 power kW 0 084 0 097 0 17 0 360 current A 0 66 0 77...

Страница 8: ...erage kWh 107 143 70 123 AEC cold kWh 107 143 70 123 AEC warm kWh 107 143 70 123 AHS Average kWh a 2830 2830 2830 2830 AHS Cold kWh a 5536 5536 5536 5536 AHS Warm kWh a 1280 1280 1280 1280 ErP Complia...

Страница 9: ...nt and risk reduction LST EN 60204 1 Safety of machinery Electrical equipment of machines Part 1 General requirements LST EN 60335 1 Household and similar electrical appliances Safety Part 1 General r...

Страница 10: ...the equipment to manufacturer Delivery costs should be covered by customer Manufacturer reserves the right to change this technical passport any time without prior notice if some typographic errors or...

Страница 11: ...11 VSA 3 0_VSA EKO v2019 04...

Страница 12: ...000152 UNIT S MAINTENANCE TABLE Product name lot number Instalation Interval Date Fan cleaning Once a year Heat exchanger cleaning Once a year Filter replacement Every 3 4 months Look at the product l...

Отзывы: