SMARTY XV v2020.2
TE
Exhaust air temperature sensor
SK2
TJ
Supply air temperature sensor
TL
Outdoor air temperature sensor
DTJ
extract air temperature and humidity sensor (only
version 1.1)
M
CO
2
Ventilated premises
CO
2
CO
2
sensor*
MB-Gateway
Network module
RH
RH sensor*
NET
Network
PC
Computer
RC
Stouch or SA-Control remote control panel
POSSIBLE PCB INPUTS/OUTPUTS
FA
Fire alarm
H1
Working indication output
FPP
Fireplace protection
H2
Alarm indication output
System mode switch (START/STOP)
Fans speed switch (BOOST)
* Component/posibility to connect it depends on model.
5.5. MOUNTING
•
Installation should only be performed by qualified and trained staff.
• When connecting air ducts, consider the labels on the casing of the unit.
• Before connecting to the air duct system, the connection openings of ventilation unit should be closed.
•
When connecting the ducts , you should pay attention to the air flow direction indicated on the device housing.
•
Do not connect the bends close to connection flanges of the unit. The minimum distance of the straight air duct between the unit and the first
branch of the air duct in the supply air duct must be 1xD, in air exhaust duct 3xD, where D is diameter of the air duct.
• It is recommended to use the accessories-holders. This will reduce vibration transmitted by the unit to the air duct system and environment.
•
Enough space must be left for opening of the maintenance door and filter covers.
• If the installed ventilation unit is attached to a wall, it may transmit noise vibrations to the premises. Though the level of noise caused by the
fans is admissible, it is recommended to mount the unit at the distance of 400 mm from the nearest wall. If it is not possible, the mounting of the
unit is recommended on the wall of the room where the level of noise is not important.
• Ducts are connected to the unit in such way that they could be easily disassembled and the heater could be removed from the unit when per-
forming service or repair works
The protective film is intended to protect the unit during transportation. It is recommended to remove the film because other
-
wise oxidation signs may occur.
Before every heating season the condensate tube shall be filled with water as indicated during the first startup!
W
α
W
α
α
W
α
W
α
α
Figure 5.5.1. mounting positions (W=400 mm)
Figure 5.5.2. mounting positions
Содержание SMARTY XV Series
Страница 1: ...SMARTY XV EN MOUNTING AND INSTALLATION INSTRUCTION...
Страница 23: ...EN 23 SMARTY XV v2020 2 EKA NIS connection...
Страница 30: ...30 EN SMARTY XV v2020 2 Figure 8 1 9 2 Smarty 2XV 1 1 Smarty 2XV 3XV 4XV 1 2 219 1017 0 1 2 PS...
Страница 31: ...EN 31 SMARTY XV v2020 2 C H C C H C Figure 8 1 9 3 Smarty 2XV 1 1 Smarty 2XV 3XV 4XV 1 2 219 1017 0 1 3 PS...
Страница 49: ...49 SMARTY XV v2020 2...
Страница 50: ...50 SMARTY XV v2020 2...
Страница 51: ...51 SMARTY XV v2020 2...