A2CH3 F16 – OPERATING INSTRUCTIONS
INDEX DATE N°
00 06/02/09
DC69020
10/16
Possible cause
How to check
Solution
Loose tubing, or hole in tubing
upstream of the pump
Replace inlet tubing with testing
tube running directly from inlet on
the pump to the tank, and see if
normal operation resumes
Replace defective tubing
Damaged bellows
Check to see if mist or dripping is
coming from the muffler or from
the PP core
Return the pump to SGPPL
FRANCE, site of Charnay
Liquid is dripping from the pump
Possible cause
How to check
Solution
Manifold nut improperly/not
enough tightened
Check if manifold nuts are
properly tightened
Check that thread is not damaged.
Retighten manifold nuts
Connection nut improperly/not
enough tightened
Check if connection nuts are
properly tightened
Check that thread is not damaged.
Retighten connection nuts
Internal pump failure
Replace the pump with a new
pump (same model) and see if
normal operation resumes
Return the pump to SGPPL
FRANCE, site of Charnay
Damaged bellows
Check to see if mist or dripping is
coming from the muffler or PP
core
Return the pump to SGPPL
FRANCE, site of Charnay
VIII – Warranty
Our pumps and accessories are warranted for all parts and labor against faulty workmanship (return
to factory) for 2 years from delivery date.
During the 6 following years, this warranty period of 2 years can be renewed if the maintenance of the
pump is made using our PM kit and following the instructions included in "A2CH3 F16 –
MAINTENANCE AND REPAIR PROCEDURES".
SGPPL FRANCE is not responsible for damage to its products through improper installation,
maintenance, use or attempts to operate them beyond their mechanical capacity, intentionally or
otherwise, or for unauthorized repair.
SGPPL FRANCE shall not be liable for any indirect, special, incidental or consequential
damages resulting from the use, failure or malfunction of any product.
® Teflon Du Pont's registered trademarks
Содержание AstiPure II series
Страница 13: ...A2CH3 F16 APPENDIX SECTION VIEW OF THE PUMP INDEX DATE N 00 06 02 09 DC69020 12 16...
Страница 14: ...A2CH3 F16 APPENDIX SECTION VIEW OF THE SHUTTLE VALVE INDEX DATE N 00 06 02 09 DC69020 13 16...
Страница 16: ...A2CH3 F16 APPENDIX PUMP SIZES INDEX DATE N 00 06 02 09 DC69020 15 16 PART NUMBER INDEX A2XX3 00...