AFL IV with Dynamometer
Sage Technologies, Inc. www.sageoiltools.com 49
Once the data begins to display, you save individual dynamometer cards by clicking the
Save
Dynamometer Card
button.
Once you have collected enough dynamometer cards, click
Next
to move on to
Valve Checks
.
Note:
When doing valve checks using the
Quick Clamp Load Cell
, the load initially will be displayed as
an A-D reading, rather than as an actual load. Do not let this bother you; when the test is complete, all
readings are converted to actual load using the rod string data. Also, if you need to change the rod string
data later, because of a data entry mistake, the values will automatically recalculate.