background image

 

Page 2 : Fixture Parameters 

The following table shows how to set the fixture’s parameters on SETUP page 2. 
LED 1-2 

OFF-OFF: the fixture attributes are configured as extended (see the attributes table) 
OFF-ON: the fixture attributes are configured as reduced (see the attributes table) 
ON-OFF: the fixture is configured as MASTER (see macro table) 
ON-ON: the fixture is configured as SLAVE, in other words it receives the commands 

from the MASTER fixture. 

LED 3 

OFF: W-DMX ™ is disabled 
ON: W-DMX ™ is enabled 
Note: activating the internal W-DMX ™  receiver does not exclude the DMX wire 

connection. Unplug the DMX cable if you want to use only the W-DMX ™. 

LED 4-7 

When the fixture is configured as MASTER these bits set the macro (see macro table) 

LED 8-9 

When the fixture is configured as MASTER these bits set the macro speed: 
OFF-OFF: the macro runs at 1/8 speed (slower) 
OFF-ON: the macro runs at 1/4 speed 
ON-OFF: the macro runs at 1/2 speed 
ON-ON: the macro runs at full speed (faster) 

Enable and Pair the W-DMX™ 

Entering in SETUP mode is possible to check the W-DMX™ status by means of the 

W-DMX BLUE 

LED

A)

 

W-DMX BLUE LED is OFF

: the unit has not been paired before with a transmitter and it 

waits to be paired with one transmitter;

 

B)

 

W-DMX BLUE LED is fixed ON

: the unit has been paired before with a transmitter and the 

transmitter is active;

 

C)

 

W-DMX BLUE LED is flashing

: the unit has been paired before with a transmitter but the 

transmitter is turned off or missing or different.  The unit waits  for  the transmitter 

previously paired to change its  status  as B.  In case you want to pair it with another 

transmitter you have to un-pair the unit changing its status as A, with a method explained 

below.

 

To enable the W-DMX 

go to LED 3 of page 2, press the ENT key one time to switch the LED 3 to ON 

position. Please note that enabling the W-DMX doesn’t mean that the unit is paired, but that the 

unit is able to receive DMX data from the wireless. 

To disable the W-DMX 

go to LED 3 of page 2, press the ENT key one time to switch the LED 3 to 

OFF position. Please note that disabling the W-DMX doesn’t mean that the unit is unpaired, but 

that the unit is unable to receive DMX data from the wireless.

 

To pair fixtures to a transmitter press the red button on the transmitter for 1 second (Pairing 

receivers)

: all QUARIUX that are turned on and that are not paired before to another transmitter 

(status A) will be paired with this transmitter (status B). 

17 

 

Содержание QUARIUX

Страница 1: ...Rev 44 18 6x30W COB led bar User Manual...

Страница 2: ...2...

Страница 3: ...Aiming 9 Hook up the Safety Rope 10 LED Bar linking 10 Vertical array linking 11 SSZ Solid state zoom only some models 11 Rear Panel 12 Connections 13 Connection Example 14 Control Panel 15 Setup Mode...

Страница 4: ...amages to unit should be immediately notified to forwarder Each complaint for manumitted package should be done within eight days from product receipt WARRANTY AND PRODUCTS RETURN Proel products have...

Страница 5: ...ng symbol with arrow in an equilateral triangle intends to alert the user to the presence of not insulated dangerous voltages within the product s enclosure that may be of sufficient magnitude to cons...

Страница 6: ...e internal temperature goes below the operative limit The maximum temperature of the housing is Tc 70 C ensuring the correct ventilation to the fixture frame IP67 PROTECTION RATING The device is prote...

Страница 7: ...authorized maintenance center CE Conformity PROEL S p A hereby declares that this product complies with the essential requirements and other relevant provisions of Directive 2014 35 EU LVD as stated i...

Страница 8: ...curves selectable Protocol USITT DMX 512 Master Slave mode Preset macro colors with speed regulation Static Color static reproduction of one color Touch pad with led indicators Integrated wireless dmx...

Страница 9: ...Use the centre 13mm hole for an ALISCAF or Hook clamp to fix the bracket at a stage structure or use the 9mm holes for wall ceiling mounting The light beam of the LED bar can be aimed with 20 steps ar...

Страница 10: ...optional PLH232 safety rope can be fixed in one of the four angular arrow holes as shown in the figure below The rope must be arranged so that it has the shortest travel possible in case of its inter...

Страница 11: ...tate zoom is a feature available only in some models identified by a Z letter as last letter in the code name of the fixture It consists of a frost filter that can be controlled by a proper DMX channe...

Страница 12: ...LED bar if not used it should be kept closed using the provided plug WARNING the maximum number of linkable QUARIUX is 8 units The rear panel features also a GORE Protective Vent which is used to equa...

Страница 13: ...ided by a qualified operator following the instructions below The previous instructions also show how to arrange an output connection to link more than one QUARIUX unit using an ECO MATEm male connect...

Страница 14: ...Connection Example 14...

Страница 15: ...atus LED needed to set properly the fixture The LED are working only in SETUP MODE as described in the following paragraph The upper status LED is blue it lights up when the W DMX is active it stays o...

Страница 16: ...set up summing the corresponding number of each setting LED that is ON Setting LED 1 2 3 4 5 6 7 8 9 Number to sum 1 2 4 8 16 32 64 128 256 So if you want to set the number 200 you have to turn ON the...

Страница 17: ...unit has not been paired before with a transmitter and it waits to be paired with one transmitter B W DMX BLUE LED is fixed ON the unit has been paired before with a transmitter and the transmitter is...

Страница 18: ...e Range Description 1 Red 0 255 0 No red 255 maximum 2 Green 0 255 0 No green 255 maximum 3 Blue 0 255 0 No blue 255 maximum 4 White 0 255 0 No white 255 maximum 5 Dimmer 0 255 Light intensity dimmer...

Страница 19: ...nnected via DMX cable The following table shows the pre configured macros on RGBW and RGBWZ models Macro LED 4 LED 5 LED 6 LED 7 Brief effect description 1 OFF OFF OFF OFF Rainbow Fade 100 2 OFF OFF O...

Страница 20: ...PROEL S p A World Headquarters Factory Via alla Ruenia 37 43 64027 Sant Omero Te Italy Tel 39 0861 81241 Fax 39 0861 887862 www proel com www sagitter com 20...

Отзывы: