Configure the SMOS Director Function

1. Using the 

BACK

 and 

NEXT

 keys, navigate to the Main

menu

2. Using the numeric keypad, press the "

1

" key to select Test

3. Using the numeric keypad, press the "

1

" key to select SMOS

Director

4. Using the numeric keypad, enter the phone number of the

telephone this 925VST is connected to. This information will
be included in the test result logs saved by the 925VST.

Note:

 The following steps 5 through 13 are optional, but are

included to acquaint you with the available user-adjustable
parameters

5. Press the F2 key to display additional setup options

6. Use the numeric keypad to enter 

1, 2, 3,

 or 

4

. Pressing 

4

 sets

all three parameters to factory default values. Let's assume
you want to view or modify each of these parameters. Press
the "

1

" key to select Voice Duration.

This parameter defines how long the SMOS artificial voice
signal will last in each test direction. Default is 9 seconds. On
poor quality circuits (i.e. with significant frame slips, and
frame losses), a longer artificial voice duration will yield
more accurate results. In such cases, Sage recommends
setting the artificial voice duration to 30 seconds or more.

7. After you have made any desired adjustment, press the

NEXT

 key to "enter" your input and return to the previous

setup screen

Main Menu

9

1:<Test>
2:Setup
3:View Results

Test Select

9

1:<SMOS Director>
2:Echo Sounder
3:PVIT Send/Meas

Phone # Under Test,

<SETUP>

Phone # Under Test,
8315551212

<SETUP>

1:<Voice Duration>
2:TX TLP
3:RX TLP
4:Set to Default

SMOS Artificial
Voice Duration
9  Seconds
Enter 3 to 60

SMOS Artificial
Voice Duration
9  Seconds
Enter 3 to 60

1:<Voice Duration>
2:TX TLP
3:RX TLP
4:Set to Default