VERS. 2017.06.21
CM 501 ME_MAN_EN
11
Electrical Motor and switch (10)
Motor: Low voltage trigger (NVR) built in the switch prevents the motor to restart for example after a
power cut.
The electric motor has an overload protection. Thermal overload tripping can occur for two reasons:
a. tripping under light load
If connection is incorrect
b. tripping under heavy load
If motor has been overloaded
2.4 Technical Data
MODELS
Motor
2,2kW 115V 1 phase NVR 50Hz
3000min
-1
70184628235
2,2kW 230V 1 phase NVR 50Hz
3000min
-1
70184628236
3kW 400V 3 phases NVR 50Hz
3000min
-1
70184628230
3kW dual tension 230V/400V 3
phases NVR 50Hz 3000min
-1
70184628234
4kW dual tension 230V/400V 3
phases NVR 50Hz 3000min
-1
70184628233
4kW 400V 3 phases NVR 50Hz
3000min
-1
70184627018
70184628232
4kW 525V 3 phases NVR 50Hz
3000min
-1
70184628238
Electric motor protection
IP54
Max. blade diameter
350mm
70184628234
70184628230
500mm
70184627018
70184628233
70184628235
70184628236
70184628238
600mm
70184628232
Bore
25,4mm
Blade shaft speed
2700 min
-1
70184628234
70184628230
1900 min
-1
70184627018
70184628233
70184628235
70184628236
70184628238
70184628232
Содержание NORTON CLIPPER CM 501 ME
Страница 1: ...CM 501 ME OPERATING INSTRUCTIONS Translation of the original instructions...
Страница 2: ...VERS 2017 06 21 CM 501 ME_MAN_EN 2...
Страница 4: ...VERS 2017 06 21 CM 501 ME_MAN_EN 4...
Страница 23: ...VERS 2017 06 21 CM 501 ME_MAN_EN 23 7 3 CIRCUIT DIAGRAM 230V Motor...
Страница 24: ...VERS 2017 06 21 CM 501 ME_MAN_EN 24 115V Motor...
Страница 25: ...VERS 2017 06 21 CM 501 ME_MAN_EN 25 400V Motor CM 501 4kW 5 3 A CM 501 3 kW 4 1 A...
Страница 26: ...VERS 2017 06 21 CM 501 ME_MAN_EN 26 230V 400V dual tension motor CM 501 4kW 5 3 A CM 501 3 kW 4 1 A...