Proc Sheet 2 02
myZ-5
5HPRYHDQG3ODFH
7KHORXGVSHDNHU
1/1
7RROV
- Phillips screwdriver
- Soldering iron
- Plait to be unsolder
- Plectrum
- Gloves
3UHOLPLQDU\RSHUDWLRQ
1. Remove the battery (
Proc sheet 0 01
).
2. Remove the lower casing of mobile (
Proc sheet 1 01
).
3. Remove the equipped electronic board (
Proc Sheet 1 18
).
4. Remove the upper casing of mobile (
Proc sheet 1 13
).
5. Remove the lower casing of FLAP (
Proc sheet 1 26
).
6. Remove the FPC (
Proc sheet 1 30
).
7. Remove the MMI LCD (
Proc Sheet 2 04
).
5HPRYDOSURFHGXUH
1. Unstuck the loudspeaker of its housing (1) .
2. Remove the loudspeaker defective.
3ODFHPHQWSURFHGXUH
1. Flux the place of the loudspeaker and solder it on the equipped MMI display, respecting the wiring sense
(1).
)XUWKHURSHUDWLRQV
1. Place the MMI LCD (
Proc Sheet 2 04
).
2. Place the FPC (
Proc sheet 1 30
).
3. Place the lower casing of FLAP (
Proc sheet 1 26
).
4. Place the upper casing of mobile (
Proc sheet 1 13
).
5. Place the equipped electronic board (
Proc Sheet 1 18
).
6. Place the lower casing of mobile (
Proc sheet 1 01
).
7. Place the battery (
Proc sheet 0 01
).
Risk of the procedure:
•
Damage the MMI display.
•
Oxide the MMI Display.
•
Reverse the loudspeaker wiring.
•
Damage the new loudspeaker.
Procedure
Symptom
Test
REF MTB DTS 9- Indice B - December 09 2005
Page 5-32