SAH WSK Series Скачать руководство пользователя страница 3

1. Temperature and humidity controller uses  a dedicated microprocessor, SMT
 SMT technology and high precision temperature and humidity sensor. Make
 the product delicate and cabinet, reliable performance, high precision 
measurement and control temperature and humidity, strong anti-jamming 
capability control mode is simple. Can be widely used in industry, agriculture, 
medical, chemical warehouse where the temperature and humidity 
measurement and control.
2. Alarm function, this controller has the temperature, humidity process heater
 disconnection quotation function, communication function, get more extensive
 application in the field of automation control

   

Remark: 

  Process alarm output contact and disconnection alarm for the same.

INTRODUCTION

Main Technical Data

Supply voltage

AC: Switching power supply 85V~265V, 50~60Hz
AC: Transformer 

110V,  220V,  380V,  50~60Hz

DC: 24V, 36V, 48V, 110V, 220V

Accuracy class

 

Temperature: ±0

.

5°C

Humidity: 5%±RH
Resolving power: 14 Bit
Cycle of sampling: 0.5 Sec

Measurement range

Temperature: -40~100°C
Humidity: 0~100

%

RH

Display

Measured values and set values by LED
Output condition and alarming condition by LED lights

Way of operating

Controlling by two-step (settable turn difference)

Control output

Relay output: Contact capability 250VAC 3A (Resistive load)
Voltage pulse output: 0~12 (Suitable for solid relay SSR)

Output contact

Electrical endurance: 1×10

 

times

Mechanical durability: 1×10

 

times

Installation

Panel type and embedded

Others

Insulation resistance: 

50MΩ (500VDC)

Insulation capability: 1500VAC per minute
Power consumption: 

10VA

Environment: 0~50°C, 30~85%RH no corrosive gas
Weight: About 0.5Kg (The power supply of product is the 
switching power supply)

WSK INTELLIGENT TEMPERATURE AND HUMIDITY CONTROLLER

WSK INTELLIGENT TEMPERATURE AND HUMIDITY CONTROLLER

Содержание WSK Series

Страница 1: ...WSK INTELLIGENT TEMPERATUREAND HUMIDITY CONTROLLER USER MANUAL ...

Страница 2: ...n to prevent the power cord and input output strong current shock 2 Power supply In order to prevent the equipment damage or failure please use the rated power To prevent electric shock or equipment failure all wiring complete rear can supply 3 Prohibited to use in the vicinity of flammable gas As fire explosion or equipment damage banned in flammable explosive gas venting occasion use 4 It is for...

Страница 3: ...er supply 85V 265V 50 60Hz AC Transformer 110V 220V 380V 50 60Hz DC 24V 36V 48V 110V 220V Accuracy class Temperature 0 5 C Humidity 5 RH Resolving power 14 Bit Cycle of sampling 0 5 Sec Measurement range Temperature 40 100 C Humidity 0 100 RH Display Measured values and set values by LED Output condition and alarming condition by LED lights Way of operating Controlling by two step settable turn di...

Страница 4: ... TEMPERATU RE AND HUMIDITY CONTROLLER WSK INTELLIGENT TEMPERATU RE AND HUMIDITY CONTROLLER WSK INTELLIGENT TEMPERATU RE AND HUMIDITY CONTROLLER WSK INTELLIGENT TEMPERATURE AND HUMIDITY CONTROLLER WSK INTELLIGENT TEMPERATURE AND HUMIDITY CONTROLLER The wiring diagram subject to the product itself the wiring diagram 485 Frame Size Hole Size Frame Size and Hole Size Frame Size and Installation Hole S...

Страница 5: ...indicator lights The communications light Instrument power light work Increasing Key Decreasing Key Up Key Down Key Displacement Key Mode Key Confirm Key Quit Key Operation Process Boot Up Process Open the Power Self checking of LED device Automatic Automatic Transfomation Transfomation Displaying the current temperature and humidity All LEDS light up Measuring the current temperature and humidity...

Страница 6: ...s the master slave communication response mode connections on a communication line First of all the main computer of the signal only address addressing to a terminal equipment machine and then the response signal from the terminal to transmit to host in the opposite direction i e in a single communication line signal transmission instead of two direction all communication data flow half duplex wor...

Страница 7: ...he address of the query When the terminal sends back a response in the response from the machine address data and tell the host which terminal is to communicate with them ONE ONE ONE ONE TWO TWO CODE Meaning Behavior Function Code Table 2 Tell what is addressing to the terminal to perform the function Listed in the following table shows the supported code function and their meaning and function Ta...

Страница 8: ...ng setting Temperature heater disconnection alarming setting Temperature process alarming setting Humidity process alarming setting Humidity process alarming state Temperature process alarming state ON ON ON ON OFF OFF OFF OFF OFF Lower deviation alarming Lower deviation alarming Higher deviation alarming Higher deviation alarming 3 is the highest brightness the lED display brightness the controll...

Отзывы: