WSK INTELLIGENT TEMPERATURE AND HUMIDITY CONTROLLER

WSK INTELLIGENT TEMPERATURE AND HUMIDITY CONTROLLER

USER MANUAL v 1.0

      Thanks for choosing the Intelligent temperature and humidity controller 
  of our company. In order to convenient you to buy and use the controller 
with safety, please read this manual carefully and note the following points.

CAUTION

1. The device must be installed and maintained by professional personnel

2. 

The signal and power supply must be cut off before any operations to the 

       internal or external part of the controller

The following conditions will cause damage or abnormality to the controller
  

1. Auxiliary power source voltage over range

  2. Distribute system frequence over range
  3. Current, voltage input poles incorrect
  4. With electric pull out communication plug
  5. No according requirement to connect termin

al

Warning

1. Wiring warning
    If the equipment failure or error occurs, can cause system fault, installation 
  of external protection circuit to prevent such incidents
    In order to prevent the equipment damage or failure, choose the appropriate 
 fuse protection to prevent the power cord and input, output, strong current  shock
2. Power supply
    In order to prevent the equipment damage or failure, please use the rated 
power
    To prevent electric shock, or equipment failure, all wiring complete rear can
 supply
3. Prohibited to use in the vicinity of flammable gas
    As fire, explosion or equipment damage, banned in flammable, explosive 
 gas, venting occasion use
4. It is forbidden to touch the instrument inside
    To prevent electric shock or burn, it is forbidden to touch the instrument 
inside, only the company service engineer can check the internal wiring or 
replacement parts. Instrument with
    high pressure and high temperature parts. Very dangerous.
5. It is forbidden to change instrument
    In order to prevent accidents or equipment failure, it is forbidden to change 
equipment
6. Maintenance
    Scrapped to prevent electric shock, instrument or fails, only the company's 
service engineer can be replacement parts
    In order to ensure the instrument is continuous and safe use, should be 
 regular maintenance.  Instrument internal some parts may be damaged with
 longer duration of use

CATALOG

1. Introduction

…………………………

2

.

Technical

 

Data

………………………………

2

3.Definition and Specification Matching

………

3

4. Outline

、 

installation hole and wiring

………

4

5

.

PanelExplain and Each function

………………

5

6. Operation Process

…………………………

6

-

12

………

1

    
 

Содержание WSK Series

Страница 1: ...WSK INTELLIGENT TEMPERATUREAND HUMIDITY CONTROLLER USER MANUAL ...

Страница 2: ...n to prevent the power cord and input output strong current shock 2 Power supply In order to prevent the equipment damage or failure please use the rated power To prevent electric shock or equipment failure all wiring complete rear can supply 3 Prohibited to use in the vicinity of flammable gas As fire explosion or equipment damage banned in flammable explosive gas venting occasion use 4 It is for...

Страница 3: ...er supply 85V 265V 50 60Hz AC Transformer 110V 220V 380V 50 60Hz DC 24V 36V 48V 110V 220V Accuracy class Temperature 0 5 C Humidity 5 RH Resolving power 14 Bit Cycle of sampling 0 5 Sec Measurement range Temperature 40 100 C Humidity 0 100 RH Display Measured values and set values by LED Output condition and alarming condition by LED lights Way of operating Controlling by two step settable turn di...

Страница 4: ... TEMPERATU RE AND HUMIDITY CONTROLLER WSK INTELLIGENT TEMPERATU RE AND HUMIDITY CONTROLLER WSK INTELLIGENT TEMPERATU RE AND HUMIDITY CONTROLLER WSK INTELLIGENT TEMPERATURE AND HUMIDITY CONTROLLER WSK INTELLIGENT TEMPERATURE AND HUMIDITY CONTROLLER The wiring diagram subject to the product itself the wiring diagram 485 Frame Size Hole Size Frame Size and Hole Size Frame Size and Installation Hole S...

Страница 5: ...indicator lights The communications light Instrument power light work Increasing Key Decreasing Key Up Key Down Key Displacement Key Mode Key Confirm Key Quit Key Operation Process Boot Up Process Open the Power Self checking of LED device Automatic Automatic Transfomation Transfomation Displaying the current temperature and humidity All LEDS light up Measuring the current temperature and humidity...

Страница 6: ...s the master slave communication response mode connections on a communication line First of all the main computer of the signal only address addressing to a terminal equipment machine and then the response signal from the terminal to transmit to host in the opposite direction i e in a single communication line signal transmission instead of two direction all communication data flow half duplex wor...

Страница 7: ...he address of the query When the terminal sends back a response in the response from the machine address data and tell the host which terminal is to communicate with them ONE ONE ONE ONE TWO TWO CODE Meaning Behavior Function Code Table 2 Tell what is addressing to the terminal to perform the function Listed in the following table shows the supported code function and their meaning and function Ta...

Страница 8: ...ng setting Temperature heater disconnection alarming setting Temperature process alarming setting Humidity process alarming setting Humidity process alarming state Temperature process alarming state ON ON ON ON OFF OFF OFF OFF OFF Lower deviation alarming Lower deviation alarming Higher deviation alarming Higher deviation alarming 3 is the highest brightness the lED display brightness the controll...

Отзывы: