background image

INSTALLER'S AND OWNER'S MANUAL

5

Installer’s & Owner’s Manual

7. Maintenance

 CAUTION!

NOTE: Do not operate the unit without the proper filter or with 
a less effective filter. The heat exchange coils inside the unit 
could become clogged, resulting in a loss of effectiveness 
and/or efficiency and may require disassembly to clean.

7.1 Air Filter

SAKURA Dry-Boy ships with a standard MERV-11 65% 
1" pleated fabric filter and a 1/4" aluminum framed pre-filter 
installed. Operating the unit with a dirty or obstructed filter will 
reduce dehumidifier capacity and efficiency and may cause the 
compressor to cycle on and off unnecessarily.

7.2 Cleaning & Replacement

Check filters every six months. Clean and/or replace when filters are 
visibly dirty. See cleaning instructions below.

 

The 1/4" washable pre-filter 
should not to be discarded. 
Inspect the pre-filter for debris, 
dirt, or other obstructions at 
the same time the 1" pleated 
fabric filter is checked. Wash the 
1/4" pre-filter every time the 1" 
pleated fabric filter is replaced. To 
clean the 1/4" pre-filter, remove 
filter from the unit, rinse the 1/4" 
pre-filter in water with the water 
flowing through the aluminum 
support mesh side. Refer to 
Figure 11. Allow the filter to dry 
completely before reinstalling. 
Reinstall the filters per the 
instructions below or on the tag 
located on the 1/4" pre-filter.

 CAUTION!

NOTE: Failure to follow filter handling instructions may result 
in improper function of  the dehumidifier and cause premature 
filter wear.

7.3 Remove Filters

1.   Gently remove the 1/4" pre-filter by pulling on the tab 

attached to the filter.

2.    Gently remove the 1" pleated fabric filter by pulling it out 

of the unit.

7.4 Installing Filters

1.   Gently slide 1" pleated filter into filter slot. Do not force. 

If resistance is felt, check alignment for obstructions or 
debris inside the filter housing.

2.    Gently slide 1/4" pre-filter to left of 1" pleated filter. 

Do not force. If resistance is felt, check alignment for 
obstructions or debris inside the filter housing.

8. Service

 WARNING!

Servicing SAKURA Dry-Boy with its high pressure refrigerant 
system and high voltage circuitrypresents a health hazard which 
could result in death, serious bodily injury, and/or property 
damage. Only qualified service people should service this unit.

8.1 Technical Description

SAKURA Dry-Boy uses a refrigeration system similar to an air 
conditioner’s to remove heat and moisture from incoming air and 
add heat to the air that is discharged. Hot, high pressure refrigerant 

Figure 13: refrigeration system.

Figure 14: wiring diagram.

Содержание Dry-Boy SDB-45

Страница 1: ...SAKURA Basement Air System for Basement Crawlspace Dehumidification Installer s Owner s Manual High Efficiency Dehumidifier Dry Boy Model SDB 45 ...

Страница 2: ...btain maximum benefit from your SAKURA Dry Boy dehumidifier Read and Save These Instructions WARNING This symbol means important instructions Failure to heed them can result in serious injury or death CAUTION This symbol means important instructions Failure to heed them can result in injury or material property damage 1 Intended Application SAKURA Dry Boy is intended for installation in crawl spaces...

Страница 3: ... but should beinstalled directly in the area to be dehumidified Other considerations include 1 Providing access to a 115 VAC power outlet 10 power cord is provided 2 Locating near a floor or other suitable drain 8 drain hose included 3 Do not install SAKURA Dry Boy with the intake or exhaust of the unit within 1 of a wall or other obstruction Do not place the unit where curtains or debris can be dra...

Страница 4: ... RH drops 5 below the set point Approximate Humidity Levels Per Setting Dry 35 to 45 Relative Humidity Normal 45 to 55 Relative Humidity Recommended for most applications Humid 55 to 65 Relative Humidity The dehumidifier will run continuously until the relative humidity RH is reduced to the humidity control dial setting There is no benefit to setting the humidity control to dry in rooms under 65 doi...

Страница 5: ...efer to Figure 11 Allow the filter to dry completely before reinstalling Reinstall the filters per the instructions below or on the tag located on the 1 4 pre filter CAUTION NOTE Failure to follow filter handling instructions may result in improper function of the dehumidifier and cause premature filter wear 7 3 Remove Filters 1 Gently remove the 1 4 pre filter by pulling on the tab attached to the filter...

Страница 6: ...t breaker tripped 2 Humidity control set to Humid setting 3 Loose connection in internal wiring 4 Humidity control is defective No dehumidification Compressor does not run but blower runs with fan switch AUTO and humidity control turned to ON 1 Defrost thermostat open ambient temperature too low 2 Loose connection in compressor circuit 3 Defective compressor overload 4 Defective compressor or compr...

Страница 7: ... Remove middle top cover screw located on the drain port side Do not discard this screw It will be used to attach the mounting bracket in the next step Step 3 Align mounting bracket of condensate pump with the dehumidifier screw hole Reinstall screw that was removed in step 2 Step 4 Remove the 7 hose from the plastic bag and install this hose from the condensate pump onto the adaptor as indicated M...

Страница 8: ...8 Installer s Owner s Manual CONDENSATE PUMP INSTALLATION Step 5 Attach the 20 drain hose to the condensate pump and route it to a floor drain Plug in the condensate pump and the assembly is completed ...

Страница 9: ... metal plenum Lock the collar in position by bending the collar tabs outwards and flatten Step 4 All collar tabs are flattened Repeat steps 1 4 for top duct assembly Optional Accessory Duct Kit Duct Kit Assembly Instructions Do not drill any pilot holes into the plastic housing You may damage the internal components When installing screws be careful not to strip Lightly tighten screws ATTACHING COLL...

Страница 10: ...CT ASSEMBLY 1 Check sealing foam on the top duct assembly Ensure none has come loose 2 Place top duct assembly ensure the sealing foam makes contact around the plastic surfaces 3 Center the top duct assembly ensure the sealing foam makes contact around the plastic surfaces 4 Ensure the rear flange of the top duct assembly is seated flush against the back of the plastic housing See Figure 2 5 DO NOT ...