34
3222180_GB
THAWING
The defrost cycles with probe or by time are automatic. During the cycle the parameters can be modified and
the temperature can be selected or the time at which the food should be defrosted and ready for use.
In the event of time defrosting the operator can decide to change only the cycle end date acting on the date
on the screen of the cycle in progress. This action is valid only if you are in the first phase (preservation)
1.
Select MENU by rotating the knob
SOFT -18°C
HARD -18°C
IFR
INFINITY
SOFT +3°C
HARD +3°C
MENU
2.
Press the knob to enter section MENU
SOFT -18°C
HARD -18°C
IFR
INFINITY
SOFT +3°C
HARD +3°C
MENU
3.
Select FUNCTIONS by rotating the knob
AUTOMATIC
MULTY
COOLING
STORED
SETTING
SERVICE
HACCP
FUNCTIONS
MENU
4.
Press the knob to enter section
FUNCTIONS
AUTOMATIC
MULTY
COOLING
STORED
SETTING
SERVICE
HACCP
FUNCTIONS
MENU
5.
Select THAWING by rotating the knob
DEFROST
STORAGE
THAWING
SANITATION
MENU
FUNCTIONS
PROBE HEATING
PROVING
6.
Press the knob to enter into the
THAWING
MENU
FUNCTIONS
DEFROST
STORAGE
THAWING
SANITATION
PROBE HEATING
PROVING
7.
Rotate the knob to select the type most
suited for the product to be treated
ICE CREAM TIME
TIME
ICE CREAM PROBE
THAWING
PROBE
8.
Press the knob to activate the selected
cycle
In case of time defrosting the cycle will begin
immediately with the date and time values
set by the manufacturer.
-
Once the cycle has been started (time
defrosting) the cycle end date and time can
be changed, but only during the first phase
(preservation).
ICE CREAM TIME
TIME
ICE CREAM PROBE
THAWING
PROBE
12:56
SET
STOP
100%
+25°C
+24°C
02/10/2013 17:28