INSTALLATION GUIDE

Tools required

Pencil

Scotch Tape

Saw

Mounting foam

Drill 

Ø

 6 mm

Screwdriver

Dowel 4 pcs

Screws 4 pcs

AIR HANDLING UNIT WITH HEAT RECOVERY

FRESHBOX 100

400 mm

15

 

3/4

"

200 mm

7/8

"

257 mm

10 

1/8

"

590 mm

23

 

1/4

"

690 mm

27 

3

/

16

"

Ø 

100 mm (

Ø 

15/

16

")

3 holes

Содержание Freshbox 100

Страница 1: ...05 e mail info blauberg us INSTALLATION GUIDE Toolsrequired Pencil ScotchTape Saw Mountingfoam Drill Ø6mm Screwdriver Dowel4 pcs Screws4 pcs AIR HANDLING UNIT WITH HEAT RECOVERY FRESHBOX 100 400 mm 15 3 4 200 mm 7 7 8 257 mm 10 1 8 590 mm 23 1 4 690 mm 27 3 16 Ø 100 mm Ø 3 15 16 3 holes ...

Страница 2: ...een the wall and the air ducts with a mounting foam 4 holes Ø 8 5 16 and 90 mm 3 9 16 deep in the wall made using a mounting template 416 5 mm 16 3 8 647 mm 25 1 2 205 mm 8 1 16 162 mm 6 3 8 468 5 mm 18 7 16 102 5 mm 4 1 16 76 mm 3 400 mm 15 3 4 73 5 mm 2 7 8 547 mm 21 9 16 91 mm 3 9 16 230 mm 9 1 16 170 mm 6 11 16 188 5 mm 7 7 16 158 5 mm 6 1 4 77 mm 3 ADDITIONAL HOLE DRILL UPON CUSTOMER S REQUES...

Страница 3: ...the unit mounting place 2 Remove the mounting template and drill two through holes Ø 105 mm Ø 4 1 8 for round air ducts When mounting the unit with an additional extract spigot prepare a hole in the wall for a connecting bend and for laying of a rectangular air duct A connecting bend rectangular and round air ducts are available separately Drill holes Ø 8 mm Ø 5 16 90 mm 3 9 16 deep to mount the u...

Страница 4: ...l aligning the mounting template hole with a round end of the connecting bend Connect a rectangular duct to the connecting bend 4 Fill the spaces between the air ducts and the wall with a mounting foam through the specially designed holes in the mounting template Wait till a mounting foam hardens then take off the mounting template and remove the foam excess Cut off the protruding air duct parts t...

Страница 5: ...heat exchanger Remove the magnetic plug from the exhaust grille if an additional extract spigot is not installed 7 Fix the unit on the wall using the supplied screws and expansion anchors Install the heat exchanger back and close the unit door Cut a part of the drain pipe protruding outside to a length not more than 10 mm 3 8 Fix the outer hood on the outer wall of the building see the ventilation...

Страница 6: ...e not included in the scope of delivery Connection of additional external control contacts is implemented in the control unit For accessing the control unit open the unit door release the screws fixing the shielding and remove it Connection of the automatic fire fighting system contact PK Upon connecting the automatic fire fighting system contact remove the jumper between the terminals 5 and 6 Rem...

Отзывы: