background image

 

SAFIRE 2400Di, 2600Di, 3200Di and 3600Di Diesel / fuel oil heaters 

4

 

 

USAGE, INSTALLATION AND MAINTENANCE 

 

 

January 2012 

SF_ Lämmitin Oy

 Tilhenkatu 1 20610 Turku Finland Puh/Fax +358(0)2-2443282 

 

 

USAGE 

 

BEFORE USING THE HEATER 

 

Before using the heater make sure that 

• the tank and the fuel hose are properly installed 

• the heater is properly attached to the mounting bracket 

• the combustion air, circulation air and exhaust can flow freely 

• there aren’t any foreign objects inside or near the heater or in its exhaust outlet, or substances which are 

flammable or can produce smells. 

 

Fuel 

 

The best fuel is winter grade light fuel oil, or off-road gas oil. If you can’t find winter grade fuel during the summer, 

you can use summer grade light fuel oil or paraffin oil. To remove condensation water, add about 2% isopropanol-

based antifreeze for gasoline engines (not antifreeze for diesel engines!) to the fuel. 

If you don’t use the heater in the winter and store it in a cold place, use paraffin oil the last time you use the 

heater, and leave the fuel hoses full (paraffin oil has a low cloud point). Paraffin oil will protect the hose from 

freeze. 

 

CONTROLLING THE HEATER AND INDICATOR LEDS 

 

Basic control panel  

 

Start: turn the switch to position “HEAT/ON”. 

Ventilation: turn the switch to position “VENT”. 

Turn off: turn the switch to position “OFF”. 

Adjust heating power, temperature (heaters with thermostat)  

or ventilation power (if the ventilating mode is active) with the  

adjustment knob. To obtain the normal room temperature,  

turn the adjustment knob to point upwards.  

 

 

 

 

 

 

 

GENIUS control panel 

Turn the heater on or off according to the instructions on the display. 

Return to the main menu with “BACK”-button. Scroll the main menu with  

arrow keys, choose an item with “OK”-button.  

NB!: After a power failure the time must be set again.  

 

 

 

 

 

SAFIRE 3000

 

SAFIRE

                 

BACK

OK

Hallinta

Ajastin

Asetukset

Termostaattin ytt

Made in Finland by 

SF-L mmitin Oy 

genius

 

Содержание 2400Di

Страница 1: ...e plenty of heat Minimize their length and isolate them carefully It is more economic to place the heater close to the space to be heated and use a separate fresh air inlet You don t have to isolate the warm air hoses inside f ex under the bed the hoses function as radiators for they dry the space and balance the temperature differences Remember also that as the heater blows warm air inside an equ...

Страница 2: ... pump Attach the fuel hoses carefully and protect them from heat or mechanical strain Exhaust outlet Exhaust is led out and combustion air taken in through hull with a coaxial exhaust outlet For installing the outlet you need to make one Ø 50 mm hole and four 5 5 mm holes use the outlet end as a model Cut the inner pipe a bit too long so that it can t slip from its place Bend the exhaust outlet ho...

Страница 3: ...at least 6 mm 2 thick NB The housing of the heater is galvanic connected to the minus pole of the battery You can connect a separate main switch to the heater and a 20A time delay fuse near the battery there is a 20A main time delay fuse F1 on the circuit board Be careful not to connect the wires wrong This would melt the 7 5A fuse F2 which protects the electronics Connect the thermostat s sensor ...

Страница 4: ...ifreeze for diesel engines to the fuel If you don t use the heater in the winter and store it in a cold place use paraffin oil the last time you use the heater and leave the fuel hoses full paraffin oil has a low cloud point Paraffin oil will protect the hose from freeze CONTROLLING THE HEATER AND INDICATOR LEDS Basic control panel Start turn the switch to position HEAT ON Ventilation turn the swi...

Страница 5: ... or the temperature Choose menu items with arrow keys accept with OK If you desire extra strong ventilation choose DRYING VENTILATE On this mode the heater takes more fresh air this improves the drying effect while the heating power is low practical f ex in the summer when the air is damp but not very cold Return to the main menu with BACK NB All selections are not allowed in every mode STARTING T...

Страница 6: ...ion the error code on the circuit board display is 3 NB If you have turned off the heater after some malfunction you can see the latest error code on the display again by turning the switch to the position VENT the number of the latest malfunction which caused the heater to turn off shows on the display ERROR CODE NUMBERS ON THE CIRCUIT BOARD DISPLAY Number 1 Overheating Overheating is usually cau...

Страница 7: ...ith the 3600Di heater is180 pulses min and 50 pulses min on minimum power 3200Di heater is 160 pulses min and 50 pulses min on minimum power 2600Di heater is 130 pulses min and 50 pulses min on minimum power with the 2400Di heater 120 pulses min on maximum power and 50 pulses min on minimum power If the heater gets too much fuel the combustion may be impure and cause risk of overheating If the ove...

Страница 8: ...an and then scraping it off f ex with a screwdriver 8 If necessary change the backing 6 The backing stays on its place with a locking spring 7 9 Assemble in an opposite order Make sure that the burner is on its place in a right position Use the glow plug to align the burner Check also the position of the casing pipe of the fuel pipe CLEANING THE FLAME SENSOR ELECTRODE Error code number 2 in the ci...

Страница 9: ...n anti freeze for gasoline engines and truck air brakes through the pump OPENING AND CLEANING THE PUMP 1 Release the hose connectors from the pump 2 Release the wires from the pump 3 Remove the connector strip 8 so that it rests on the filaments of the spool 4 Unscrew the iron housing 1 of the pump and remove it 5 Pull the upper end 3 of the pump out of the spool 4 the piston 9 and the spring 10 a...

Отзывы: