Failure 

Cause of the failure 

Repair

The unit does not start

The Unit does not suck in 
any product

The unit sucks in but does 
not reach the necessary 
pressure (it does not stop 
when the gun is closed)

The product hose vibrates 
abnormally

The unit sucks in and builds 
up pressure when the valve 
is closed, but it decreases 
too much when the trigger is 
pulled

Abnormal spray pattern 
("Horns" and streaks)

Compressed air supply malfunctioning

Malfunction in the pneumatic System
Pressurised Unit

The product container is empty
The suction Filter is obstructed
The suction Probe is loose, blocked or damaged

The pressure Regulator is set at minimum

The purge Valve is closed
The suction Probe is stuck, dirty or damaged
The Piston Valve is stuck, dirty or damaged
Gaskets in poor condition
The hydraulic mechanism is loose or faulty
The purge valve is open or faulty
The Piston Valve is dirty or damaged (It does 
not stop when travelling up nor when travelling 
down)
The Filter is dirty or the suction probe is damaged
There are pockets of air in the Piston

The Piston Valve is dirty or faulty
The bottom Gasket of  the  Piston valve is faulty
The suction Probe and/or the suction Probe are 
loose, dirty or damaged
The suction Probe is damaged
The Gun has no Aircap
The anti-pulsation Filter is blocked
The aircap is worn
The product is too thick
The product is too thick
The pump Pressure is low

The product Filter is blocked
The Aircap is damaged
The anti-pulsation Filter is blocked
The suction Probe and/or the suction Probe are 
loose, dirty or damaged

Make sure the supply hose is not 
obstructed
Make sure the unit is properly connected 
to the mains supply
Make sure the compressed air valve is open

Consult SAT SAGOLA
Depressurise the unit (See Depressurisation 
Procedure described in the Manual)
Refill it
Clean it or replace it
Check the  connection of the probe to the 
unit or replace it
Increase the pressure by adjusting the 
regulator
Open it
Remove it and clean or replace it
Remove it and clean or replace it
Replace them
Tighten it or replace it
Close it or replace it
Clean it or replace it

Clean it or replace it 
Adjust the pressure Regulator (Maximum- 
Minimum) to eliminate the pockets of air 
Clean it or replace it
Replace it
Tighten and/or clean the Probe and Filter, 
or replace elements
Replace it
Assemble the cap
Clean it or  Replace it
Replace it
Reduce its thickness
Reduce its thickness
Increase the pressure by adjusting the 
pressure Regulator
Clean it or Replace it
Replace it
Clean it or  Replace it
Tighten and/or clean the Probe and Filter, 
or replace elements

19. TROUBLESHOOTING

Содержание RAIDER 300

Страница 1: ...i n s t r u c t i o n m a n u a l s p a r e p a r t s l i s t raider...

Страница 2: ......

Страница 3: ...ge 18 8 Service Kits page 18 9 Start up page 18 10 Depressurisation page 18 11 Operation page 19 12 Stopping page 19 12 1 Short stop page 19 12 2 Stopping when work is finished page 19 13 Cleaning pag...

Страница 4: ...sonnel instructed in its use and must be employed only for the purpose for which it was designed Likewise accident prevention standards work centre regulations and directives and current legislation a...

Страница 5: ...ly verify one a week its electrical continuity If its resistance exceeds the recommended limits it must be fixed An equipment unit without or with a faulty grounding connec tion may make the installat...

Страница 6: ...he Technical Service of SAGOLA S A 6 USEFUL TIPS The Raider 300 equipment can be used to apply conveniently diluted products used widely in the Construction Automotive Timber Plastics Industry etc The...

Страница 7: ...maintaining part of the same for example the hand guard in contact with the container being sprayed In a few seconds the product will start to flow from the head of the gun without the air cap Keep t...

Страница 8: ...The gun can be cleaned with thinners or detergents in a gun washing machine If you opt for this cleaning system we advise you to remember the following considerations which if not applied may damage t...

Страница 9: ...lation and regulations Near the unit only keep the amount of product and thinner required for the work being done at that time After work has been completed thinners and the product to be applied must...

Страница 10: ...damaged The suction Probe is damaged The Gun has no Aircap The anti pulsation Filter is blocked The aircap is worn The product is too thick The product is too thick The pump Pressure is low The produc...

Страница 11: ...low Clean it and or Replace it Replace it Do not exceed the maximum recommended work pressures Send the unit to the S A T SAGOLA Replace the gaskets and or the Piston Shaft Check that the air inlet pr...