![Salda RIS 700 H EKO 3.0 Скачать руководство пользователя страница 22](http://html1.mh-extra.com/html/salda/ris-700-h-eko-3-0/ris-700-h-eko-3-0_mounting-and-installation-instructions-manual_3711210022.webp)
22
| EN
RIS 700 H EKO 3.0 v2020.1
8.1.8. RECOMMENDED SCHEME FOR CONNECTION OF INTERNAL AND EXTERNAL COMPONENTS
1_791
-0
036A
.0
.1
.0
-L
-0
k
B
OOS
T
ST
AR
T
-N
C
ST
O
P
-N
O
Jumper
CO2; Extract air pressure
Air quality transmitter
Supply air pressure
Transmitter 2
26 - 24V DC,
27 - intput, 0-10V DC,
28 - GND,
X16.10
28
27
P
26
27 28
26
24 25
23
CE7/7
27 28
26
24 25
23
X16.7
PE N L1
L1
N
PE
L1
N
PE
L1
N
PE
1f, 230V AC
3RZHU
supply cable
valve actuator
Water cooler
1
3
2
X16.1
Y1 Y2 G
M5
24VAC, 3-position
Y1 - OPEN (24VAC)
Y2 - CLOSE (24VAC)
G - System potential 24VAC
1 2 3 4 5 6 7 8 9 10
10
9
8
7
6
5
4
3
2
1
Boost
Start/Stop
AHU status
$+8ZRUN
AHU stop
24
V
D
C
24
V
D
C
3
1
P
DX Cooling
X16.4
X16.4
X16.2
13 14
8
7
X16.3
A
HU s
to
p
1.
2W
m
ax
4
5
6
10
9
X16.4
1.
2W
m
ax
$
+8
ZR
UN
11 12
25
24
23 - 24V DC,
24 - intput, 0-10V DC,
25 - GND,
Transmitter 1
P
23
18 19 20 21 22
22
21
20
19
18
X16
17
16
15
14
13
12
11
NTC
Supply air
TJ
temp.sensor
21 22
X16.6
11 12 13 14 15 16 17
N
L
19
X16.5
M2
M3
17
18
L
N
N L L
16
20
15
230V AC
230V AC
ON/OFF
ON/OFF
L con
trol
N
L control
L
Supply air
Extract air
damper actuator
damper actuator
Fire alarm
input
Air quality transmitter
L
16
15
X16.2
HR
A4
A4
PUMP
AC.N
L
N
V1
COM
X12
X42
X37.2
X37.1
COM
V2
X37.3
X37.4
X4
X3
M
o
dB
us
R
T
U
RS
48
5
_2
RS485_2
A1
A1
A2
A2
A3
A3
TE
TE
X52
X33.19
X33.20 COM
T.WAT
TJ
X33.22
X33.21
X35.3
X35.4
X35.5
N
L supply
L control
N
N
N
EXT+
EXT-
EXT-
EXT+
L control
L (open)
AC.N
EXT+
EXT-
X10
X33.13
N
L (close)
COM
X8
L
N
RS485_1
T.OUT
COM
TJ
PE
term
inal
RS
48
5
_1
Re
m
ote
c
o
n
tro
l
RG
1
TA
13
14
22
21
X16.6
X
16.
5
M2
M3
19
17
1
8
L
NN
L
L
20
L supply
230V AC
230V AC
ON/OFF
ON/OFF
L
X37
TL
N
PE
L
1
1
3
4
2
LOW X32.1
COM X32.4
HIGH
X32.2
TIME
X32.3
COM
X33.15
MIDL
X33.2
CHIL X33.9
COM X33.10
BOOST
STOP-NO
START-NC
A2
A1
R1
8
7
X16.3
ALARM X33.11
COM
ANTI.F
Fan fall
1.2W max
45
6
10
9
X16.4
+24
1.2W max
Fan run
11
1
2
COM
FAN
25
24
P
23
X29
X25
N
L
F1
3
1
P
DX
Co
oli
ng
B.0.10
COM
14
11
G
M5
24V
A
C
, 3-
pos
itio
n
Y2
Y1
VAL
VAL-
VAL+
X33.3
X33.4
X33.5
3
12
X1
6.
1
24V
D
C
Y
1
- C
ont
ro
l O
P
E
N
(A
C
24
V
)
Y
2
- C
ont
ro
l C
LO
S
E
(A
C
24
V
)
G
- S
ys
tem
pot
ent
ia
l A
C
24
V
X35.2
X35.1
X33.13
X33.14
X33.18
X33.12
X33.17
X33.25
X33.26
X34.1
X34.2
X34.3
X34.4
X34.5
X34.6
X34.7
X34.8
X40.1
X40.2
X40.3
X38.2
X38.1
X39.1
X39.2
X41.2
X41.1
24VDC
24VDC
A.0.10
COM
X33.16
X33.15
X31
L
Q
1
0
DLQ
6
Z
LWF
K
2P
X24
N
X16.7
L1
N
PE
23
0V AC, 50Hz
W1
10
A
CEE7/7
3x1,5
X33.22
X33.21
COM
T.set
28
27
P
26
X16.10
W1
Ju
m
per
Tr
an
sm
itte
r 1 (
24 V
D
C
)
23
-
2
4
V
D
C
,
2
4 -
in
tput
, 0-
1
0V
D
C
,
2
5 -
G
ND,
Tr
ans
m
itter
2
(2
4
V
D
C
)
26
-
2
4
V
DC,
27
-
in
tp
ut
, 0-
10
V
D
C
,
28
-
G
ND,
X4
6
PE
N
L3
L1
L2
L2
L1
L3
N
PE
1
2
3
4
5
0
-10V
in
-
GN
D
IV
L
N
PE
+
L
N
PE
PE
N
L
+
PE
N
L
PV
GND
-
0
-10V
in
X32
X3
3
B
K
-
b
lack
,
R
D
- re
d,
WH
-
w
hit
e.
12
DMP-
DMP+
DMP
X33.7
X33.6
X33.8
24
V
A
C
3-
po
sit
io
n
M1
1 - GND
2 - AC24V open
3 - AC24V close
3
2
1
X2
1
6,
3A
F2
1
2
C
2
1
AT
1
RT
1
C
1
2
X0
2
X0
1
A2
A1
5
4
6 7 8 9
X22.2
12
34
5
X2
9
.1
1x
12
00W
/23
0V
KE
1
A2
A1
PWM
0
TK
TK
RG
2
3
12
2
1
Lin
Lout
X29.2
9
8
7
6
4
3
2
1
X2
2
.1
RD
WH(BK)
YE
GN(BU)
EK
P
V
- s
upp
ly
ai
r f
an E
C
,
IV
-
e
xtr
ac
t a
ir fa
n E
C
,
T
L -
o
uts
id
e
a
ir t
em
p
er
at
ur
e s
ens
o
r,
T
J -
s
u
ppl
y a
ir t
e
m
p
er
at
ur
e s
ens
or
,
T
E
-
ex
ha
us
t a
ir t
em
p
er
at
u
re
sens
o
r,
D
T
J1
00
- ex
tra
ct ai
r h
um
id
ity
+
t
em
per
at
ur
e s
en
sor
,
M
1
- B
Y
P
A
S
S
dam
pe
r ac
tu
a
to
r, 3-
pos
itio
n
(int
e
gr
at
ed)
M
2
- out
sid
e ai
r da
m
per
a
ctu
at
or
,
M
3
- ex
trac
t a
ir dam
pe
r ac
tu
a
to
r ,
0
Z
D
WH
UF
RR
OH
UY
DOY
H
DF
WX
D
WR
U
3
'
;
F
RR
OH
USU
RW
HF
WLR
Q
GL
IIH
UH
QW
LDO
S
UH
VV
XU
H
VZ
L
tc
h,
F
A
-
fi
re
a
la
rm
in
p
ut,
T
ra
ns
sm
ite
r.
.. - a
ir q
uo
lity
t
ra
m
sm
itte
r.
R
G
1
- c
o
nt
ro
ller
P
R
V
R
P
-V
2.
2,
K
E
1 -
s
upp
ly
ai
r he
at
er
.
A
T
1 -
a
ut
om
at
ic
r
es
et
th
er
m
os
tat
s
u
ppl
y a
ir hea
te
r.
R
T
1
- m
anu
al
r
es
e
t t
h
er
m
os
tat
s
u
ppl
y ai
r hea
te
r.
F
... -
F
us
e BT
-5
x2
0-
...A
,
R1
-
re
la
y.
FA
NC
Ju
m
pe
r
FA
NC
Jumper
+5V
TA
COM
RH
RD
WH
YE
GY
HR
U
TA
D
T
J 100
.1
3
2
1
BK
R
D
WH
Figure 8.1.8.1.
5,6+((.2
Содержание RIS 700 H EKO 3.0
Страница 1: ...RIS 700 H EKO 3 0 EN MOUNTING AND INSTALLATION INSTRUCTION...
Страница 21: ...EN 21 RIS 700 H EKO 3 0 v2020 1...