10-041
TROUBLESHOOTING
2-6-1. Head lamp, side marker lamp, tail lamp and license lamp do not light 2/2
Reference Fig.: 2-6-1
Check point
Check/Cause
Action
5. Lighting LO/HI Relay
(1) when starter switch is ON, lighting switch is “
” and
turn signal switch is “Low-beam”, measure voltage
between lighting LO/HI relay terminal a inlet wire Rw
and chassis ground.
There is no electricity in normal condition.
(2) when starter switch is ON and lighting switch is “
”,
measure voltage between lighting LO/HI relay terminal c
inlet wire RY and chassis ground.
Standard voltage : 12 V or more
(3) when starter switch is ON, lighting switch is “
” and
turn signal switch is “Low-beam”, measure voltage
between lighting LO/HI relay terminal f outlet wire RB
and chassis ground.
Standard voltage : 12 V or more
If above items (1) and (2) are OK and item (3) is NG,
lighting LO/HI relay is faulty.
•
Replace lighting LO/HI
relay.
6. Harness Connecting
Between Terminals
Measure resistance of harness connecting between
terminals.
Standard resistance : 10 Ω or less
If resistance is abnormal, harness is faulty.
•
•
Repair or replace
harness.
2-6-2. Flood lamp does not light 1/2
Reference Fig.: 2-6-1
Check point
Check/Cause
Action
1. Each Bulb
Check that none of lamp bulbs is burned out or has a
contact failure.
Bulb is faulty or poorly connected.
•
•
Replace each bulb.
2. Flood Lamp Switch
(1) when starter switch is ON, measure voltage between
flood lamp switch terminal 1 inlet wire GR and chassis
ground.
Standard voltage : 12 V or more
(2) when starter switch is ON and flood lamp switch is ON,
measure voltage between flood lamp switch terminal 2
outlet wire Sb and chassis ground.
Standard voltage : 12 V or more
If above item (1) is OK and item (2) is NG, flood lamp
switch is faulty.
•
Replace flood lamp
switch.
3. Flood Lamp Relay
(1) when starter switch is ON and flood lamp switch is ON,
measure voltage between flood lamp relay terminal 1
inlet wire Sb and chassis ground.
Standard voltage : 12 V or more
(2) when starter switch is ON and flood lamp switch is ON,
measure voltage between flood lamp relay terminal 3
inlet wire GR and chassis ground.
Standard voltage : 12 V or more
(3) when starter switch is ON and flood lamp switch is ON,
measure voltage between flood lamp relay terminal 5
outlet wire RG and chassis ground.
Standard voltage : 12 V or more
If above items (1) and (2) are OK and item (3) is NG, flood
lamp relay is faulty.
•
Replace flood lamp relay.
Содержание R2-4
Страница 1: ...R2 4 SHOP MANUAL 3498 6634A 0...
Страница 2: ......
Страница 4: ......
Страница 12: ......
Страница 13: ...SAFETY...
Страница 14: ......
Страница 22: ......
Страница 23: ...SPECIFICATIONS...
Страница 24: ......
Страница 25: ......
Страница 42: ......
Страница 43: ...ENGINE AND CONTROLS...
Страница 44: ......
Страница 51: ...HYDRAULIC SYSTEMS...
Страница 52: ......
Страница 53: ......
Страница 56: ......
Страница 58: ......
Страница 60: ......
Страница 62: ......
Страница 64: ......
Страница 66: ......
Страница 67: ......
Страница 78: ......
Страница 82: ......
Страница 83: ...ELECTRICAL SYSTEM...
Страница 84: ......
Страница 88: ......
Страница 90: ......
Страница 120: ......
Страница 121: ...DRUM...
Страница 122: ......
Страница 129: ...BRAKE...
Страница 130: ......
Страница 132: ......
Страница 134: ......
Страница 135: ...WATER SPRAY SYSTEM...
Страница 136: ......
Страница 138: ......
Страница 139: ...INSPECTION AND ADJUSTMENT...
Страница 140: ......
Страница 159: ...TROUBLESHOOTING...
Страница 160: ......
Страница 233: ......