Proc Sheet 1 31
myZ-5
5HPRYHDQG3ODFH
7KHNH\SDGRIWKHXSSHUFDVLQJRI)/$3
1/2
7RROV
- Phillips screwdriver.
-
Plectrum
-
Gloves
3UHOLPLQDU\RSHUDWLRQ
1. Remove the battery (
Proc sheet 0 01
).
2. Remove the lower casing of mobile (
Proc sheet 1 01
).
3. Remove the equipped electronic board (
Proc Sheet 1 18
).
4. Remove the upper casing of mobile (
Proc Sheet 1 13
).
5. Remove the lower casing of FLAP (
Proc Sheet 1 26
).
6. Remove the FPC (
Proc Sheet 1 30
).
7. Remove the MMI Display (
Fiche proc 2 04
).
5HPRYDOSURFHGXUH
1. Remove the navigator keypad (1).
3ODFHPHQWSURFHGXUH
1. Clean the keypad with a comprimed air (2).
2. Position a new navigator keypad in its place (2).
)XUWKHURSHUDWLRQV
1. Place the MMI Display (
Fiche proc 2 04
).
2. Place the FPC (
Proc Sheet 1 30
).
3. Place the lower casing of FLAP (
Proc Sheet 1 26
).
4. Place the upper casing of mobile (
Proc Sheet 1 13
).
5. Place the equipped electronic board (
Proc Sheet 1 18
).
6. Place the lower casing of mobile (
Proc sheet 1 01
).
7. Place the battery (
Proc sheet 0 01
).
Risk of the procedure:
•
Damage the navigator
keypad.
•
Damage casings.
Procedure
Symptom
Test
REF MTB DTS 9- Indice B - December 09 2005
Page 5-27