Страница 1: ...USER INSTALLATION MANUAL SAILOR H4122 Iridium Ship Security Alert System ...

Страница 2: ... relying on this information should satisfy himself herself as to the most current version Providers with access to Thrane Thrane s Extranet may obtain current copies of manuals at http extranet thrane com Thrane Thrane is not responsible for the content or accuracy of any translations or reproductions in whole or in part of this manual from any other source Law requirement In the requirements for...

Страница 3: ...em Contents Introduction ii About this Manual ii Abbreviations 1 System Overview 2 Operating How to use the SSAS 3 Normal mode 3 Alert mode 3 Test mode 4 Iridium Tracking System 5 Connecting a PC 5 Installation 6 Technical Specification 6 System Block Diagram 8 Interfaces 9 Cable Connection Diagram 10 Connection Scheme for push Terminals 11 Cable Dimensions 11 Software Settings 11 Status and Messa...

Страница 4: ...incoming alert resets Download new software to the Iridium SSAS Box Download new HTML pages for the configuration In case a ship is being attacked by pirates or terrorists the crew needs a possibility to send a silent alert message to a predefined alert centre It should be possible to activate the alert via an alert button from the navigation bridge and in at least one other location Via the alert...

Страница 5: ...dically until they are reset The time between the messages can be set from 1x5 minutes to 255x5 minutes The setting is made at the configuration page The message will be sent to all the predefined recipients listed in the configuration When an alert message is sent the SMS messages stored on the SIM card will be deleted in order to make room for receiving an alert reset SMS Notice It is possible t...

Страница 6: ...he alert message Test mode The test mode is used to check that the system is working properly The test message will contain the same information as the alert message table 1 The only difference is the message code TESTALERT at the beginning of the messages Test messages will be send only to the recipients listed in the configuration setup page TESTALERT MESSAGE_NUMBER SHIPNAME MMSI_number IMO_numb...

Страница 7: ...e entered at the configuration page It is possible to send both to an Iridium telephone number and to an Email address Notice The ITS message will be send only to the recipient listed in the configuration page It will not reply to the sender if this is different from the listed recipients Connecting a PC When the Iridium SSAS Box is in normal mode the data interface of the Iridium transceiver can ...

Страница 8: ...83 version 2 20 and 2 30 Following NMEA messages are supported GPRMC GPGLL GPVTG and GPZDA Check sum is recommended LAN Ethernet TCP IP 10 100Mbps IP Class IP22 Compass safe distance 80cm IMPORTANT The power supply for the Iridium transceiver and the Iridium SSAS Box must have a backup power in case of power failure on the ship s AC supply This is a requirement specified by the IMO resolution MSC ...

Страница 9: ... 49 Mounting 39286 Free space for mounting Free space for cable entry 50 50 min 100 50 Iridium SSAS Alert Button Box SSAS Test Button Box 91 91 28 19 5 52 60 15 5 37 23 5 12 5 3 pcs ø4 50 39283 DRILLING PLAN Cable entry Cable entry Weight SSAS Box 1 7 kg SSAS Alert Button Box SSAS Test Button Box 0 3 kg 0410 ...

Страница 10: ...Alert Button Box L1 Cable length max 50m Option B L1 L2 50 metres Power Supply L2 Option Option A Alert Button Box L2 Alert Button Box Alert Button Box Alert Button Box NB Option A or option B only allowed PC Option GPS Input Power supply PC Interface 0415 The system is made for 2 alert buttons but can handle 2 additional alert buttons by connecting them as option A or option B The GPS input can b...

Страница 11: ...Pin Name Function Specification 1 CNT Contact 5V DC logical input internal pull up 2 LED Light LED current max 30mA 3 REF Reference Power supply Connector type 3 pole push connector Pin Name Function Specification 1 BAT Positive power line Voltage 10 32 VDC Current max 300mA 2 BAT Negative power line 3 BAT Negative power line Iridium interface data Connector type 9 pin Sub D Male Data Out Pin Name...

Страница 12: ...X12 DC DC DC NMEA NMEA REF CNT LED REF CNT LED REF CNT LED REF U7 X1 X2 24V DC Power In GPS Input Alert Button Box 1 REF F1 Fuse 1AF Status Indicator Iridium Interface PC Interface LED CNT Alert Button Box 2 Test Button Box CNT LED REF CNT LED REF 0435 ...

Страница 13: ...ress you must make sure to write down the new addresses on the IP Address Label The IP address can be set back to default by switching off the power from the Iridium SSAS Box and pressing down the test button when power is switched on again The Test button terminal on the board can be short circuited during power up Connecting a PC to the LAN Using a cross cable HUB or switch The network settings ...

Страница 14: ...layed Enter the IP address subnet mask according to the figure above and click OK to save the new IP address specification To get in contact with the web pages on the Iridium SSAS Box any Internet explorer program can be used Write the address for the Iridium SSAS Box in the search field http 192 168 2 40 and press Enter or Search Now the Index page of the Iridium SSAS Box is shown If not then che...

Страница 15: ...hich Test messages should be sent ON OFF ON Whether or not the light pulses in the alarm button should be shown OFF NORMAL INVERTED NORMAL Configuration of the light in the test button 1 255 5 minutes 3 How often should the Alarm SMS be sent 1 6 5 minutes Max 30 minutes 1 How often should the Test Alarm SMS be sent Max 8 digits Password which should be included in the Alarm reset messages Max 8 di...

Страница 16: ... Step 1 Connect the Ethernet LAN cable to the RJ45 connector on the Iridium SSAS Box Step 2 Set up the configuration table in the Iridium SSAS Box to have only one recipient Type the Email address in the field Alarm Email address 1 Press the button configure SSAS Step 3 Press the first alert activation button for minimum 2 seconds Check that the light in the test button turns on or off according t...

Страница 17: ...dicate that there is no contact to the Iridium transceiver The alert mode cannot be deactivated The service centre number may be wrong for which reason the Iridium transceiver cannot be initialised Make a factory reset It is not possible to get in contact with the Iridium SSAS Box via the LAN interface The IP address is forgotten Make a factory reset IP address is now 192 168 2 40 Test mode will n...

Страница 18: ......

Страница 19: ... for connection to PC 56 171 Optional H4125 Iridium SSAS Alert Button Box 8041250206 H4126 Iridium SSAS Test Button Box 8041260206 SAILOR N163S AC DC Power Supply Blackgrey 80119410 Acessories ATO Blade Fuse 1AF 45 657 Cable for buttons 2 x 2 x 0 5mm2 twisted pair with shield specify length when ordering 77 176 0424 ...