8.  Check the marker arrows on the pump to ensure correct direction of water flow.  

Either end of the pump is suitable for hot or cold water.

9.  Check the static inlet pressure does not exceed 10m max (1.0bar/100kPa) of water  

above the pump.

10.  The hot supply pipework to the pump should be a maximum length of 5 metres in 22mm pipe 

(hot and cold supplies should be no more than 2 metres in 15mm pipe).

11.  Exclusive hot and cold supplies to the pump with the hot from a Salamander approved method. 

Exceptions, only when pump is at the base of the cylinder and within 5m, are:

 

•   hot supply–from the vent angled at 45º, vertically down the hot connection at the vent, 

at least 1.5 metres below the base of the cold water storage cistern (Figure 6).

 

•   alternatively, the hot and cold supplies to the pump can be teed off other 22/28mm 

supplies (Figure 7) provided that:

 

  •  the tee off to the pump is first call on the downward leg after the vent connection.

 

  •  the cold supply to the pump is not shared with the cold feed to the cylinder.

12.  The best hot connection from the cylinder (figure 3) is either with:

¾

 inch no stop Essex flange, or a Salamander S flange or other approved top entry flange.

13.  Check that water storage capacity recovery meets required flow rates, particularly at peak 

demand (i.e. appliances in simultaneous use).

14.  All up and over pipework must be vented at the highest point on the outlet of the pump.
15.  Ensure that pipe runs minimise airlocks.
16.  In positive head systems, allow for increased resistance of long pipe runs with multiple bends. 

The natural flow from the shower head or other outlets must be at least 2litres/minute at all 

times. Any supply where the natural flow is less than 2litres/minute is classed as a negative 

head situation.

Step 1: Pump location

1.  Site the pump in a location where it will not freeze or be exposed to frost during cold weather.
2.  Ensure adequate airflow to cool the motor. Separate the pump from other appliances that 

generate heat. Install the pump in a clear space allowing 100mm at each side, end and top.

3.  Care must be taken not to endanger pre-existing electrics when siting your Salamander pump 
4.  Ensure the pump is as close to the hot water cylinder as possible & no more than 5m in 

measured pipework away.

5.  Mount the pump upright (shaft horizontal, not screwed down).
6.  An anti-gravity loop (AGL) of at least 400mm (ideally using swept bends) must be used 

when the pump is sited above the dome of the hot water cylinder as it prevents air tracking 

up into the pump chamber and back siphoning of the water again, creating air in the pump 

chamber. An approved side or top entry flange must be used in these circumstances for the 

hot water connection to the cylinder, with the Essex or alternative side entry flange being the 

recommended method of connection. If the pump experiences aeration or low pressure as 

result of poor flow to the pump with the use of a top entry flange, a side entry or Essex flange 

may become a requirement. 

7.  Bathroom Zones: Salamander products covered in these notes cannot be installed  

in Zone 0 or Zone 1. They can however be installed in areas that are accessible with  

a tool. (See figure 5)

 

The pump should be installed in accordance with BS7671:2018. 

 

In BS7671:2018 rooms containing baths or showers should be broken down into zones.

 

These zones are summarised as: 

 

ZONE 0 – This is the bath or shower tray

 

ZONE 1 – Is considered to be the area where the individual is bathing or showering 

or the area where shower water is likely to be directly sprayed.

 

ZONE 2 – Is the area beyond Zone 1, extending by a further 600mm.

 

Please refer to BS7671:2018 for further guidance.

Outside

Zones

Outside

Zones

Zone 0

Zone 1

Zone 2

Outside Zone
Space under bath is Zone 1

if accessible without tool

Window recess Zone 2

2

2

2

2

2

1

1

0.6m

0.6m

2

Outside

Zones

Outside

Zones

Outside Zones

2

2

2

2

2

1

0

Zone 0

Zone 1

Zone 2

Outside Zone
Space under bath is Zone 1

if accessible without tool

Window recess Zone 2

0.6m

0.6m

Outlet

Inlet

Outlet

Maximum 5 metres from vent to pump

(only 2 metres in 15mm pipe)

Cold 

water 

storage

2 litres/min

natural flow

Minimum 

1.5 metres

MAX

65°C

Cold water storage

Inlet

Outlet

Inlet

Outlet

Usable capacity

Minimum 50 gallons

per bathroom

600mm or

less possible

negative head

Positive head

Other

supplies

Vent

Other services

MAX

60°C

MAX

65°C

1st tee off

downward leg

Figure 5: Bathroom Zones

Figure 6. Exclusive hot and cold supply

Figure 7. Tee off other supplies

*

*Vent and expansion pipe to terminate to current standards

*

Содержание CT Force

Страница 1: ...Pump installation and warranty guide for the CT range of pumps CT Force CT Xtra and CT Bathroom ISSUE H JAN 2019 Models shown CT FORCE 15TU CT50 Xtra CT60B ...

Страница 2: ...rouble free system It is therefore important to read these instructions thoroughly and ensure you comply with them Incorrect fitting will invalidate the warranty If your installation is complicated or you have any questions please CONSULTTHE PUMPWISE TECHNICAL HELPLINE IMMEDIATELY on 0191 516 2002 01844 3212 ROI DO NOT REMOVE YOUR PUMP FROM THE SYSTEM WITHOUT FIRST RINGING PUMPWISE ON 0191 516 200...

Страница 3: ...inder within 5m of measured pipe 2m MAX of 15mm pipework on inlet connections may be used Allow 100mm on all sides for ventilation Ensure pump is protected from frost If servicing two or more bathrooms cold water supply to the cylinder must be in 28mm pipework Ensure adequate cold water storage 227 litres 50 gal per bathroom 364 litres 80 gal for one bathroom and one en suite Cold water supplies t...

Страница 4: ...T FORCE 20 PS 20 IPS 30 PS 30 IPS CT Xtra 55 55 59 85 85 89 are positive single impellor pumps Inlets and outlets must be vertical and plumbed appropriately It is essential to ensure that The cold stored water capacity is adequate for the entire household requirements eg minimum 136 litres 30 gal for shower only 227 litres 50 gal per bathroom or 364 litres 80 gal for one bathroom plus an en suite ...

Страница 5: ... pump is as close to the hot water cylinder as possible no more than 5m in measured pipework away 5 Mount the pump upright shaft horizontal not screwed down 6 An anti gravity loop AGL of at least 400mm ideally using swept bends must be used when the pump is sited above the dome of the hot water cylinder as it prevents air tracking up into the pump chamber and back siphoning of the water again crea...

Страница 6: ...ow of water goes to the outlet because either the outlet or the pipework to the outlet are above the height of the base of the cold water cistern Most instances of negative head systems occur in loft conversions or where the cold water cistern sits on the joists in the loft If the distance between the bottom of the cold water cistern and the highest point in the system after the pump is 2 feet 610...

Страница 7: ...e done during commissioning Step 2 Connecting the pump Use only Salamander supplied AV couplers to connect the pump All associated pipework MUST be thoroughly flushed before making final connections to the pump Fill the pump with water before connecting to the discharge pipework The in line strainers must be fitted to the hot and cold inlet supplies to the pump A Hose to pipework The anti vibratio...

Страница 8: ...ll valve is positioned above the cold feeds to the cylinder and to the pump aerated water is drawn into the pump as illustrated Chronic aeration of the pump occurs when this problem is combined with inadequate storage capacity and or when the volume of water is drawn by the pump and other services exceeds the refill rate and creates a vortex which draws air and possibly debris into the pump Cold s...

Страница 9: ...e g Aga solid fuel appliance or very crudely by the boiler thermostat a Salamander approved HWS TMV must be used Approved flanges cylinders The 22mm No Stop Essex and the other approved top entry flanges with extension pipes into the cylinder represent the best known means of ensuring minimal aeration of the hot supply water to the pump Please contact PumpWise on 0191 516 2002 for additional appro...

Страница 10: ... Fully automatic flow operated requiring 1ltr in 30 sec per side or 2ltr in 30 sec mixed Only applies to positive head pumps Temperature Maximum fluid temperature 65ºC Pump noise Salamander has engineered this product range to be as quiet as possible however no pump is completely silent Correct installation anti vibration couplers straight rubber feet fitted will minimise noise vibration and trans...

Страница 11: ... prior notice The CT Xtra and CT Bathroom ranges of pumps are fully WRAS approved CT Xtra has also been awarded Quiet Mark Part No Description Specification Performance Connection Type Pump Volumetrics Packed Pump Volumetrics Electrical Input Pump Type Pump Hoses Isolators Dimensions Dimensions CT FORCE Force 15PT Force 15IPT 1 5 Bar Twin End Positive Head Shower Pump 3A 110 1 1 130 1 3 150 1 5 22...

Страница 12: ...9 Xtra 2 5 Bar Single End Positive Head Shower Pump 3A 170 1 7 200 2 0 220 2 2 21mm 3 86 185 120 160 4 59 293 213 226 Fuse 230 1 50 Regenerative Pressure kPA Bar at 16ltr min Pressure kPA Bar at 8tr min Max pressure kPA Bar closed head BSP Push Fit Isolators intergrated into the hoses Weight Kg Length mm Width mm Height mm Weight Kg Length mm Width mm Height mm TechnicalSpecifications CTXtraH HU C...

Страница 13: ...vice Line Reduced intermittent flow Incorrect or no anti aeration flange fitted Fit appropriate anti aeration flange Insufficient gravity flow See above Blocked inlet filters Ensure that all filters and shower head are free from debris Couplers restricting flow Ensure that all AV couplers are straight and not bent or distorted Air in system Run system on full hot with pump switched off i e gravity...

Страница 14: ...ect to the terms and conditions below for the Warranty period s specified in paragraph 3 that the Company shall Repair or replace free of charge the product s specified on the Online Warranty Registration or Telephone Warranty Registration any component part thereof together referred as the equipment which shall in the opinion of the Company have proved defective by reason only of the Company s ma...

Страница 15: ...mpany 5 years from date of purchase provided the warranty is completed online or over the phone within 15 days of purchase Pumps purchased prior to 1st January 2016 come with 2 years warranty iii CT Xtra CT Bathroom UK only products manufactured by the Company 3 years from date of purchase provided the warranty registration is completed online or over the phone within 15 days of purchase iv CT Xtr...

Страница 16: ...28 29 Notes Notes ...

Страница 17: ...ter your warranty Apply online at www salamanderpumps co uk Apply by phone 0191 516 2002 Unit 2c Colima Avenue Enterprise Park West Sunderland SR5 3XE Get in touch we re here to help call us on 0191 516 2002 ...

Отзывы: