background image

EN |

 13

KUB T120_KUB EKO v2019.04

WARRANTY

1. All equipment manufactured in our factory is checked in operating conditions and tested befor delivery. Test protocol is supplied together with 

the unit. The equipment is shipped in good working order and condition to the direct client. The unit is warrantied for the period of two years from 

the invoice date.

2. If equipment is found to have been damaged during transportation, a claim should be made against carrier, as we assume no responsibility for 

such damage.

3. This warranty does not apply:

3.1. when transportation, storage, installation and maintenance instructions of the unit are violated;

3.2. when the equipment is improperly maintained, mounted - inadequate maintenance; 

3.3. when the equipment without our knowledge and permission has been upgraded or unskilled repairs were made;

3.4. when the unit was used not for its original purpose.

3.5. Company SALDA UAB is not responsible for potential loss of property or personal injury in cases where AHU is manufactured without a con

-

trol system and the control system will be installed by the client or third parties. The manufacturer’s warranty does not cover devices that will be 

damaged by installing the control system.

4. This warranty does not apply at these malfunction cases:

4.1. mechanical damage; 

4.2. damage caused by entering outside objects, materials, liquids; 

4.3. damage caused by natural disaster, accident (voltage change in the electricity network, lightning, etc..).

5. The company assumes no liability for its products either directly or indirectly damage, if the damage is caused by failure to comply with instal

-

lation and mounting regulations, deliberate or careless users or third-party behavior.

These conditions are readily discernable when the equipment is returned to our factory for inspection.

If the direct client determines that equipment is found to be faulty, or a breakdown occurred, he should inform the manufacturer within five working 

days and deliver the equipment to manufacturer. Delivery costs should be covered by customer.

Manufacturer reserves the right to change this technical passport any time without prior notice, if some typographic 

errors or inaccurate information is found, as well as after improving the apps and/or the devices. Such changes will be 

included in the new issues of the technical passport. All illustrations are just for information and thus may differ from the 

original device.

20.1. LIMITED WARRANTY COUPON

Warranty term

24 months*

I received complete package and technical manual of the product ready for usage. I have read warranty terms and conditions and agree with them: 

 

..........................................................................................................................................................................

Customer’s signature

*refer to WARRANTY CONDITIONS

D

ear User, we appreciate your choice and do hereby guarantee that all ventilation equipment manufactured by our Company is inspected and 

thoroughly tested. An operational and high-quality product is sold to the direct buyer and shipped from the territory of the factory. It is provided with 

a 24-month warranty since invoice issue date.

Your opinion is important to us, thus we always look forward to hearing your comments, feedback, or suggestions regarding technical and opera

-

tional characteristics of the Products.

In order to avoid any misunderstandings, please read the instructions for installation and operation of the product as well as other technical docu

-

ments of the product carefully. The number of the Limited Warranty Coupon and serial number of the product specified on the silver identification 

sticker attached to the housing must match. 

The Limited Warranty Coupon shall be valid provided that the seller’s stamps and records are clear. It is prohibited to change, delete, or rewrite 

the data specified on it in any manner – such a coupon shall be invalid.

With this Limited Warranty Coupon the manufacturer confirms one’s obligations to implement the imperative requirements established by effective 

laws on protection of consumer rights in the event of identification of any defects of the products.

The manufacturer reserves the right to refuse provision of free warranty servicing in cases when the warranty conditions listed below are disre

-

garded.

Содержание KUB EKO

Страница 1: ...KUB T120 KUB EKO EN MOUNTING AND INSTALLATION INSTRUCTION ...

Страница 2: ...product is installed and used If the provided information is unclear or any doubts arise regarding safe installation and operation please contact the manufacturer or represent ative The unit shall be operated only under the below listed conditions It is strictly forbidden to use the unit for non designed purposes or in contradiction to the specified working conditions without written permission of...

Страница 3: ...c wall insulation of 25 mm ATTENTION It is necessary to use filter before the fan PURPOSE OF THE DEVICE Fan kitchen box ins is used in ventilation systems to extract air from the room free from metal corroding chemicals aggressive substances for zinc plastic rubber hard sticky and fibrous particles Fan box insulated is designed for ventilation and conditioning systems to supply extract to from a r...

Страница 4: ...erature Co 40 40 40 40 40 40 min ambient temperature Co 40 40 40 40 40 40 weight kg 33 55 62 66 98 138 motor protection class IP 55 IP 55 IP 55 IP 55 IP 55 IP 55 wiring diagram 1 22 1 22 1 1 22 1 22 3 1 Speed is controlled only with the frequency inverter Motors sandard IE2 2 The provided technical data is by using 1 el connection scheme Using 2 el connection scheme technical data will be differen...

Страница 5: ...rn the impeller by hand MECHANICAL CONECTION Installation works shall be performed only by trained and qualified personnel Unit shall be installed firmly and tightly to ensure safe operation Do not connect the elbows in vicinity of the connection flanges of the unit The minimum distance of the straight air duct between the unit and the first branch of the air duct in the suction air duct must be 1...

Страница 6: ...otection devices of the motor Before start up of the fan make sure that the above instructions of safety and installation are applied Upon start up of the unit make sure that the motor rotates evenly without vibration and outside noise Upon start up of the unit make sure that the air flow generated by the unit matches the direction s of air indicated on the casing The current used by the motor sha...

Страница 7: ...hermal protection was activated Find the cause for motor overheating and eliminate it The fan motor with thermo contact protection stops because of overheating and external protection is activated Allow the motor to cool down for 15 20 minutes Correct the cause for motor overheating Switch the fan again The motor does not switch on again Disconnect the supply voltage Ensure that the impeller is no...

Страница 8: ...al output function Ready to run 0 Not ready 1 Digital output auxiliary voltage Digital input output common Output frequency Speed reference 0 10 V Analog input circuit common Two wire sensor transmitter Analog input circuit common Output frequency 0 20 mA Analog output circuit common Signal cable shield screen Reference voltage Relay output 1 No fault Fault 1 Embedded Modbus RTU EIA 485 L1 L2 L3 1...

Страница 9: ...l output function Ready to run 0 Not ready 1 Digital output auxiliary voltage Digital input output common Output frequency Speed reference 0 10 V Analog input circuit common Two wire sensor transmitter Analog input circuit common Output frequency 0 20 mA Analog output circuit common Signal cable shield screen Reference voltage Relay output 1 No fault Fault 1 Embedded Modbus RTU EIA 485 L1 L2 L3 1 ...

Страница 10: ...ė UAB SAL Lapas Raidė Data Para as Dok Nr Lapas Keit Ventiliatori jungimas 1 3 5 2 4 6 TK TK PE PE L1 L2 L3 TK TK PE L3 L2 L1 U1 V1 W2 U2 3xNC 140 C 500 V AC 2 5 A L1 L2 PE TK TK W1 L3 V2 3f 400V 1 3 5 2 4 6 TK TK PE PE L1 L2 L3 TK TK PE L3 L2 L1 U1 V1 W2 U2 L1 L2 PE TK TK W1 L3 V2 3f 230V 3xNC 140 C 500 V AC 2 5 A KUB 3 KUB 4 KUB 2 1f 230V 1 3 2 4 TK TK PE PE L1 L2 TK TK PE N L U1 V1 W2 U2 NC 140...

Страница 11: ...1 52 2 98 SFPint W m3 s N A N A N A N A N A N A Face velocity m s 0 0 0 0 0 0 Normal external pressure Pa 580 422 493 448 494 600 Internal pressure drop of ventilation compo nents Pa N A N A N A N A N A N A Static efficiency of fans used in accordance with Regulation No 327 2011 57 8 48 4 52 1 49 7 54 51 8 Declared maximum external leakage 1 1 1 1 1 1 Casing sound power level Lwa dB A 76 57 59 62 ...

Страница 12: ...ent and risk reduction LST EN 60204 1 Safety of machinery Electrical equipment of machines Part 1 General requirements LST EN 60335 1 Household and similar electrical appliances Safety Part 1 General requirements LST EN 60529 Degrees of protection provided by enclosures IP code LST EN 60034 5 Rotating electrical machines Part 5 Degrees of protection provided by the integral design of rotating elec...

Страница 13: ... the equipment to manufacturer Delivery costs should be covered by customer Manufacturer reserves the right to change this technical passport any time without prior notice if some typographic errors or inaccurate information is found as well as after improving the apps and or the devices Such changes will be included in the new issues of the technical passport All illustrations are just for inform...

Страница 14: ...14 KUB T120_KUB EKO v2019 04 ...

Страница 15: ... 15 KUB T120_KUB EKO v2019 04 ...

Страница 16: ...AN000151 UNIT S MAINTENANCE TABLE Product name lot number Instalation Interval Date Fan cleaning Once a year Heat exchanger cleaning Once a year Filter replacement Every 3 4 months Look at the product label At least NOTE The purchaser is required to fill in the Product maintenance table ...