background image

ENGLISH

When the trigger is pulled back fully,

 the product needle is retracted, 

allowing

 the product to flow 

out.  This is then sprayed in the 

form of a fan

.

When the trigger is released,

 the needle returns to its 

initial position

, first closing off the product 

outlet and then the air valve and 

application stops

.

8. Digital Pressure Gauge

The digital pressure gauge

, built into the gun body, 

indicates the 

internal air pressure 

with a precision of ±0.16 bar or ±1.6 psi (psi 

version), 

when the trigger is pulled back to the first position

. The 

indicator can measure up to 9.9 bar. When the gun is disconnected 

from the compressed air distribution network, pressure measure-

ment is deactivated, thereby increasing the service life of the battery 

that powers the gauge (between 1 and 3 years according to use). 

The digital pressure gauge

 is sealed hermetically against external inferences (maximum tempera-

ture 50°C). Should the gauge not indicate any pressure, you must replace the battery and the 

gasket fitted to the plug.

The housing of the digital pressure gauge must be opened only to replace the battery. If necessary, 

also replace the gasket mounted in the plug of the device. Should this not be done, the warranty 

will be rendered null and void.

For correct operation, the digital pressure gauge continuously measures the pressure inside the 

pistol, while there is a power supply through the battery.

WARNING!!

The battery cannot be replaced in hazardous areas.

See Atex regulations about explosion risk areas.

The digital pressure gauge must not be handled in potentially explosive areas.

In order to make any check, repair or operation, first disconnect the unit from the compressed air 

network. 

Should there be any malfunction in the pressure gauge, its sight glass or any of its components, 

the gun must be disconnected and repaired by the Technical Services of 

SAGOLA S.A.

 If this not 

be done, 

ATEX

 approval will be lost.

The digital pressure gauge has been subjected to a conformity check and has been developed and 

manufactured in accordance with Community Directive 94/9 CE.

It was assembled according to:      II 2G Ex ia IIC T4 Gb

   

 

In explosion areas 1 and 2 it can be used in temperatures of up to 50°C.

9. Tips and Needles Kits

SAGOLA S.A.

 supplies 

Nozzle Kits and Tip and Needle Kits

 of different 

sizes for a variety of different applications. In order to replace these, 

proceed as follows:

With the gun fully depressurised, remove the air nozzle.

Remove the product regulator

 with the 

spring 

and the

 spring stop

 and

 extract the needle

 to be 

replaced.

 Remove the tip

 with the wrench supplied.

 

Fit the new tip and tighten. Now fit, 

in this order, 

the new needle, the spring 

and

 spring stop 

and 

the

 product regulator. 

Lastly,

 fit the 

appropriate

 air nozzle.

There are Tip + needle Kits for this model of Ø 1.20, 1.20XL, 1.30, 1.30XL and 1.40.

22/23

Содержание 4600 Xtreme

Страница 1: ...l d e i n s t r u c c i o n e s i n s t r u c t i o n m a n u a l m a n u a l d e i n s t r u e s g e b r a u c h s a n l e i t u n g l i b r e t t o d i i s t r u z i o n i m a n u e l d u t i l i s...

Страница 2: ...ge 24 11 1 Clean Air 11 2 Sufficient volume of air 11 3 Adjusting Air Pressure 11 3 1 Digital Pressure Gauge Version 11 3 2 Analogue Pressure Gauge Version 11 3 3 Version without Pressure Gauge 11 4 A...

Страница 3: ...ipment consists of the following _ Spray gun _ Accessory wrench _ Cleaning brush _ Instruction manual _ Case 3 Technical details Unit with product feed by gravity hereinafter the Gun with Tip and Air...

Страница 4: ...onents these come into contact with aluminium stainless steel polythene and acetylene resin Do not use corrosive or abrasive products The gun has been designed for long service and can be used with th...

Страница 5: ...ted Increase the amount of product correct its viscosity or use a larger fluid tip in the gun If the thickness of the layer is very thin this is due to the fact that the air pressure is excessive for...

Страница 6: ...the pressure inside the pistol while there is a power supply through the battery WARNING The battery cannot be replaced in hazardous areas See Atex regulations about explosion risk areas The digital p...

Страница 7: ...rning these anticlockwise See Fig 1 and Fig 2 Place the pistol on a support so that the axis of the tank is vertical Pour the product to apply into the tank Until the level is a maximum of 20 25 mm be...

Страница 8: ...air hoses Should an antistatic air hose not be available you must attach the unit to a ground connection in order to eliminate any static electricity The total derivative resistance must be 100 millio...

Страница 9: ...t condition IN ORDER TO OBTAIN THE BEST POSSIBLE RESULTS ALWAYS USE ORIGINAL SPARES ENSURE TOTAL INTERCHANGEABILITY SAFETY AND OPERATION 12 1 Changing the self adjusting Packing gland The needle gaske...

Страница 10: ...er 12 3 Cleaning or replacement of the product filter If there is any cleaning liquid or product remaining in the tank return it to its corresponding containers To avoid any spillage keep the pistol i...

Страница 11: ...U V A 02 03 18 16 28 15 13 14 12 19 20 22 10 24 23 25 11 21 21 26 10 06 08 06 07 09 29 04 17 1 2 ESP U V A 1 DVR TITANIA 2 DVR HVLP 3 DVR AQUA 4 DVR CLEAR 1 BAR 2 PSI 05 27 1 1 20 2 1 20 XL 3 1 30 4 1...

Страница 12: ...ning of the gun tools and accessories used in the mixing and preparation of the product to be applied we recommend the use of SAGOLA washing machines IMPORTANT The gun can be cleaned with thinners or...

Страница 13: ...eing done at that time After work has been completed thinners and the product to be applied must be returned to their corresponding storage location Keep the working area clean and free of potentially...

Страница 14: ...y to use personal protective equipment such as gloves to thermally insulate your hands from the unit The use of solvents and or detergents that contain halogenated hydrocarbons trichloroe thane methyl...

Страница 15: ...the case of any breakdown during the guarantee period please attach the completed warranty certificate to the unit and deliver this to the nearest Technical Assistance Service or get in touch with th...

Страница 16: ...pray width regulator Dirty or damaged Tip Nozzle joint Blockages or dents in the air nozzle or fluid tip Dirty air nozzle Inadequate air pressure Inadequate amount of product Inadequate viscosity Spra...

Страница 17: ...e 2014 34 UE UNE EN 60079 0 2013 A11 2014 Electric material for explosive gas environments Part 0 General requirements UNE EN 60079 11 2013 Explosive environments Part 11 Protection of the equipment f...

Страница 18: ...at Kaufdatum Data de Compra Data di aacquisto E mail Sello Stamp Cachet Stempel Selo Timbro Tel Fax GUARANTEE C0NDITIONS CONDITIONS DE GARANTIE CONDICIONES DE GARANT A CONDI ES DA GARANTIA CONDIZIONI...

Страница 19: ...ELLE TECHNISCHER DIENST PROFESSIONNELLE REPARATURGARANTIE SERVI O DE ASSIST NCIA T CNICA GARANT A DE REPARA AO PROFISSIONAL SERVIZIO DI ASSISTENZA TECNICA GARANZIA DI RIPARAZIONE PROFESSIONALE SAGOLA...

Отзывы: