DUCT KIT ASSEMBLY
10
Installer’s & Owner’s Manual
FRONT DUCT ASSEMBLY
1. Check sealing foam on the front duct assembly. Ensure that
none has come loose.
2. Place front duct assembly on the intake side of the
dehumidifier.
3. Center the front duct assembly. Ensure the sealing foam makes
contact around the plastic intake grill surface. Sealing foam
should not cover any of the inlet portion of the intake grill.
4. DO NOT DRILL PILOT HOLES FOR SCREWS. You will risk
possibly damaging the internal components.
Using the
through holes provided in the top duct assembly, screw in the
four 10-16 X 1/2 screws directly into the plastic housing (see
Figure 1 — screws indicated in white circle). Be careful not to
strip loose. Lightly tighten screws. Do this in all four through
hole locations.
TOP DUCT ASSEMBLY
1. Check sealing foam on the top duct assembly. Ensure none has
come loose.
2. Place top duct assembly, ensure the sealing foam makes
contact around the plastic surfaces.
3. Center the top duct assembly, ensure the sealing foam makes
contact around the plastic surfaces.
4. Ensure the rear flange of the top duct assembly is seated flush
against the back of the plastic housing. See Figure 2.
5. DO NOT DRILL PILOT HOES FOR SCREWS. You will risk
possibly damaging the internal components.
Using the
through holes provided in the top duct assembly, secure back
flange of the top duct assembly first. Drive two 10-16 X 1/2
screws directly into the plastic housing. After the back flange
has been secured, drive in the last two screws (located on the
top) into the plastic housing using the same procedure.
6. Start unit and check for any air leaks around the perimeter of
the ducts.
7. If any leaks are found, seal leak with foil tape.
Duct Kit Assembly Instructions Continued
FIGURE 1