Configure for 4-Wire Dry Circuit Operation

1. Power up the 925VST. You should see a screen like the

illustration at the right

2. Press the 

NEXT

 key to see the Main Menu

3. Using the numeric keypad, press the "

2

" key to enter the

Setup area

4. Using the numeric keypad, press the "

1

" key to select the

Interfaces screen

5. Using the numeric keypad, press the "

1

" key to select Test

Interface

6. Press the down-arrow button to see additional choices

7. Using the numeric keypad, press the "

2

" key to select 4 Wire

Dry, which is the test interface necessary to connect to the
handset jack of an IP Phone, or headset jack of a WiFi phone.
You will see briefly displayed "Interface is 4W, Dry Mode"

Then, the display will return to the Select Interface screen,
with line 2 enclosed by "greater than" and "less than"
symbols.

8. Press the 

BACK

 key three times to return to the Main Menu

Sage Instruments

925VST 2.9001

2 Wire Mode

Hit Next to Continue

Main Menu

9

1:<Test>
2:Setup
3:View Results

1:<Interfaces>
2:Environment
3:Phone Lists
4:Responder Mode

Interfaces
1:<Test Interface>
2:Serial Port

Select Interface

9

1:<2W Loop 600>
2:2W Loop 900
3:2W Gnd-Start 600

Select Interface

2

8

1:2W Gnd-Start 900
2:4 Wire Dry

Interface is 4W,
Dry mode

Select Interface

2

8

1:2W Gnd-Start 900
2:<4 Wire Dry>