IV – Applications 

 

IV.1 – Chemical compatibility 

 
Wetted  parts  are  manufactured  from  PTFE  and  PFA  and  are  suitable  for  pumping  even  the  most 
corrosive concentrated chemicals: H

2

SO

4

, HNO

3

, HF, H

3

PO

4

, HCl, NH

4

OH, KOH, NaOH, CH

3

COOH, 

TMAH, H

2

O

2

...  

The viscosity of the liquids must be less 50 cPo 
Very abrasive liquids and liquids that crystallize, are not recommended. 
Please call SGPPL if you require information on chemical compatibility. 
 

IV.2 – Temperature range 

 
The pump can handle liquids from 41 °F to 180 °F (5 °C  to 82 °C). 
When the fluid temperature is greater than 140 °F (60 

°

C) you must check from time to time that the 

delivery/suction manifold nuts are fully tight. 
 
For special applications call SGPPL or your local distributor. 
 

IV.3 – Cleaning 

 
The plastic design of the MDP 50 pump wetted parts allows the use of any cleaning materials. 
 
When flushing the pump, it is better to adjust it for maximum flow per stroke. 
 

IV.4 – Single stroke adjustment 

 
To adjust the stroke, please proceed as follows: 
1)  Check fluid connections, 
2)  Prime  the  pumps  until  the  fluid  line  is  full  (no  more  air  bubbles  visible  in  suction  and  discharge 

line). It is recommended to adjust the stem to the maximum stroke. 

3)  Check the delivered volume of liquid with a calibrated beaker, test tube or a precision balance to 

calculate the single stroke. 

4)  If unit stroke is not as required, screw on the adjustable stem to reduce the stroke, or unscrew it to 

increase the volume. 

5)  Repeat the stroke until you get the required volume of liquid per shot. 
6)  When the adjustment is achieved lock the position of the adjustable stem with the lock nut. 
 
Now, your pump is ready to run. 
 
 

CAUTION

:  if  you  modify  air  pressure  and/or  air  flow  rate  after  adjustment,  this  will  affect  the  stroke 

volume. 
 
Once you have reached the required stroke, the stroke volume is repeatable to +/- 1%. 
Nevertheless,  we  recommend  checking  the  stroke  volume  regularly,  especially  if  external  conditions 
are varying (backpressure, suction head, temperature, fluid...) 
 

IV.5 – Limitations of use 

 

To obtain the best results from your pump, you should not: 

 

Operate the pump outside pressure ranges 

 

Restrict suction side (valves, filters...), 

 

Connect the pump inlet with liquid under pressure, 

 

Exceed the maximum or minimum temperature limits, 

 

Pump too viscous or abrasive liquids, 

 

Try to adjust the unit stroke beyond the specified range  

 

Exceed the pumping speed  

 

Forget to respect connection specifications (see encl. diagrams). 

Содержание MDP 50

Страница 1: ...INPERFORMANCE SAINT GOBAINPERFORMANCEPLASTICS PLASTICS FRANCE EADAC DES BERTHILLIERS 7301 Orangewood Avenue F 71850 CHARNAY LES MACON Garden Grove CA 92841 Tel 33 0 3 85 20 27 00 Tel 1 714 630 5818 Fax 33 0 3 85 29 18 48 Fax 1 714 688 2614 www microelectronics saint gobain com ...

Страница 2: ...III 1 Testing III 2 Set up III 3 Connections III 3 1 Air nitrogen connections III 3 2 Fluid connections III 4 Initial tests and adjustments IV Applications 3 IV 1 Chemical compatibility IV 2 Temperature range IV 3 Cleaning IV 4 Single stroke adjustment IV 5 Limitations of use V Trouble shooting 5 VI Warranty safety 5 Appendix 7 Section view Dimensions Pneumatic wiring diagram ...

Страница 3: ...he top of the pump The pump speed varies with operating conditions air pressure viscosity density I 4 Pump data The main characteristics of the MPD 50 pump are Repeatability 1 Dispense volume per shot 0 to 0 5 mL Dispense speed 0 to 0 5 mL s max Delivery pressure 4 3 psig 0 3 bar max at 70 psig 4 8 bar air actuation Air nitrogen pressure 50 70 psig 3 4 4 8 bar Suction height 2 feet 0 6m based on w...

Страница 4: ...l valve is to control the speed of the suction cycle The integrated check valve is for a quick release of the pressure during the discharge cycle 3 2 way valve is necessary for the on off cycle of the pump When the 3 2 valve is actuated it is the suction cycle When the 3 2 valve is not actuated it is the discharge cycle Pressure regulator is to setup the right pressure Filter If the air nitrogen o...

Страница 5: ...ge line It is recommended to adjust the stem to the maximum stroke 3 Check the delivered volume of liquid with a calibrated beaker test tube or a precision balance to calculate the single stroke 4 If unit stroke is not as required screw on the adjustable stem to reduce the stroke or unscrew it to increase the volume 5 Repeat the stroke until you get the required volume of liquid per shot 6 When th...

Страница 6: ...e year from delivery date SGPPL is not responsible for damage to its products through improper installation maintenance use or attempts to operate them beyond their mechanical capability intentionally or otherwise or for unauthorized repair SGPPL shall not be liable for any indirect special incidental or consequential damages resulting from the use failure or malfunction of any product Safety hint...

Страница 7: ...ted When the pump is handling liquids higher than 122 F 50 C avoid direct contact with the pump or piping system Use appropriate hand protection if handling of the pump or piping is necessary Always wear protective gear goggles face shield acid resistant gloves etc when removing or servicing the pump In addition flush the pump completely with di water prior to any service or maintenance Ensure suc...

Страница 8: ...7 7 ...

Отзывы: