Section 4 :Electrical Interface
44
This document and the information therein are the property of
Safran Identity & Security
.
They must not be copied or communicated to a third party without the prior written authorization of Safran
2017_2000024418 - V1
RS485
Figure 21: Serial port wiring – RS485
9
Blue / Black
RS4 In/Out RS485 Rx/Tx non inverting signal
11 Blue / White
RS485_RXTX-
In/Out RS485 Rx/Tx inverting signal
7
Black / Red
RS485_GND
Ground
RS485 implementation is limited to half-duplex communication. So only Tx+, Tx- and
ground reference signals are necessary.
Depending on the RS485 network, an impedance adaptation may be required.
For farthest terminal, a 120-Ohms resistor termination may be added outside the
terminal between TX+ and TX-.
RS422
Figure 22: Serial port wiring – RS422
9
Blue / Black
R
In
RS422 non inverting Receive
11 Blue / White
RS422_RX-
In
RS422 inverting Receive
12 Green / Black
R
Out
RS422 non inverting Transmit
10 Green / White
RS422_TX-
Out
RS422 inverting Transmit
7
Black / Red
RS485_GND
Ground
RS422 interface is a full duplex communication.