Salamander PumpWise is your guarantee to:
•  help you select the right pump for the job.
•  avoid installation pitfalls.

PumpWise helpline 0191 516 2002

PumpWise from Salamander helps customers and provides a support service second to none. 

Installers and customers can be sure of a speedy response to requests for technical help, 

guidance and advice.

Safety in operation

These appliances are not intended for use by persons (including children) with reduced 

physical, sensory or mental capabilities, or lack of experience and knowledge, unless they 

have been given supervision or instruction concerning use of the appliance by a person 

responsible for their safety.
Children should be supervised to ensure that they do not play with the appliance

Trouble Shooting

CHECK THAT THE INSTALLATION COMPLIES WITH THE SALAMANDER INSTRUCTIONS IF THE 

PUMP IS STILL INOPERABLE, CONTACT PUMPWISE ON 0191 516 2002.

Fault

Probable cause

Recommended solution

Pump will not start

Insufficient gravity flow

Check suitability of pump – is installation in negative head
(see page 8)
Check inlet filters are not blocked
Check flow rate (min of 2l/min required on both hot and cold)

Inlet/outlet connections incorrect

Check that connections are plumbed the correct way round
and all valves are open

Electrical

Check power supply
Check fuse
Check circuit breaker

Debris under flow switch

Remove outlet hoses and check that flow switch sits in lowest
position

Float sticking in outlet

Ensure no debris is in outlet area

Flow switch malfunction

Contact Technical Advice Line

Reduced/ intermittent flow

Incorrect or no anti-aeration 

flange fitted

Fit appropriate anti-aeration flange

Insufficient gravity flow

See above

Blocked inlet filters

Ensure that all filters and shower head are free from debris

Couplers restricting flow

Ensure that all AV couplers are straight and not bent or distorted

Air in system

Run system on full hot with pump switched off (i.e. gravity only)
for several minutes
Check cold water storage is correct for installation
Ensure cold water refill rate is adequate for installation
Check that vents are fitted as described in instructions

Wrong size pump for system

Ensure pump is sufficient to run the equipment

Hot temp set too high

Reduce cylinder stat setting to 65ºC max or fit HWS/TMV

Pump starts with all outlets 

closed

Leak in system

Check for leaks

Outlet open

Ensure all outlets are fully closed or capped – i.e. no dead legs 

in pipework

Pump is noisy

Air in system

See above

Pump vibrating on surface

Ensure rubber feet are fitted to pump

AV couplers causing vibration

Ensure that all AV couplers are straight and not bent or distorted

Pump is leaking

Pump exposed to mains water 

pressure

Fit break cistern or remove from mains supply

Pump has suffered chemical 

damage

Ensure that the pump has not come into contact with chemical
substance i.e. solder flux

Pump exposed to excessive
temperature

Is effective temp control fitted (cylinder stat or HWS/TMV 

valve)?

Pump appears to have leaked but
not sure

Check leak is not from fitting in pipework above pump

Pumps above hot cylinder 

becomes noisy/low 

pressure during use

Aeration or water stavation

An essex flange may be required for the hot connection to 

cylinder. Ensure pump is a minimum of 600mm below the cold 

water tank. 

Содержание CT Force

Страница 1: ...Pump installation and warranty guide for the CT range of pumps CT Force CT Xtra and CT Bathroom ISSUE H JAN 2019 Models shown CT FORCE 15TU CT50 Xtra CT60B ...

Страница 2: ...rouble free system It is therefore important to read these instructions thoroughly and ensure you comply with them Incorrect fitting will invalidate the warranty If your installation is complicated or you have any questions please CONSULTTHE PUMPWISE TECHNICAL HELPLINE IMMEDIATELY on 0191 516 2002 01844 3212 ROI DO NOT REMOVE YOUR PUMP FROM THE SYSTEM WITHOUT FIRST RINGING PUMPWISE ON 0191 516 200...

Страница 3: ...inder within 5m of measured pipe 2m MAX of 15mm pipework on inlet connections may be used Allow 100mm on all sides for ventilation Ensure pump is protected from frost If servicing two or more bathrooms cold water supply to the cylinder must be in 28mm pipework Ensure adequate cold water storage 227 litres 50 gal per bathroom 364 litres 80 gal for one bathroom and one en suite Cold water supplies t...

Страница 4: ...T FORCE 20 PS 20 IPS 30 PS 30 IPS CT Xtra 55 55 59 85 85 89 are positive single impellor pumps Inlets and outlets must be vertical and plumbed appropriately It is essential to ensure that The cold stored water capacity is adequate for the entire household requirements eg minimum 136 litres 30 gal for shower only 227 litres 50 gal per bathroom or 364 litres 80 gal for one bathroom plus an en suite ...

Страница 5: ... pump is as close to the hot water cylinder as possible no more than 5m in measured pipework away 5 Mount the pump upright shaft horizontal not screwed down 6 An anti gravity loop AGL of at least 400mm ideally using swept bends must be used when the pump is sited above the dome of the hot water cylinder as it prevents air tracking up into the pump chamber and back siphoning of the water again crea...

Страница 6: ...ow of water goes to the outlet because either the outlet or the pipework to the outlet are above the height of the base of the cold water cistern Most instances of negative head systems occur in loft conversions or where the cold water cistern sits on the joists in the loft If the distance between the bottom of the cold water cistern and the highest point in the system after the pump is 2 feet 610...

Страница 7: ...e done during commissioning Step 2 Connecting the pump Use only Salamander supplied AV couplers to connect the pump All associated pipework MUST be thoroughly flushed before making final connections to the pump Fill the pump with water before connecting to the discharge pipework The in line strainers must be fitted to the hot and cold inlet supplies to the pump A Hose to pipework The anti vibratio...

Страница 8: ...ll valve is positioned above the cold feeds to the cylinder and to the pump aerated water is drawn into the pump as illustrated Chronic aeration of the pump occurs when this problem is combined with inadequate storage capacity and or when the volume of water is drawn by the pump and other services exceeds the refill rate and creates a vortex which draws air and possibly debris into the pump Cold s...

Страница 9: ...e g Aga solid fuel appliance or very crudely by the boiler thermostat a Salamander approved HWS TMV must be used Approved flanges cylinders The 22mm No Stop Essex and the other approved top entry flanges with extension pipes into the cylinder represent the best known means of ensuring minimal aeration of the hot supply water to the pump Please contact PumpWise on 0191 516 2002 for additional appro...

Страница 10: ... Fully automatic flow operated requiring 1ltr in 30 sec per side or 2ltr in 30 sec mixed Only applies to positive head pumps Temperature Maximum fluid temperature 65ºC Pump noise Salamander has engineered this product range to be as quiet as possible however no pump is completely silent Correct installation anti vibration couplers straight rubber feet fitted will minimise noise vibration and trans...

Страница 11: ... prior notice The CT Xtra and CT Bathroom ranges of pumps are fully WRAS approved CT Xtra has also been awarded Quiet Mark Part No Description Specification Performance Connection Type Pump Volumetrics Packed Pump Volumetrics Electrical Input Pump Type Pump Hoses Isolators Dimensions Dimensions CT FORCE Force 15PT Force 15IPT 1 5 Bar Twin End Positive Head Shower Pump 3A 110 1 1 130 1 3 150 1 5 22...

Страница 12: ...9 Xtra 2 5 Bar Single End Positive Head Shower Pump 3A 170 1 7 200 2 0 220 2 2 21mm 3 86 185 120 160 4 59 293 213 226 Fuse 230 1 50 Regenerative Pressure kPA Bar at 16ltr min Pressure kPA Bar at 8tr min Max pressure kPA Bar closed head BSP Push Fit Isolators intergrated into the hoses Weight Kg Length mm Width mm Height mm Weight Kg Length mm Width mm Height mm TechnicalSpecifications CTXtraH HU C...

Страница 13: ...vice Line Reduced intermittent flow Incorrect or no anti aeration flange fitted Fit appropriate anti aeration flange Insufficient gravity flow See above Blocked inlet filters Ensure that all filters and shower head are free from debris Couplers restricting flow Ensure that all AV couplers are straight and not bent or distorted Air in system Run system on full hot with pump switched off i e gravity...

Страница 14: ...ect to the terms and conditions below for the Warranty period s specified in paragraph 3 that the Company shall Repair or replace free of charge the product s specified on the Online Warranty Registration or Telephone Warranty Registration any component part thereof together referred as the equipment which shall in the opinion of the Company have proved defective by reason only of the Company s ma...

Страница 15: ...mpany 5 years from date of purchase provided the warranty is completed online or over the phone within 15 days of purchase Pumps purchased prior to 1st January 2016 come with 2 years warranty iii CT Xtra CT Bathroom UK only products manufactured by the Company 3 years from date of purchase provided the warranty registration is completed online or over the phone within 15 days of purchase iv CT Xtr...

Страница 16: ...28 29 Notes Notes ...

Страница 17: ...ter your warranty Apply online at www salamanderpumps co uk Apply by phone 0191 516 2002 Unit 2c Colima Avenue Enterprise Park West Sunderland SR5 3XE Get in touch we re here to help call us on 0191 516 2002 ...

Отзывы: