21
3222180_GB
STANDARD PROGRAMMES
Chilling/freezing cycles pre-set by the manufacturer which can be activated by selecting them directly from
the initial screen, SOFT +3°C, HARD +3°C, SOFT -18°C and HARD -18°C.
During execution of the cycle the parameters can be viewed and modified temporarily. The new values will
be valid exclusively for the cycle in progress.
1.
Select the desired cycle by rotating the
knob
SOFT -18°C
HARD -18°C
IFR
MENU
INFINITY
SOFT +3°C
HARD +3°C
2.
Press the knob to activate the selected
cycle
During the cycle it is possible:
- to view and modify the default parameters by
selecting SET (see page 40)
- to stop the cycle by selecting STOP
Note: the modified parameters will be saved only
for the cycle in progress
SOFT -18°C
HARD -18°C
IFR
MENU
INFINITY
SOFT +3°C
HARD +3°C
90'
HARD +3°C
100%
+27°C
+24°C
SET
STOP
3.
Cycle ended, automatic conservation
phase
During conservation it is possible:
- to view and modify the default parameters by
selecting SET (see page 40)
- to activate a manual defrost by selecting
- to stop the cycle by selecting STOP
Note: the modified parameters will be saved only
for the cycle in progress.
If not required, manual defrosting is not performed
- -
END CYCLE
CONSERVE
100%
+27°C
+24°C
SET
STOP