Salamander Pumps CT Force Series Скачать руководство пользователя страница 27

25

To the installer

Please follow the guidelines for installation provided in this brochure and call the PumpWise 

helpline for installation advice.

Once the installation has been completed and the system has been tested to your satisfaction, 

please assist the customer in completing the prepaid Warranty Card.

Please note that Salamander Pumps are able to provide an onsite service visit which may be 

chargeable.

1  The Scope of the Warranty

 

SALAMANDER PUMPED SHOWER SYSTEMS LTD (“the Company”) Warrants subject to the 

terms and conditions below for the Warranty period(s) specified in paragraph 3 that the 

Company shall:

 

Repair or replace free of charge the product(s) specified on the Warranty card or any 

component part thereof (together referred as “the equipment”) which shall in the opinion 

of the Company have proved defective by reason only of the Company’s materials or 

workmanship. The Company shall be under no obligation whatsoever under this Warranty 

to repair or replace equipment which has been misused, tampered with, or modified/altered 

in any way without the consent in writing from the Company; or if any component or 

accessory has been replaced by a type not specified by the Company; or if the equipment is 

incorrectly installed, operated or used other than as described in the instruction manual; or if 

any servicing or repair of the equipment shall have been carried out by anyone other than an 

authorised Company dealer appointed by the Company (“dealer”).

 

The Company’s liability under this Warranty is limited to the said repairs or replacement and 

shall under no circumstances extend to any financial loss or damage including consequential 

losses alleged to have been suffered by the claimant.

 

Subject as provided in this warranty and except where the equipment is sold to a person 

dealing as a consumer all warranties, conditions or other terms implied by law are excluded 

to the fullest extent permitted by law.

 

Nothing in this warranty shall exclude liability for death or personal injury caused by the 

Company’s negligence.

2  Terms and conditions

 

This Warranty shall only be enforceable by you if the following terms and conditions have 

been complied with:

 

a.   That the pump has been installed in accordance with the installation instructions, 

guidance and advice contained within the installation and warranty guide and/or 

provided by the Salamander help desk.

 

b.   You are the original purchaser of the equipment from a dealer and not an assignee or 

subsequent purchaser of the equipment.

 

Содержание CT Force Series

Страница 1: ...Pump installation and warranty guide for the CT range of pumps CT FORCE CT Xtra and CT Bathroom Models shown CT FORCE 15PT CT 50 Xtra CT 60BU Bathroom ISSUE E JAN 2017 Quality Technology Service Value...

Страница 2: ...you first rate advice regarding installation Consulting the helpline at the time of installation may entitle your customer to an additional 1 year FREE warranty cover UK Only for CT Xtra CT Bathroom...

Страница 3: ...ct description 4 Installation instructions 4 Step 1 Pump location 6 Step 2 Connecting the pump 10 Step 3 Electrical installation 11 PumpWise Guidelines 12 General specifications 17 Technical specifica...

Страница 4: ...ern to the cold water mains inlet Multiple cold water storage cisterns must be linked in accordance with current plumbing regulations and the bottom of the cisterns must be at the same level Hot water...

Страница 5: ...ature stated in the installation guide Never use mechanical tools to tighten plastic coupler nuts as this may cause damage and invalidate your warranty Never use jointing compounds Boss White Hemp or...

Страница 6: ...RCE 20 IPT 30 IPT CT Bathroom 60B 80B and CT Xtra 64H 69H 84H 94H are whole house pumps CT FORCE 15 TU 15 ITU 20 TU 20 ITU 20 SU 20 ISU 30 TU 30 ITU 30 SU 30 ISU CT Bathroom 60BU 80BU 90BU and CT Xtra...

Страница 7: ...sed A Salamander S flange or one of the 22mm approved top entry flanges see page 14 22mm No Stop Essex flange with 76mm dip pipe and birds beak cut end to limit air being drawn into the pump Indirect...

Страница 8: ...should be installed in accordance with BS7671 2008 it should also be noted that BS7671 2008 is a guide In BS7671 2008 rooms containing baths or showers should be broken down into zones These zones ar...

Страница 9: ...entry flange is fitted 13 If pump is fitted above cylinder a No Stop Essex flange must be used 14 Check that water storage capacity recovery meets required flow rates particularly at peak demand i e a...

Страница 10: ...uired Salamander s universal range of pumps activate the pump automatically even where no natural flow exists UK CT pumps suitable for negative head operation are CT FORCE 15 TU 20 TU 20 SU 30 TU and...

Страница 11: ...ng valves are open Fill system Check for leaks DO NOT RUN PUMP DRY to do so will cause irreparable damage to your pump and will invalidate your warranty Open shower mixer valve system outlets to maxim...

Страница 12: ...arter turn Mechanical tools must not be used to tighten plastic coupler nuts as this may cause damage which will invalidate the warranty B Hose to pump Do not twist or bend anti vibration hoses as thi...

Страница 13: ...facturer it s service agent or similarly qualified person in order to avoid a hazard All pipe work must be cross bonded in accordance with the IET Regulations The pump is supplied with a fuse fitted H...

Страница 14: ...to meet the increased demand of a pumped system a water starvation protection unit WSP may be considered See fig 11 The WSP is a Salamander level switch which must be positioned 102mm higher than the...

Страница 15: ...sal pump Horizontal cylinders As horizontal Torpedo cylinders are problematic for boosted systems consult PumpWise on 0191 516 2002 for guidance and correct use of an approved top entry flange S flang...

Страница 16: ...or two or more bathrooms the cold feed to the cylinder MUST be in 28mm pipework Water hammer protection Water hammer most commonly occurs in systems where there are long pipe runs supplying solenoid a...

Страница 17: ...mperature of the stored water should not normally exceed 60 C and in a combined central heating and domestic hot water system it is recommended that the stored water temperature is controlled independ...

Страница 18: ...ooster pumps in systems where the temperature of the stored hot water is uncontrolled see below Usable capacity minimum 50 galls per bathroom Vent and other services Salamander approved HWS TMV Blendi...

Страница 19: ...water supplies can cause the mechanical seal to stick if left for long periods without use The pump must be run at least five minutes every four weeks to exercise all working parts Connections BSP mal...

Страница 20: ...pplies can cause the mechanical seal to stick if left for long periods without use The pump must be run for at least five minutes every four weeks to exercise all working parts Connections BSP male In...

Страница 21: ...215 205 FORCE 20 PS FORCE 20 IPS 2 0 Bar Single End Positive Head Shower Pump 3 3A 3 130 1 3 170 1 7 200 2 0 22mm 21mm 3 4 22 190 120 165 5 27 295 215 205 FORCE 30 PS FORCE 30 IPS 3 0 Bar Single End P...

Страница 22: ...m 5 3 78 195 120 165 4 55 295 215 205 CT 75 Xtra 2 0 Bar Twin End Positive Head Shower Pump 3 3A 3 150 1 5 170 1 7 200 2 0 15mm 3 Inlet only 3 78 195 120 165 4 55 295 215 205 CT 79 Xtra 2 0 Bar Twin E...

Страница 23: ...Pump 3 3A 3 140 1 4 160 1 6 180 1 8 21mm 3 3 38 195 120 165 4 10 295 215 205 CT 94 H Xtra 2 6 Bar Single End House Pump 3A 200 2 0 240 2 4 260 2 6 21mm 5 22 225 120 165 6 06 295 215 205 CT Xtra CT Bat...

Страница 24: ...flow Ensure that all AV couplers are straight and not bent or distorted Air in system Run system on full hot with pump switched off i e gravity only for several minutes Check cold water storage is co...

Страница 25: ...e helpline 0191 516 2002 PumpWise from Salamander helps customers and provides a support service second to none Installers and customers can be sure of a speedy response to requests for technical help...

Страница 26: ...ng sensation brought to you by your Salamander Pump complete and return the attached Warranty card within 15 days of purchase take care that the temperature of your stored water NEVER exceeds the reco...

Страница 27: ...aced by a type not specified by the Company or if the equipment is incorrectly installed operated or used other than as described in the instruction manual or if any servicing or repair of the equipme...

Страница 28: ...ided the warranty card is completed and returned to the Company within 15 days of purchase iv Where the PumpWise helpline has been contacted and the recommendations implemented the warranty periods de...

Страница 29: ...le for equipment purchased and used exclusively in the UK and The Republic of Ireland only g Where the Company issues a replacement the equipment replaced shall be returned to the Company forthwith an...

Страница 30: ...28 Notes...

Страница 31: ...Freepost RLXE JHHY HLHJ Salamander Pumps Unit 2c Colima Avenue Sunderland SR5 3XE...

Страница 32: ...e hot water 8 Does the hot water cylinder have a flange fitted Yes n no n Surrey n Warix n No Stop Essex n 1st Tee on downward leg n 45 vent n 9 What size is the supply pipework to the pump 15mm n 22m...

Отзывы: