SAFIRE 2400Di, 2600Di, 3200Di and 3600Di Diesel / fuel oil heaters
1
USAGE, INSTALLATION AND MAINTENANCE
January 2012
SF - Lämmitin Oy
Tilhenkatu 1 20610 Turku Finland Puh./Fax +358(0)2-2443282
1
!
A heater kit contains:
• Heater, mounting bracket
• Fuel hose (3 meters), pump, a fuel tank connection to a standard tank (30 litres)
• Power supply cable (4 meters), control panel cable (10 meters)
• Mounting screws, clamps
• Accessories indicated on the package: Control panel or GENIUS control panel, temperature sensor for the
thermostat, exhaust outlet through the hull.
PLACING THE HEATER
Place the heater so that at least a part of the air to be warmed can be taken outside. This will allow good
ventilation and drying effect.
When choosing a place for the heater remember that warm air hoses placed outside the heated space will
lose plenty of heat. Minimize their length and isolate them carefully. It is more economic to place the heater
close to the space to be heated and use a separate fresh air inlet. You don’t have to isolate the warm air
hoses inside (f. ex. under the bed); the hoses function as “radiators” for they dry the space and balance the
temperature differences.
Remember also that as the heater blows warm air inside, an equivalent amount of air must be let out f. ex.
through a ventilator or return to the heater as circulating air.
Maintenance is usually easiest to perform when the heater is removed from its bracket. If the heater is
examined on its place, place the heater so that the led indicators near the fresh air inlet and the control
display are in sight.
Place the heater so that the heater is above the tank’s fuel level. The heater will however not be damaged if
the filler hole of the tank and thereby the fuel level temporarily rises above the heater.
The fuel hose can be lengthened between the pump and the tank.