925VST-TestingTVoIPphones.wpd
Page 4 of 6
jls August 17, 2005
Configure the SMOS Director Function
1. Using the
BACK
and
NEXT
keys, navigate to the Main
menu
2. Using the numeric keypad, press the "
1
" key to select Test
3. Using the numeric keypad, press the "
1
" key to select SMOS
Director
4. Using the numeric keypad, enter the phone number of the
telephone this 925VST is connected to. This information will
be included in the test result logs saved by the 925VST.
Note:
The following steps 5 through 13 are optional, but are
included to acquaint you with the available user-adjustable
parameters
5. Press the F2 key to display additional setup options
6. Use the numeric keypad to enter
1, 2, 3,
or
4
. Pressing
4
sets
all three parameters to factory default values. Let's assume
you want to view or modify each of these parameters. Press
the "
1
" key to select Voice Duration.
This parameter defines how long the SMOS artificial voice
signal will last in each test direction. Default is 9 seconds. On
poor quality circuits (i.e. with significant frame slips, and
frame losses), a longer artificial voice duration will yield
more accurate results. In such cases, Sage recommends
setting the artificial voice duration to 30 seconds or more.
7. After you have made any desired adjustment, press the
NEXT
key to "enter" your input and return to the previous
setup screen
Main Menu
1
9
1:<Test>
2:Setup
3:View Results
Test Select
1
9
1:<SMOS Director>
2:Echo Sounder
3:PVIT Send/Meas
Phone # Under Test,
<SETUP>
Phone # Under Test,
8315551212
<SETUP>
1:<Voice Duration>
2:TX TLP
3:RX TLP
4:Set to Default
SMOS Artificial
Voice Duration
9 Seconds
Enter 3 to 60
SMOS Artificial
Voice Duration
9 Seconds
Enter 3 to 60
1:<Voice Duration>
2:TX TLP
3:RX TLP
4:Set to Default