Safety precautions

 

 

General

: The product TAINY GMOD-T1 complies with European standard EN60950, 05.2003, Safety 

of Information Technology Equipment. 
Read the installation instructions carefully before using the device. 
Keep the device away from children, especially small children.  
The device must not be installed or operated outdoors or at damp locations.  
Do not operate the device if the connecting leads or the device itself are damaged. 

External power supply

: Use only an external power supply which also complies with EN60950. The 

output voltage of the external power supply must not exceed 30VDC. The output of the external power 
supply must be short-circuit proof. 
When connecting to a battery or accumulator, make sure that an all-pole circuit-breaker (main battery 
switch) with sufficient selectivity and a fuse with sufficient selectivity are provided between the device 
and the battery or accumulator. 
Please pay regard to section 

Technical Data

 of the installation manual, as well as the installation and 

utilisation regulations of the respective manufacturers of the power supply, the battery or the 
accumulator. 

SIM card

: To install the SIM card the device must be opened. Before opening the device, disconnect 

it from the supply voltage. Static charges can damage the device when it is open. Discharge the 
electric static of your body before opening the device. To do so, touch an earthed surface, e.g. the 
metal casing of the switch cabinet. Please pay regard to section 

Inserting or changing the SIM card

 of 

the installation manual.  

Handling cables

: Never pull a cable connector out of a socket by its cable, but pull on the connector 

itself. Cable connectors with screw fasteners (D-Sub) must always be screwed on tightly. Do not lay 
the cable over sharp corners and edges without edge protection. If necessary, provide sufficient strain 
relief for the cables. 
For safety reasons, make sure that the bending radius of the cables is observed.  
Failure to observe the bending radius of the antenna cable results in the deterioration of the system's 
transmission and reception properties. The minimum bending radius static must not fall below 5 times 
the cable diameter and dynamic below 15 times the cable diameter. 

Radio device

: Never use the device in places where the operation of radio devices is prohibited. The 

device contains a radio transmitter which could in certain circumstances impair the functionality of 
electronic medical devices such as hearing aids or pacemakers. You can obtain advice from your 
physician or the manufacturer of such devices. To prevent data carriers from being demagnetised, do 
not keep disks, credit cards or other magnetic data carriers near the device. 

Installing antennas

: The emission limits as recommended by the Commission on Radiological 

Protection (13/14 September 2001) must be observed. 

Installing an external antenna

: When installing an antenna outdoors it is essential that the antenna 

is fitted correctly by a qualified person. Lightning Protection Standard VDE V 0185 Sections 1 to 4, in 
its current version, and further standards must be observed. 

Lightning protection category for buildings

: For outdoor installation, the antenna may be fitted only 

within the lightning protection zones O/E or 1. These lightning protection zones are prescribed by the 
lightning protection spherical radius. 

The EMV lightning protection zone concept

 is to be observed. To avoid large induction loops a 

lightning protection equipotential bonding is to be used. If the antenna or antenna cable is installed 
near to the lightning protection system, the minimum distances to the lightning protection system must 
be observed. If this is not possible, insulated installation as described in VDE V 0185 Sections 1 to 4, 
in its current version, is essential.

 

Содержание Dr. Neuhaus Tainy GMOD-T1

Страница 1: ...File 3159AD001_V1_3_050701 doc File saved 01 07 2005 File printed 01 07 2005 State Freigabe Autor Katharina Bora TAINY TAINY TAINY TAINY GMOD GMOD GMOD GMOD T1 T1 T1 T1 Installation Manual...

Страница 2: ...n tightly Do not lay the cable over sharp corners and edges without edge protection If necessary provide sufficient strain relief for the cables For safety reasons make sure that the bending radius of...

Страница 3: ...File printed 01 07 2005 State Freigabe Autor Katharina Bora Warning This is a class A equipment This equipment can disturb other electric equipment in living areas in this case the operator can be dem...

Страница 4: ...the GSM engine Recommended 12 Switching off 12 2 4 Installing the modem driver under Windows 13 2 5 Setting up the dial up connection under Windows 17 Purpose of the dial up connection 17 Set up the...

Страница 5: ...IP connections via the GPRS General Packet Radio Service of a GSM network Global System for Mobile Communication mobile radio network Modem connections by CSD Circuit Switched Data Fax connections Sen...

Страница 6: ...3 Installing the modem driver under Windows 13 4 Setting up the dial up connection under Windows 17 Connections and LEDs LED Status Meaning On permanently Operating voltage on P Power Off No operating...

Страница 7: ...d off when you insert or change the SIM card A plug in SIM card 3 V is used 1 Make sure that the device is disconnected from the supply voltage 2 The TAINY GMOD T1 must be opened to insert the SIM car...

Страница 8: ...the motherboard 6 With a suitable object open the flap of the SIM card holder by moving it cautiously about 2 mm to the left in the direction of the arrow see red arrow in the illustration so that it...

Страница 9: ...the SIM card into the flap of the SIM card holder with the gold coloured microchip pointing down The flap has a groove for this purpose The notched corner of the SIM card has to point towards the fro...

Страница 10: ...ht in the direction of the arrow until you can feel it click into place 12 Now the SIM card holder is locked into position 13 Finally re attach both housing parts Slide the motherboard into the rails...

Страница 11: ...terminals on the top of the device are for connecting the current supply 24 V DC voltage nominal Ityp 220mA 24V Please also refer to chapter Technical Data page 29 24 V 24 V SW 12 30VDC 0 V Both scre...

Страница 12: ...ters Connecting the device and Technical Data Switching on The devices switches on as soon as the operating voltage is supplied and the switch input SW is active Switching off the GSM engine Recommend...

Страница 13: ...ingly Under Windows 2000 or Windows XP you must be registered as the administrator In addition please make sure that no other modem drivers are or will be installed for the respective interface Follow...

Страница 14: ...File saved 01 07 2005 File printed 01 07 2005 State Freigabe Autor Katharina Bora When this dialogue box is displayed Select Don t detect my modem I will select it from a list Then click on Next 5 Cli...

Страница 15: ...arina Bora 6 In the next dialogue box change to the inserted CD ROM and then to the Driver folder Select TAINY_MOD_T1 INF Follow the instructions on the screen Click on Next 7 Next you are asked to se...

Страница 16: ...D001_V1_3_050701 doc File saved 01 07 2005 File printed 01 07 2005 State Freigabe Autor Katharina Bora 9 Click on Finish 10 When installation is completed the installed modem driver will be listed in...

Страница 17: ...P connection It is not necessary to set up a dial up connection for data transfer e g by terminal program fax transmissions SMS Short Message Service Set up the dial up connection The following instru...

Страница 18: ...MOD T1 File 3159AD001_V1_3_050701 doc File saved 01 07 2005 File printed 01 07 2005 State Freigabe Autor Katharina Bora 2 The New Connection Wizard is launched Click on Next 3 Select Connect to the In...

Страница 19: ...ile printed 01 07 2005 State Freigabe Autor Katharina Bora 4 Select Set up my connection manually and click on Next 5 Select Connect using a dial up modem and click on Next 6 When you are asked to cho...

Страница 20: ...2005 State Freigabe Autor Katharina Bora 7 Give the dial up connection service a name that describes your purpose Then click on Next 8 Type the phone number for access to the Internet 99 1 Then click...

Страница 21: ...1 07 2005 File printed 01 07 2005 State Freigabe Autor Katharina Bora 9 Enter your user name and password here You will find them in your subscription contract Or you can ask your mobile telephone com...

Страница 22: ...site The DNS server of your network operator for GPRS connections is configured in the dial up network connection In order to do so please proceed as follows 1 Open the Properties dialog box of the di...

Страница 23: ...her modem You will find a list of all supported AT commands in the PDF file AT Command Set on the CD supplied The various functions of the device are not necessarily all operated by the application us...

Страница 24: ...r example the standard APN of your GSM network operator for access from the GPRS network to the Internet for T Mobile in Germany it is internet td1 de Or it is the APN for access to your corporate net...

Страница 25: ...dial up connection to the Internet Making the connection 1 Double click on the icon representing the connection Consequence The dialogue box for making a connection appears 2 Click on Dial When the co...

Страница 26: ...Until a PIN has been entered most AT commands will be answered with ERROR Working with a terminal program To be able to control the device directly via AT commands use a terminal program e g HyperTer...

Страница 27: ...There are only two exceptions to this rule The command to switch to Command Mode see below and the command A with which the last command line is repeated Command Mode Transparent Mode The device accep...

Страница 28: ...0 0 0 0 0 0 Sets APN OK ERROR AT CREG Checks status in GSM network CREG 0 1 registered CREG 0 3 reg denied CREG 0 5 roaming AT CSQ Checks signal quality CSQ xx 99 0 xx 31 xx should be greater than 10...

Страница 29: ...t Ityp 430mA 12V IPeak 1 2A Ityp 220mA 24V Voltage supply Switch input Iswitch max 1mA Temperature range Operating 20 C up to 70 C 55 C Derating Storage 25 C up to 85 C Ambient conditions Humidity 0 9...

Страница 30: ...Data Page 30 of 31 TAINY GMOD T1 File 3159AD001_V1_3_050701 doc File saved 01 07 2005 File printed 01 07 2005 State Freigabe Autor Katharina Bora Switch input 24V 0V 24V SW ON 24V 0V 24V SW OFF Iswitc...

Страница 31: ...ge without notice TAINY is a trademark of Dr Neuhaus Telekommunikation GmbH All other trademarks and product names are trademarks registered trademarks or product names of the respective title holders...

Отзывы: