11-179
TROUBLESHOOTING
2-8-2. Continuous water spray works, but intermittent water spray does not operate 1/2
Water spray mode select switch must be “ ”.
Water spray timer switch must be “ I ”.
Set water spray pump switch to “PUMP 2”.
Reference Fig. : 2-8-1
Check point
Check/Cause
Action
1. Water Spray Timer
(1) when starter switch is ON and depress F-R lever water
spray switch once, measure voltage between water
spray timer terminal 1, 3 inlet wires G and chassis
ground.
Standard voltage : 12 V or more
(2) when starter switch is ON and depress F-R lever water
spray switch once, measure voltage between water
spray timer terminal 4 outlet wire GB and chassis
ground.
Standard voltage : 12 V or more
If above item (1) is OK and item (2) is NG with no
abnormality found in grounding of water spray timer, water
spray timer is faulty.
•
Replace water spray
timer.
2. Water Spray Timer
Switch
(1) when starter switch is ON and depress F-R lever water
spray switch once, measure voltage between water
spray timer switch terminal 2 inlet wire GL and chassis
ground.
Standard voltage : 12 V or more
(2) when starter switch is ON and depress F-R lever water
spray switch once, measure voltage between water
spray timer switch terminal 3 outlet wire G and chassis
ground.
Standard voltage : 12 V or more
If above item (1) is OK and item (2) is NG, water spray
timer switch is faulty.
•
Replace water spray
timer switch.
3. water Spray Pump
(F, 2)
(1) when starter switch is ON and depress F-R lever water
spray switch once, measure voltage between water
spray pump relay (F, 2) terminal 1 inlet wire G and
chassis ground.
Standard voltage : 12 V or more
(2) when starter switch is ON and depress F-R lever water
spray switch once, measure voltage between water
spray pump relay (F, 2) terminal 5 inlet wire Lw and
chassis ground.
Standard voltage : 12 V or more
(3) when starter switch is ON and depress F-R lever water
spray switch once, measure voltage between water
spray pump relay (F, 2) terminal 3 outlet wire Gw and
chassis ground.
Standard voltage : 12 V or more
If above items (1) and (2) are OK and item (3) is NG,
water spray pump (F, 2) is faulty.
•
Replace water spray
pump (F, 2).
•
•
•
Содержание SW880-1
Страница 1: ...SW880 1 990 1 SHOP MANUAL 3498 6568A 0 ...
Страница 2: ......
Страница 4: ......
Страница 14: ......
Страница 15: ...SAFETY ...
Страница 16: ......
Страница 24: ......
Страница 25: ...SPECIFICATIONS ...
Страница 26: ......
Страница 27: ......
Страница 31: ......
Страница 39: ...ENGINE AND CONTROLS ...
Страница 40: ......
Страница 46: ......
Страница 47: ...HYDRAULIC SYSTEMS ...
Страница 48: ......
Страница 49: ......
Страница 52: ......
Страница 54: ......
Страница 56: ......
Страница 58: ......
Страница 59: ......
Страница 68: ......
Страница 70: ......
Страница 72: ......
Страница 76: ......
Страница 78: ......
Страница 82: ......
Страница 83: ...ELECTRICAL SYSTEM ...
Страница 84: ......
Страница 88: ......
Страница 90: ......
Страница 92: ......
Страница 94: ......
Страница 125: ...VIBRATORY DRUM ...
Страница 126: ......
Страница 136: ......
Страница 171: ...BRAKE ...
Страница 172: ......
Страница 175: ...OPERATOR STATION ...
Страница 176: ......
Страница 179: ...WATER SPRAY SYSTEM ...
Страница 180: ......
Страница 182: ......
Страница 183: ...INSPECTION AND ADJUSTMENT ...
Страница 184: ......
Страница 209: ...TROUBLESHOOTING ...
Страница 210: ......
Страница 427: ......