  Chemical  reactions  in  the  product  chamber  of  the  pump  (mixture  of  different  substances)  and  the 
freezing of the liquid have to be avoided.  
 
 Before putting the pump back into operation, the tightness of the pump has to be checked.  
 
 
  The  operation  of  the  pump  with  nitrogen  as  driving  gas  is  possible.  In  closed  rooms  sufficient 
ventilation must be provided.  
 
 Procedure for pump return: every unit which is send to SGPPL  has to be accompanied by a RGA 
(return goods authorization) sheet. Otherwise a processing is not possible. Please contact SGPPL or 
local distributor to get the RGA file.  

All pumps returned to SGPPL must be decontaminated

 

 

 

When the pump is handling liquids higher than 122°F (50°C), avoid direct contact with 

the  pump  or  piping  system.  Use  appropriate  hand  protection  if  handling  of the  pump  or 
piping is necessary. 
 

 

Always  wear  protective  gear  (goggles,  face  shield,  acid  resistant  gloves,  etc.),  when 

removing or servicing the pump. In addition, flush the pump completely with di water prior 
to any service or maintenance. 
 

Ensure suction or discharge line valves are fully opened during pump operation

. Never 

Close a suction or discharge line valve during operation. 
 

 

Any fluctuation in supply air pressure or volume causes a change in pump discharge. 

Install a regulating valve to stabilize supply air pressure.  
 

When  pumping  a  hazardous  liquid,  ventilating  the  cabinet  is  advised  to  remove  toxic 

gas which may permeate components and build up inside the equipment. 
 
 
 

Содержание MDP 50

Страница 1: ...INPERFORMANCE SAINT GOBAINPERFORMANCEPLASTICS PLASTICS FRANCE EADAC DES BERTHILLIERS 7301 Orangewood Avenue F 71850 CHARNAY LES MACON Garden Grove CA 92841 Tel 33 0 3 85 20 27 00 Tel 1 714 630 5818 Fax 33 0 3 85 29 18 48 Fax 1 714 688 2614 www microelectronics saint gobain com ...

Страница 2: ...III 1 Testing III 2 Set up III 3 Connections III 3 1 Air nitrogen connections III 3 2 Fluid connections III 4 Initial tests and adjustments IV Applications 3 IV 1 Chemical compatibility IV 2 Temperature range IV 3 Cleaning IV 4 Single stroke adjustment IV 5 Limitations of use V Trouble shooting 5 VI Warranty safety 5 Appendix 7 Section view Dimensions Pneumatic wiring diagram ...

Страница 3: ...he top of the pump The pump speed varies with operating conditions air pressure viscosity density I 4 Pump data The main characteristics of the MPD 50 pump are Repeatability 1 Dispense volume per shot 0 to 0 5 mL Dispense speed 0 to 0 5 mL s max Delivery pressure 4 3 psig 0 3 bar max at 70 psig 4 8 bar air actuation Air nitrogen pressure 50 70 psig 3 4 4 8 bar Suction height 2 feet 0 6m based on w...

Страница 4: ...l valve is to control the speed of the suction cycle The integrated check valve is for a quick release of the pressure during the discharge cycle 3 2 way valve is necessary for the on off cycle of the pump When the 3 2 valve is actuated it is the suction cycle When the 3 2 valve is not actuated it is the discharge cycle Pressure regulator is to setup the right pressure Filter If the air nitrogen o...

Страница 5: ...ge line It is recommended to adjust the stem to the maximum stroke 3 Check the delivered volume of liquid with a calibrated beaker test tube or a precision balance to calculate the single stroke 4 If unit stroke is not as required screw on the adjustable stem to reduce the stroke or unscrew it to increase the volume 5 Repeat the stroke until you get the required volume of liquid per shot 6 When th...

Страница 6: ...e year from delivery date SGPPL is not responsible for damage to its products through improper installation maintenance use or attempts to operate them beyond their mechanical capability intentionally or otherwise or for unauthorized repair SGPPL shall not be liable for any indirect special incidental or consequential damages resulting from the use failure or malfunction of any product Safety hint...

Страница 7: ...ted When the pump is handling liquids higher than 122 F 50 C avoid direct contact with the pump or piping system Use appropriate hand protection if handling of the pump or piping is necessary Always wear protective gear goggles face shield acid resistant gloves etc when removing or servicing the pump In addition flush the pump completely with di water prior to any service or maintenance Ensure suc...

Страница 8: ...7 7 ...

Отзывы: