![background image](http://html1.mh-extra.com/html/sagola/pack-6000x/pack-6000x_instruction-manual_3446405030.webp)
ENGLISH
07. Useful tips
Use the lowest spray pressure in the spray gun or application tool. That which allows you to obtain
the desired finish. Not all products require the maximum pressure to be properly sprayed. With a
lower pressure one will obtain an additional increase in product transfer.
If you install a
pressure regulator
always mount it
before the PACK 6000X
to avoid possible
overheating and dilation of the regulator. Set it to the minimum pressure required to optimise the
performance of the PACK 6000X and save energy.
Please note that not all types of paint can be applied with hot air and that this may even cause
imperfections in the paint finish.
08. Controls and inicators
8.1.- Temperature controller
1
Process value (PV)
Indicates process value. Shows parameter name when in
parameter setting. (Program Value)
2
Set point (SV)
Shows set point. Shows parameter set value when in
parameter setting. (Set value)
3
Screen No.
Shows screen No. when in parameter setting.
4
OUT 1
indicator
Lights during control output 1 is ON.
5
OUT 2
indicator
Lights during control output 2 is ON.
6
EV 1, EV 2, EV 3
indicators
Lights during digital output 1 to 3 are ON.
7
STBY
indicator
Lights during standby.
8
MANU
indicator
Lights during manual mode.
9
Lock indicator
Lights during key lock.
10
No. indicator
Lights during indicating screen No.
11
RUN/HOLD/END
indicators
Lights during ramp/soak operation.
1
2
3
4
5
7
6
8
10
12
13 14 15
11
16
17
9
Содержание PACK 6000X
Страница 2: ...ESPA OL an Elcometer company...
Страница 24: ...ENGLISH an Elcometer company...
Страница 46: ...PORTUGU S an Elcometer company...
Страница 68: ...DEUTSCH an Elcometer company...
Страница 90: ...FRAN AIS an Elcometer company...
Страница 112: ...ITALIANO an Elcometer company...